1. Counting small separated components
A feeder can position the sensor and a reflector across a component transfer path so each separated opaque part interrupts the laser beam. The 1 mm spot at 500 mm defines a local detection point, while a single teach-in button sets sensitivity. Complementary PNP outputs deliver the light and dark states to the machine counter.
Problem Solved
A defined laser detection point isolates component passages, providing an electrical count event when each separated part crosses the monitored position without touching the moving material.
Ø 1 mm at 500 mm
PNP
Teach-in
2. Monitoring accumulation at a transfer point
At a conveyor transfer, a load that remains between the sensor and reflector holds the received-light signal in the blocked state. The machine controller can use this duration to identify sustained occupancy and regulate upstream release. Complementary PNP outputs provide light and dark switching signals, while the M8 4-pin connector connects the sensor to local machine wiring.
Problem Solved
A sustained beam blockage identifies a transfer position that remains occupied, helping the controller coordinate upstream feeding before additional loads enter the same constrained space.
Complementary PNP
M8 4-pin connector
Beam interruption
3. Checking opaque sheet continuity
An opaque sheet feeder can direct the returned beam through the expected material path. The sensor detects whether the material continues to block that path, and an opening caused by runout or a break changes its switching state. IP67 protection suits exposed machine mounting, while the visible red beam assists positioning during initial setup.
Problem Solved
A change in the received-light state gives the controller an electrical indication of missing material at the monitoring position, supporting an orderly response to interrupted feed.
IP67
Visible red light
Material continuity