SICK 6055434 WFS3-40N115 NPN Label Fork Sensor

USD 111.02

Infrared label detection with a 3 mm fork, 42 mm depth, NPN output, two-point/dynamic teaching, 10 kHz switching and a 2 m four-wire cable.

SKU SICK-6055434 Category
SICK WFS

SICK WFS3-40N115 NPN Infrared Label Fork Sensor

BrandSICK
Model IdentifierWFS3-40N115
Official Part Number6055434

Technical Overview

The SICK WFS3-40N115 is an infrared optical fork sensor for label and carrier-gap detection with an NPN switching output. Its 3 mm fork opening and 42 mm fork depth support installation around a guided label web. The minimum label size and gap are 2 mm, depending on label thickness. Two-point or dynamic teaching and plus/minus sensitivity adjustment adapt the detection threshold and light/dark switching. The sensor combines 10 kHz switching, response no greater than 50 µs, a 2 m four-wire cable and an IP65 glass-fiber-reinforced PA housing for machine integration.

Infrared label fork sensor with 3 mm opening, 42 mm depth, NPN output and two-point/dynamic teaching, 10 kHz switching and 2 m four-wire cable.

Key Features

  • Infrared LED optical label and carrier-gap detection
  • 3 mm fork opening and 42 mm fork depth
  • Minimum label size/gap 2 mm, depending on label thickness
  • Two-point and dynamic teach-in with plus/minus adjustment
  • NPN output with light/dark switching
  • 20 ms initialization; 20 mA no-load consumption
  • 10 kHz switching; response ≤50 µs and ±20 µs response-time stability
  • 2 m four-wire cable
  • 10–30 V DC operation; maximum output current 100 mA
  • IP65 glass-fiber-reinforced PA housing; −20 to +60 °C operation

Teach the optical distinction between label and carrier, then adjust sensitivity with plus/minus controls and supply an NPN feed-reference signal.

Technical Specification Matrix

ParameterValue
Functional principleOptical label and carrier-gap detection
Light sourceLED, infrared light
Label detectionYes
Fork opening3 mm
Fork depth42 mm
Minimum detectable objectLabel gap / label size: 2 mm, depending on label thickness
AdjustmentPlus/minus buttons and cable; teaching, sensitivity and light/dark switching
Teach-in modeTwo-point and dynamic teach-in
IndicatorsYellow switching-output/function LED; red function LED
Power supply10–30 V DC
Residual ripple<10%
Current consumption20 mA without load
Initialization time20 ms
Switching frequency10 kHz
Response time≤50 µs
Response-time stability±20 µs
Jitter40 µs
Switching outputNPN
Switching modeLight/dark switching
Output current100 mA maximum
Teach inputNPN; teach: U<(supply voltage −6 V); run: U>(supply voltage −5 V)
Protection classIII
Circuit protectionSupply reverse-polarity protection, output Q short-circuit protection and interference-pulse suppression
Connection2 m four-wire cable
Pin assignmentBN: L+; WH: teach; BU: M; BK: Q
Housing materialGlass-fiber-reinforced PA
IP ratingIP65
Operating temperature−20 to +60 °C
Storage temperature−30 to +80 °C
Ambient light immunity≤10,000 lx
Shock resistanceAccording to EN 60068-2-27
MTTFD97 years
Diagnostic coverage DCavg0%
UL fileNRKH.E191603
Dimensions L x W x H (cm)6.43 x 1 x 2.5
Output voltageNPN HIGH approximately supply voltage; LOW ≤2 V

Industrial Applications

1. Registering a label feed at the dispenser

A label applicator can guide its web through the 3 mm fork opening near the dispensing point and use each label-to-carrier transition as a feed reference. Teaching sets the optical threshold for the selected label stock. The 42 mm fork depth and thickness-dependent 2 mm minimum label/gap specification define the mechanical and material limits for this installation.

Problem Solved

A qualified label transition supplies a feed-position reference to the machine controller, helping align each dispensing cycle with the next label while the web remains mechanically guided.

Label registration 3 mm opening 10 kHz

2. Counting labels during a roll transfer

A roll-transfer machine can route the web through the fork and count one qualified NPN transition per label with an external counter. Two-point or dynamic teaching sets detection for that label stock. The 10 kHz switching frequency, response no greater than 50 µs and minimum label/gap dimensions define the detection timing and target limits.

Problem Solved

Label-passage pulses give the external counter a quantity reference for batch completion and roll reconciliation, avoiding manual counting of labels already wound onto the destination roll.

External label count NPN 10 kHz

3. Flagging an empty label position before application

An inspection station can compare NPN label events with expected pitch windows from the machine controller while the web passes through the optical fork. A missing taught label event in a scheduled window indicates an empty carrier position at that inspection point. Actual label thickness and optical contrast determine whether the stock meets the stated 2 mm label/gap limit.

Problem Solved

Comparing a scheduled label window with the detected event identifies a missing-label position before dispensing, allowing the external controller to mark or reject that cycle in the machine sequence.

Missing-label inspection 2-point / dynamic teach ≤50 µs