SICK 6063337 GLL170-N332 NPN Fiber-Optic Amplifier

USD 67.34

GLL170-N332 offers NPN fiber-optic amplification, 250 µs response, 2 kHz switching, adjustable 0–40 ms off delay and a 2 m cable in an IP66 housing.

SKU SICK-6063337 Category
SICK GLL170

SICK GLL170-N332 NPN Fiber-Optic Amplifier

BrandSICK
Model IdentifierGLL170-N332
Official Part Number6063337

Technical Overview

The SICK GLL170-N332 is a stand-alone fiber-optic amplifier with one NPN digital output and a 632 nm visible red LED. The connected optical fiber cable defines the sensing principle and available range, allowing the sensing head to be placed at the monitored point. Potentiometer and rotary controls set the sensing condition, light/dark switching and optional 0–40 ms off delay. Green and yellow LEDs indicate operation, threshold proximity and digital-output state. A response of no more than 250 µs, 2 kHz switching, 10–30 V DC operation, a 2 m three-wire cable and an IP66 PC/POM housing support machine integration.

Stand-alone NPN fiber-optic amplifier with 250 µs response, 2 kHz switching, rotary adjustment, optional 0–40 ms off delay and IP66 housing.

Key Features

  • Stand-alone fiber-optic amplifier with one NPN output
  • Sensing principle and range depend on connected optical fiber
  • 632 nm visible red LED; LED free risk group
  • Potentiometer adjustment for sensing range
  • Light/dark switching selected via rotary control
  • Response ≤250 µs; 2 kHz switching
  • Optional off delay, 0–40 ms selected via rotary switch
  • Green operating/threshold indicator and yellow output LED
  • 10–30 V DC; ≤30 mA without load; output ≤100 mA
  • 2 m three-wire PVC cable; IP66 PC/POM housing

Bring a compatible fiber head to the sensing point and adjust the threshold, light/dark output logic and off delay at the IP66 amplifier.

Technical Specification Matrix

ParameterValue
Functional principleFiber-optic amplifier; stand-alone
Sensing principle and rangeDependent on the optical fiber cable used
Light sourceLED, visible red light
Wavelength632 nm
LED risk groupFree group, EN 62471:2008-09 / IEC 62471:2006 modified
AdjustmentPotentiometer/rotary controls for sensing range, switching mode and off delay
DisplayGreen operating LED dims within ±10% of switching threshold; yellow LED indicates digital-output state
Digital output1 × NPN, selectable via rotary switch
Switching modeLight/dark switching
NPN signal voltage HIGH/LOWApproximately supply voltage / <1.5 V
Output current≤100 mA
Output protectionReverse polarity, overcurrent and short-circuit protected
Response time≤250 µs
Switching frequency2 kHz
Time functionsNo delay or off delay
Delay time0–40 ms, selectable via rotary switch
Power supply10–30 V DC; limit values
Residual ripple≤10%; remain within supply-voltage limits
Current consumption≤30 mA without load
Protection classIII
Connection3-wire, 2 m PVC cable; do not bend below 0 °C
Conductor cross-section0.2 mm²
Cable diameterØ3.8 mm
Housing formRectangular
Housing materialPC/POM plastic
IP ratingIP66, EN 60529
Fixing-screw tightening torqueMaximum 0.5 Nm
Operating temperature−25 to +55 °C
Storage temperature−40 to +70 °C
Relative humidity35–95%, no condensation
Ambient light immunityArtificial light ≤5,000 lx; sunlight ≤60,000 lx
Shock resistance50 g, 11 ms, 18 shocks across X/Y/Z axes; EN 60068-2-27
Vibration resistance10–55 Hz, 1 mm amplitude, 3 ×30 min; EN 60068-2-6
Electromagnetic compatibilityEN 60947-5-2
UL fileNRKH2.E300503 and NRKH8.E300503
MTTFD760 years
Diagnostic coverage DCavg0%
Mission time20 years
Dimensions L x W x H (cm)7.25 x 1 x 3.17
Physical Weight (kg)0.063

Industrial Applications

1. Counting separated components through a fiber beam

A feeder can use a compatible through-beam fiber arrangement across the component path, with the amplifier evaluating the optical signal. Each separated opaque component interrupts the beam and changes the NPN output state. The response of no more than 250 µs and 2 kHz switching frequency define transition timing for the connected machine counter.

Problem Solved

Fiber-guided detection brings the sensing point into a constrained component path, supplying count events while the amplifier remains accessible for threshold and output-mode adjustment.

Fiber-dependent optics NPN 2 kHz

2. Checking a part in a confined fixture

An assembly fixture can place a compatible reflective fiber head near the expected part position while mounting the amplifier in an accessible machine area. The connected fiber establishes the sensing geometry, and the potentiometer sets the detection condition. Green and yellow LEDs provide operating and output indications while the NPN signal reports presence.

Problem Solved

Separating the fiber head from the amplifier supports a local presence check in a confined fixture while retaining accessible controls and visible operating indications outside the detection point.

Remote fiber head Potentiometer NPN

3. Bridging brief interruptions in sheet feed

A sheet feeder can use a compatible fiber arrangement to monitor material in a narrow feed path. The amplifier evaluates the optical state and applies the optional off delay so brief gaps do not immediately release the NPN signal. A sustained absence allows the selected 0–40 ms delay to expire and changes the controller input.

Problem Solved

A short maintained output bridges brief gaps in material presentation, helping the controller distinguish transient interruptions from sustained feed loss at the monitored sheet path.

Off delay 0–40 ms NPN