1. Counting separated cartons
A carton conveyor can mount the sender on one side and the receiver on the opposite side so each opaque carton interrupts the optical path. The documented 0–10 m sensing range supports the installed separation, while complementary NPN outputs report the received-light states. The 1,000 Hz switching frequency supports repeated carton transitions within the specified timing limits.
Problem Solved
Each separated carton passage produces a discrete electrical event without contact, supplying a counter input while the optical path spans the conveyor between two fixed mounting points.
Through-beam
0–10 m
NPN
2. Monitoring load accumulation at a transfer
A transfer conveyor can place the through-beam path across a position where an opaque load remains when downstream handling pauses. Sustained beam blockage holds the receiver in the object-present condition. Complementary NPN light/dark outputs provide the controller signal, and M18 threaded housings support the sender and receiver mounting arrangement.
Problem Solved
A sustained interruption identifies an occupied transfer position, helping the controller coordinate upstream release before more loads enter the same constrained space during normal production.
Complementary NPN
M18 × 1
Beam interruption
3. Checking opaque sheet continuity
A sheet feeder can direct the optical path through the expected material route so an opaque sheet normally blocks the received beam. A break or runout restores received light and changes the complementary NPN signals. The potentiometer sets reception for the installed sender–receiver spacing, while IP67 protection supports exposed machine mounting.
Problem Solved
A changed light state gives the controller an electrical indication of missing material at the monitored point, supporting a coordinated response to interrupted sheet feed.
Through-beam
IP67
Material continuity