SICK 6013540 VL18-4N3212 NPN Retro-Reflective Sensor

USD 105.56

VL18-4N3212 offers NPN retro-reflective sensing, 0.05–3 m range with C110A, 270° adjustment, 250 Hz switching, M18 mounting and a 2 m cable.

SKU SICK-6013540 Category
SICK V18

SICK VL18-4N3212 NPN Retro-Reflective Sensor

BrandSICK
Model IdentifierVL18-4N3212
Official Part Number6013540

Technical Overview

The SICK VL18-4N3212 is a cylindrical retro-reflective photoelectric sensor with an NPN output and axial optics. A passive C110A reflector returns the optical beam, allowing opaque targets to be detected when they interrupt that path. With this reflector, the specified sensing range is 0.05–3 m and the maximum range is 0.05–3.7 m. The visible red LED forms a 150 mm spot at 3 m, and a 270° potentiometer adjusts sensitivity. An L/D control connection selects switching logic. Response of no more than 2 ms, 250 Hz switching, a 2 m cable and IP67 nickel-plated brass housing support machine integration.

NPN retro-reflective sensor with 0.05–3 m sensing using C110A, 270° sensitivity adjustment, selectable L/D logic, M18 housing and 2 m cable.

Key Features

  • Retro-reflective photoelectric sensing
  • 0.05–3 m sensing range with C110A reflector
  • 0.05–3.7 m maximum range with C110A reflector
  • Visible red LED; Ø150 mm spot at 3 m
  • 270° sensitivity potentiometer
  • NPN output; L/D control connection selects light/dark logic
  • Open control connection: light switching
  • Response ≤2 ms; 250 Hz switching
  • Axial M18 × 1 nickel-plated brass housing; IP67
  • 2 m four-wire PVC cable; 10–30 V DC operation

Monitor beam interruptions with a passive C110A reflector while keeping the sensor’s electrical connection on one side of the machine.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor
Sensing range0.05–3 m with C110A reflector
Maximum sensing range0.05–3.7 m with C110A reflector
Light sourceLED, visible red light
Light spot sizeØ150 mm at 3 m
Angle of dispersionApproximately 2.8°
AdjustmentPotentiometer, 270°, for sensitivity
Optical axisAxial
Housing formCylindrical, M18 × 1
Power supply10–30 V DC; limit values
Residual ripple±10%; remain within supply-voltage limits
Current consumption30 mA without load
Switching outputNPN
Switching modeLight/dark switching, selectable via L/D control connection; control connection open = light switching L.ON
Output current≤100 mA
Response time≤2 ms with resistive load
Switching frequency250 Hz at light/dark ratio 1:1
Connection4-wire, 2 m PVC cable; do not bend below 0 °C
Circuit protectionSupply/input/output reverse-polarity protection, interference suppression and output overcurrent/short-circuit protection
Protection classIII
Housing materialMetal, nickel-plated brass
Optics materialPMMA plastic
IP ratingIP67
Operating temperature−25 to +70 °C
UL fileNMFT2.E175606
Conductor cross-section0.14 mm²
Cable diameterØ5 mm
Dimensions L x W x H (cm)6.36 x 1.8 x 1.8
Physical Weight (kg)0.12
MTTFD68 years
Diagnostic coverage DCavg0%

Industrial Applications

1. Counting separated opaque cartons

A carton conveyor can place the sensor on one side and a passive reflector on the other. Each opaque carton interrupts the returned red beam, producing a NPN switching event for the counter. Retro-reflective sensing provides the optical path, while the 250 Hz switching frequency supports repeated transitions within the specified timing limits.

Problem Solved

The reflector needs no electrical supply, reducing wiring across the conveyor while the machine receives a discrete event for each separated carton that interrupts the beam.

Retro-reflective NPN 250 Hz

2. Monitoring accumulation at a transfer point

At a conveyor transfer, a load that remains between the sensor and reflector holds the received-light signal in the blocked state. The machine controller can use this duration to identify sustained occupancy and regulate upstream release. The L/D control connection selects light or dark switching, while the 2 m four-wire cable connects the sensor to local machine wiring.

Problem Solved

A sustained beam blockage identifies a transfer position that remains occupied, helping the controller coordinate upstream feeding before additional loads enter the same constrained space.

Selectable L/D 2 m four-wire cable Beam interruption

3. Checking opaque sheet continuity

An opaque sheet feeder can direct the returned beam through the expected material path. The sensor detects whether the material continues to block that path, and an opening caused by runout or a break changes its switching state. IP67 protection suits exposed machine mounting, while the visible red beam assists positioning during initial setup.

Problem Solved

A change in the received-light state gives the controller an electrical indication of missing material at the monitoring position, supporting an orderly response to interrupted feed.

IP67 Visible red light Material continuity
Select your currency