SICK 6036832 WFL50-60B416 Laser Fork Sensor

USD 454.22

Laser fork sensor with 50 mm opening, 0.05 mm minimum object, separate PNP/NPN outputs, two-point teach-in, 10 kHz switching and M8 four-pin connector.

SKU SICK-6036832 Category
SICK WFL

SICK WFL50-60B416 Laser Fork Sensor

BrandSICK
Model IdentifierWFL50-60B416
Official Part Number6036832

Technical Overview

The SICK WFL50-60B416 is a visible-red laser fork sensor with a 50 mm opening and 59 mm fork depth. Its specified minimum detectable object is 0.05 mm, supporting detection of small targets crossing the optical axis. Separate PNP and NPN outputs connect through an M8 four-pin male connector. Plus/minus buttons provide two-point teach-in, sensitivity adjustment and selectable light/dark switching, with teaching performed while material is stationary. The sensor offers 10 kHz switching, response no greater than 100 µs and 100 ms initialization. A 10–30 V DC supply, IP65 aluminum housing and −20 to +50 °C operating range define installation conditions.

Visible-red laser fork with 50 mm opening, 59 mm depth, 0.05 mm minimum object, two-point teach-in and separate PNP/NPN outputs.

Key Features

  • Visible-red laser optical detection; laser class 1 per EN/IEC 60825-1:2007
  • 50 mm fork opening; 59 mm fork depth
  • Minimum detectable object 0.05 mm
  • Two-point teach-in at material standstill; plus/minus sensitivity adjustment
  • Separate PNP and NPN outputs; selectable light/dark switching
  • 10 kHz switching; response ≤100 µs; response stability ±20 µs
  • 40 µs jitter; 100 ms initialization
  • 10–30 V DC supply; 40 mA no-load consumption; maximum output current 100 mA
  • M8 four-pin male connector; pin 2 NPN and pin 4 PNP
  • IP65 aluminum housing; −20 to +50 °C operation

Detect small targets in a 50 mm laser fork with adjustable two-point teaching and separate PNP and NPN signals.

Technical Specification Matrix

ParameterValue
Functional principleOptical fork detection
Light sourceLaser, visible red light
Laser class1, according to EN/IEC 60825-1:2007
Fork opening50 mm
Fork depth59 mm
Minimum detectable object0.05 mm
AdjustmentPlus/minus buttons for teach-in, sensitivity and light/dark switching
Teach-in modeTwo-point teach-in; material stationary
Control lockPress both plus/minus buttons for 3 seconds
Switching-mode selectionPress both plus/minus buttons for 6 seconds; standard setting light switching
IndicatorsYellow switching-output indicator; red function indicator
Power supply10–30 V DC
Residual ripple<10%
Current consumption40 mA without load
Initialization time100 ms
Switching frequency10 kHz
Response time≤100 µs
Response-time stability±20 µs
Jitter40 µs
Switching outputSeparate PNP and NPN outputs
NPN output voltageHIGH approximately supply voltage; LOW ≤2 V
Switching modeSelectable light/dark switching
Output current100 mA maximum
Protection classIII; reference voltage DC 50 V
Circuit protectionSupply reverse-polarity protection, output Q short-circuit protection and interference-pulse suppression
ConnectionM8 four-pin male connector
Pin assignment1/BN: L+; 2/WH: QNPN; 3/BU: M; 4/BK: QPNP
Housing materialAluminum
Housing thickness10 mm, excluding connector profile
Mounting holesØ4.2 mm
IP ratingIP65
Operating temperature−20 to +50 °C
Storage temperature−30 to +80 °C
Ambient light immunity≤10,000 lx
Shock resistanceAccording to EN 60068-2-27
MTTFD80 years
Diagnostic coverage DCavg0%

Industrial Applications

1. Counting small components from a feeder

A guided feeder can present individual opaque components across the laser beam within the fork opening. Each qualified interruption provides a switching event to an external counter. The 0.05 mm minimum detectable object, 10 kHz switching frequency and response no greater than 100 µs define relevant selection limits for the target and spacing.

Problem Solved

A noncontact part-passage event lets the external counter track quantities at the feeder exit, avoiding a counting lever touching small components as they move through the monitored point.

Small-part counting 0.05 mm MDO 10 kHz

2. Indexing a carrier with a thin opaque flag

A machine carrier can move an opaque reference flag through the 50 mm opening and across the optical axis at a designated station. Two-point teach-in is performed with the material stationary, followed by sensitivity fine adjustment if needed. The external controller selects a PNP or NPN output and the appropriate switching edge for a discrete position reference.

Problem Solved

The reference flag provides an electrical arrival event for coordinating a station cycle, reducing dependence on a mechanical contact cam at the monitored carrier position.

Carrier indexing 50 mm opening PNP/NPN

3. Checking a small component in an assembly fixture

An assembly fixture can position a seated opaque component so it interrupts the laser at a defined inspection point. Teaching the clear path and target condition with material stationary establishes the switching threshold. The controller then reads the selected light/dark output before advancing the sequence, with the 0.05 mm minimum object specification guiding target qualification.

Problem Solved

The qualified beam state distinguishes a component at the monitored fixture point from a clear path, enabling the external controller to flag a missing component before the next assembly operation.

Fixture presence Two-point teach Light/dark