SICK 6026195 CM18-08BPP-TW0 PTFE PNP Capacitive Sensor

USD 169.78

CM18-08BPP-TW0 offers M18 × 1 flush capacitive sensing, complementary PNP operation, 3–8 mm specified range and 270° sensitivity potentiometer adjustment.

SKU SICK-6026195 Category
SICK CM PTFE

SICK CM18-08BPP-TW0 PTFE PNP Capacitive Sensor

BrandSICK
Model IdentifierCM18-08BPP-TW0
Official Part Number6026195

Technical Overview

The SICK CM18-08BPP-TW0 is a flush-mount capacitive proximity sensor with an M18 × 1 threaded housing and complementary PNP operation. It detects nearby material through changes in capacitance, supporting qualified metal and nonmetal targets. Its specified sensing range is 3–8 mm, with actual reach dependent on material and installation. The 270° sensitivity potentiometer adapts detection sensitivity. The sensor operates from 10–36 V DC at 30 Hz and connects through a 2 m four-wire PVC cable. Its PTFE-coated housing provides IP67 protection according to EN 60529, and two mounting nuts plus a screwdriver are supplied. Material reduction factors guide application setup.

M18 × 1 flush capacitive sensor with complementary PNP operation, 3–8 mm specified sensing range, 270° sensitivity potentiometer and 2 m four-wire PVC cable.

Key Features

  • Capacitive proximity detection of qualified metal and nonmetal materials
  • M18 × 1 threaded housing for flush installation
  • 3–8 mm specified range; material-dependent detection distance
  • Complementary pnp operation
  • 270° sensitivity potentiometer
  • 10–36 V DC supply; 30 Hz switching
  • 2 m four-wire pvc cable
  • IP67 according to EN 60529; PTFE-coated housing
  • Two mounting nuts and one potentiometer screwdriver included

Mount flush using the M18 × 1 threaded housing and adjust capacitive detection for qualified metal or nonmetal targets with complementary PNP operation.

Technical Specification Matrix

ParameterValue
Functional principleCapacitive proximity sensing
Housing designMetric threaded housing
Thread sizeM18 × 1
Housing diameter18 mm
Sensing range3–8 mm
Assured sensing distance5.76 mm
InstallationFlush
Switching frequency30 Hz
Electrical wiringDC, 4-wire
Switching outputComplementary pnp
Output functionComplementary NO and NC
Adjustment270° sensitivity potentiometer
Material reduction factorsReference values, material dependent: metal 1; water 1; PVC approximately 0.4; oil approximately 0.25; glass 0.6; ceramics 0.5; alcohol 0.7; wood 0.2–0.7
Power supply10–36 V DC
Residual ripple≤10% of supply voltage
Current consumption10 mA without load
Initialization time≤100 ms
Hysteresis4–20% of sensing range
Reproducibility≤5% of sensing range at constant supply voltage and ambient temperature
Temperature drift±10% of sensing range
EMCEN 60947-5-2; conducted interference in the oscillator frequency range may change the output signal; observe manufacturer operating instructions
Output current≤200 mA
Connection2 m four-wire pvc cable
Cable materialPVC; do not bend below 0 °C
Conductor cross-section0.34 mm²
Power-up pulse suppressionYes
Shock resistance30 g for 11 ms
Vibration resistance10–55 Hz at 1 mm amplitude
Operating temperature−25 to +60 °C
Housing materialPTFE coating, PTFE
Housing length71.5 mm
Thread length46.5 mm
Maximum tightening torque≤2.6 Nm
IP ratingIP67 according to EN 60529
Items suppliedTwo PTFE plastic mounting nuts and one potentiometer screwdriver
IndicatorDisplay LED
MTTFD897 years
Diagnostic coverage DCavg0%
Mission time20 years
Voltage drop≤2.5 V DC at maximum output current
Short-circuit protectionYes
Wire assignmentBN: L+; BK: NO; WH: NC; BU: M

Industrial Applications

1. Checking a nonmetal part in an assembly fixture

An assembly fixture can place a qualified nonmetal part near the sensing face and use the complementary PNP signal to confirm its local presence. The 270° sensitivity potentiometer adapts sensitivity to the actual target and surrounding fixture. Commissioning compares empty and occupied states at the installed spacing, taking the documented material reduction factors into account.

Problem Solved

A local presence signal helps the controller detect a missing part before the next assembly step, without requiring a metal target on the component or a contact actuator.

Part presence Nonmetal targets Capacitive sensing

2. Detecting a liquid at a point in a nonmetal vessel

A suitable nonmetal vessel can position the sensor outside its wall at the desired detection point. After testing the actual wall, liquid and spacing, the 270° sensitivity potentiometer sets a threshold between empty and filled conditions. The complementary PNP output provides a discrete point-level event to a compatible controller; the specified range remains subject to the installed materials.

Problem Solved

A qualified external point-level signal helps the process controller identify liquid reaching the monitored height while avoiding a probe inside the vessel and preserving the vessel wall.

Point level External mounting Qualified vessel wall

3. Monitoring granulate at a feed inspection window

A granulate feeder can place the sensor beside a suitable nonmetal inspection window to check whether material occupies the monitored location. The 270° sensitivity potentiometer is set using the actual granulate, window and installation spacing. Empty and filled tests, including expected moisture and buildup conditions, qualify the discrete output before it is used to coordinate feeding.

Problem Solved

A local material-presence event helps the controller identify an empty feed location or arrival of replenishment material, supporting feed sequencing without placing a mechanical paddle in the granulate.

Granulate feed Material presence Threshold setup
Select your currency