SICK 1055459 IQ10-06NNSKW2S NPN Rectangular Inductive Sensor

USD 37.96

IQ10-06NNSKW2S offers 6 mm nominal metal sensing, NPN NO output, 2,000 Hz switching, a 2 m cable and an IP68 VISTAL rectangular housing.

SKU SICK-1055459 Category
SICK IQB

SICK IQ10-06NNSKW2S NPN Rectangular Inductive Sensor

BrandSICK
Model IdentifierIQ10-06NNSKW2S
Official Part Number1055459

Technical Overview

The SICK IQ10-06NNSKW2S is a rectangular inductive proximity sensor with an NPN normally open output and DC three-wire wiring. It detects metal targets without an optical path, with a nominal sensing range of 6 mm and an assured range of 4.86 mm. The actual target material must be considered using the documented reference reduction factors. Non-flush installation requires clearance around the sensing area, while the 10 × 28 × 16 mm VISTAL housing supports compact machine layouts. The sensor provides 2,000 Hz switching and operates from 10–30 V DC, with a 2 m PVC cable and IP68 protection.

Rectangular inductive sensor with 6 mm nominal range, NPN NO output, 2,000 Hz switching, 2 m cable and IP68 VISTAL housing.

Key Features

  • Inductive metal detection in a rectangular VISTAL housing
  • 6 mm nominal range; 4.86 mm assured range
  • Non-flush installation
  • NPN normally open output; DC three-wire wiring
  • 2,000 Hz switching frequency
  • 10–30 V DC operation; 10 mA no-load current
  • Continuous output current ≤200 mA; voltage drop ≤3 V
  • 2 m PVC cable; 0.25 mm² conductors
  • IP68 according to EN 60529; −25 to +75 °C operation
  • Maximum tightening torque ≤1 Nm

Fit non-flush metal detection into a compact rectangular mounting space with a 6 mm nominal range and NPN normally open output.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing of metal targets
Housing formRectangular
Nominal sensing range Sn6 mm
Assured sensing range Sa4.86 mm
Installation typeNon-flush
Switching frequency2,000 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC 3-wire
ConnectionCable, 3-wire, 2 m
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤3 V at maximum output current
Time delay before availability≤100 ms
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply and ambient temperature
Temperature drift±10% of Sr
Continuous output current≤200 mA
No-load current10 mA
Housing materialVISTAL plastic
Sensing face materialVISTAL plastic
Maximum tightening torque≤1 Nm
IP ratingIP68 according to EN 60529
Operating temperature−25 to +75 °C
EMCEN 60947-5-2
Shock and vibration resistance30 g, 11 ms / 10–55 Hz, 1 mm
Reference material reduction factorsStainless steel V2A/304: 0.7; aluminum: 0.5; copper: 0.35; brass: 0.5; reference values may vary
MTTFD1,730 years
Diagnostic coverage DCavg0%
Cable jacket materialPVC
Conductor cross-section0.25 mm²
Cable diameterØ3.7 mm
Mission time TM20 years
Dimensions L x W x H (cm)1.6 x 1 x 2.8

Industrial Applications

1. Confirming a metal part in a fixture

A machining fixture can place the sensor beside the expected location of a metal part so the target enters its assured sensing zone when seated. Non-flush installation requires the sensing end to project beyond the surrounding mounting surface, and the NPN normally open output provides the presence signal. Target material must be considered using the documented reduction factors.

Problem Solved

A contactless metal-presence signal helps the sequence controller identify an occupied fixture position before the next operation, avoiding a mechanical feeler pressing against the seated part.

Non-flush mounting NPN NO Metal presence

2. Counting metal tabs on a rotating mechanism

A rotating mechanism can present separated metal tabs to the rectangular sensing face and count each normally open output transition. The 2,000 Hz switching frequency supports repeated passages within the documented limits. Tab geometry, spacing, operating gap and material reduction factors must be qualified so consecutive targets produce distinct switching events.

Problem Solved

Discrete tab passages provide the controller with a pulse count related to mechanism rotation, supporting cycle counting without an optical beam or contacting follower on the moving tabs.

2,000 Hz Inductive NPN NO

3. Confirming a shuttle at a transfer position

A shuttle can carry a metal flag that enters the sensor’s local detection zone at a transfer position. The compact rectangular housing supports installation beside the travel path, while the normally open NPN signal reports the flag state. IP68 protection and the VISTAL housing support exposed machine placement within the documented ambient limits.

Problem Solved

A local position-confirmation signal helps the controller coordinate transfer sequencing when the metal flag reaches the monitored point, without a mechanical switch actuator following each shuttle movement.

Compact rectangular housing IP68 Metal flag