Contact Us:
sales@inosaki.com

WFS3-40B41CA70 Fork Sensors – SICK Sensor

$ 165.22

SKU SICK 6058650 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6058650
Fork Sensor Model: WFS3-40B41CA70
OEM Spec Ref 

Features

Functional principle Optical detection principle
Dimensions (W x H x D) 10 mm x 25 mm x 64.3 mm
Housing design (light emission) Fork shaped
Fork width 3 mm
Fork depth 42 mm
Minimum detectable object (MDO) Gap between Labels / Size of labels: 2 mm 1)
Label detection
Light source LED, Infrared light
Adjustment Teach-in button (Teach-in, sensitivity, light/dark switching, key lock)

Cable (Teach-in dynamic)

Teach-in mode 1-point teach-in

2-point teach-in

Teach-in dynamic

  • 1) Depends on the label thickness.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 10 % 2)
Current consumption 20 mA 3)
Switching frequency 15 kHz 4)
Response time 46 µs 5)
Stability of response time ± 20 µs
Jitter 17 µs
Switching output Push-pull: PNP/NPN
Switching output (voltage) Push/Pull: High = VS – < 2 V / Low: ≤ 2 V
Switching mode Light/dark switching
Output current Imax. 100 mA
Input, teach-in (ET) Teach: U > 5 V … < UV

Run: U < 4 V

Initialization time 40 ms
Time delay Switch-off delay, 0 ms / 8 ms / 16 ms / 32 ms / 65 ms / 130 ms / 260 ms / 520 ms, adjustable (0 ms = default)
Connection type Male connector M8, 4-pin
Protection class III
Circuit protection UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure rating IP65
Weight Approx. 36 g
Housing material Plastic, PA (glass-fiber reinforced)
  • 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) With light/dark ratio 1:1, typical, during teach-in 6 kHz.
  • 5) Signal transit time with resistive load.

Additional information

Related Products

Festo_Proximity sensors_SMT-10M-NS-24V-E-03-L-M8D_551379
IDS_Camera_uEye+_LE_VU_AF_BoardLevel_C_Mount_1
IDS_camera_GV-5990FA-1
Omron_Programmable Relay_ZEN-10C4AR-A-V2
SICK_sensor_Photoelectric_sensor_V12-2_VL12-2N132
Phoenix_Contact_Fixed_Bridge_FBI 10- 6_0203250
Select your currency