SICK 1066556 GRL18-P1132 PNP Retro-Reflective Sensor

USD 55.90

GRL18-P1132 provides complementary PNP outputs, 0.06–6 m sensing with PL80A, 1,000 Hz switching, a metal M18 housing and a 2 m cable.

SKU SICK-1066556 Category
SICK GR18

SICK GRL18-P1132 PNP Retro-Reflective Sensor

BrandSICK
Model IdentifierGRL18-P1132
Official Part Number1066556

Technical Overview

The SICK GRL18-P1132 is a cylindrical retro-reflective photoelectric sensor with complementary PNP outputs and axial optics. Its dual-lens arrangement requires a minimum reflector distance. With a PL80A reflector, the specified sensing range is 0.06–6 m and the maximum range is 0.03–7.2 m. A 650 nm visible red PinPoint LED produces a 175 mm spot at 7 m, while a potentiometer adjusts reception. Response below 500 µs and 1,000 Hz switching support repeated transitions. The M18 × 1 nickel-plated brass/ABS housing, 2 m four-wire cable, two supplied fastening nuts and IP67 protection support machine installation.

PNP dual-lens retro-reflective sensor with 0.06–6 m sensing using PL80A, complementary outputs, M18 mounting and 2 m cable.

Key Features

  • Dual-lens retro-reflective photoelectric sensing
  • Minimum reflector distance required
  • 0.06–6 m sensing range with PL80A reflector
  • 0.03–7.2 m maximum range with PL80A reflector
  • 650 nm PinPoint LED; Ø175 mm spot at 7 m
  • Axial optics; M18 × 1 cylindrical mounting
  • Potentiometer adjustment; complementary PNP outputs
  • Response <500 µs; 1,000 Hz switching
  • 2 m four-wire PVC cable; two fastening nuts supplied
  • IP67 nickel-plated brass/ABS housing with PMMA optics

Detect beam interruptions with a passive PL80A reflector and complementary PNP outputs while keeping electrical wiring on the sensor side.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor; dual-lens system with minimum reflector distance
Sensing range0.06–6 m with PL80A reflector
Maximum sensing range0.03–7.2 m with PL80A reflector
Light sourcePinPoint LED, visible red light
Wavelength650 nm
Light spot sizeØ175 mm at 7 m
AdjustmentPotentiometer
Optical axisAxial
Housing formCylindrical, M18 × 1 thread
Power supply10–30 V DC; short-circuit-protected network max. 8 A
Residual ripple<5 Vpp; remain within supply-voltage limits
Current consumption30 mA
Switching outputPNP, complementary
Switching modeLight/dark switching
Output current≤100 mA; maximum 50 mA at supply >24 V or ambient temperature >49 °C
Response time<500 µs with resistive load
Switching frequency1,000 Hz at light/dark ratio 1:1
Connection4-wire, 2 m PVC cable; do not bend below 0 °C
Circuit protectionSupply/input/output reverse-polarity protection and output overcurrent/short-circuit protection
Protection classIII
Housing materialMetal, nickel-plated brass and ABS
Optics materialPMMA plastic
IP ratingIP67
Items supplied2 fastening nuts
Operating temperature−25 to +55 °C at supply ≤24 V and output current <50 mA
Storage temperature−40 to +70 °C
Electromagnetic compatibilityEN 60947-5-2
UL fileE348498
Dimensions L x W x H (cm)7.15 x 1.8 x 1.8
PNP signal voltage HIGH/LOWSupply voltage − (≤3 V) / approximately 0 V

Industrial Applications

1. Counting separated opaque cartons

A carton conveyor can place the sensor on one side and a passive reflector on the other. Each opaque carton interrupts the returned red beam, producing a PNP switching event for the counter. Retro-reflective sensing provides the optical path, while the 1,000 Hz switching frequency supports repeated transitions within the specified timing limits.

Problem Solved

The reflector needs no electrical supply, reducing wiring across the conveyor while the machine receives a discrete event for each separated carton that interrupts the beam.

Retro-reflective PNP 1,000 Hz

2. Monitoring accumulation at a transfer point

At a conveyor transfer, a load that remains between the sensor and reflector holds the received-light signal in the blocked state. The machine controller can use this duration to identify sustained occupancy and regulate upstream release. Complementary PNP outputs provide light and dark switching signals, while the 2 m four-wire cable connects the sensor to local machine wiring.

Problem Solved

A sustained beam blockage identifies a transfer position that remains occupied, helping the controller coordinate upstream feeding before additional loads enter the same constrained space.

Complementary PNP 2 m four-wire cable Beam interruption

3. Checking opaque sheet continuity

An opaque sheet feeder can direct the returned beam through the expected material path. The sensor detects whether the material continues to block that path, and an opening caused by runout or a break changes its switching state. IP67 protection suits exposed machine mounting, while the visible red beam assists positioning during initial setup.

Problem Solved

A change in the received-light state gives the controller an electrical indication of missing material at the monitoring position, supporting an orderly response to interrupted feed.

IP67 Visible red light Material continuity
Select your currency