SICK 1076666 IMF18-12NPSNC0S PNP IO-Link Inductive Sensor

USD 69.94

M18 non-flush inductive sensor with 12 mm nominal range, PNP NO output, IO-Link V1.0, 1,000 Hz switching, stainless steel body and IP68/IP69K protection.

SKU SICK-1076666 Category
SICK IMF

SICK IMF18-12NPSNC0S IO-Link Inductive Sensor

BrandSICK
Model IdentifierIMF18-12NPSNC0S
Official Part Number1076666

Technical Overview

The SICK IMF18-12NPSNC0S is an M18 non-flush inductive proximity sensor for hygienic and washdown zones. It provides a 12 mm nominal sensing range and 9.72 mm assured range, with a normally-open PNP output and 1,000 Hz switching. The stainless steel V4A housing uses DIN 1.4404/AISI 316L, while the sensing face is LCP plastic. Cleaning-agent resistance, IP68/IP69K protection and a −40 to +100 °C operating range support demanding machine environments. IO-Link V1.0 adds one-byte process data indicating whether Sr and Sa are reached. An M12 four-pin connector with gold-plated contacts connects the DC three-wire device to a 10–30 V DC supply.

M18 non-flush inductive sensor with 12/9.72 mm nominal/assured ranges, PNP NO output, IO-Link V1.0, 1,000 Hz switching and IP68/IP69K protection.

Key Features

  • M18 metric housing; non-flush installation
  • 12 mm nominal range; 9.72 mm assured range
  • PNP normally-open output; DC three-wire; 1,000 Hz switching
  • V4A stainless steel housing, DIN 1.4404/AISI 316L; LCP sensing face
  • Resistant to cleaning agents; specified for hygienic and washdown zones
  • IP68 per EN 60529; IP69K per ISO 20653:2013-03
  • −40 to +100 °C ambient operation
  • 10–30 V DC; continuous output current ≤200 mA
  • M12 four-pin male connector with gold-plated contacts
  • IO-Link V1.0, COM2; one-byte process data for Sr/Sa reached states

Monitor metal targets in washdown machinery with a stainless steel inductive sensor, cleaning-agent resistance and IO-Link detection-zone feedback.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical, standard design
Housing diameter18 mm
Housing threadM18 × 1
Sensing range Sn12 mm nominal
Assured sensing range Sa9.72 mm
InstallationNon-flush
Switching frequency1,000 Hz
Switching outputPNP
Output functionNormally open (NO)
Electrical wiringDC three-wire
ConnectionM12 four-pin male connector; gold-plated contacts
Pin assignment1/BN: L+; 4/BK: NO/C (IO-Link); 3/BU: M; 2: not connected
Special featuresCleaning-agent resistance, visual adjustment indicator and temperature resistance
Specified application environmentHygienic and washdown zones; difficult application conditions
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤2 V at maximum output current Ia
Hysteresis3–20%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
EMCAccording to EN 60947-5-2
Continuous output current≤200 mA
No-load current≤10 mA
Circuit protectionShort-circuit and power-up pulse protection
Shock and vibration data100 g / 2 ms / 500 cycles; 150 g / 1 million cycles; 10–55 Hz / 1 mm; 55–500 Hz / 60 g
Operating temperature−40 to +100 °C
Housing materialStainless steel V4A, DIN 1.4404 / AISI 316L
Sensing face materialLCP plastic
Protection classIII
UL fileE181493
MTTFD1,971 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsApproximate reference values, may vary: V2A/304=0.70; aluminum=0.43; copper=0.37; brass=0.43
Mounting clearancesA=18 mm; B=45 mm; C=18 mm; D=36 mm; E=12 mm; F=96 mm; follow manufacturer installation diagram
IP ratingIP68 per EN 60529; IP69K per ISO 20653:2013-03
Items suppliedTwo V4A stainless steel mounting nuts
Visual adjustment indicatorInstallation aid indicating the target zone between Sr and Sa; Sa =0.81 × Sn
Housing length65 mm
Thread length39 mm
IO-LinkV1.0
IO-Link communicationCOM2, 38.4 kBaud
Process data length1 byte
Process data structureBit 0: Sr reached; bit 1: Sa reached

Industrial Applications

1. Confirming a metal carrier at a washdown station

A packaging station can present a qualified metal feature on a carrier near this sensor at the required transfer position. The non-flush installation, 12 mm nominal range and 9.72 mm assured range guide placement. The PNP normally-open signal reports the local carrier condition, while IP68/IP69K protection and cleaning-agent resistance support the specified washdown environment.

Problem Solved

A contactless carrier-position signal gives the sequence controller a reference before transfer, avoiding a mechanical feeler against the carrier at a station exposed to cleaning operations.

Washdown station Metal carrier PNP

2. Counting metal components at a guided feeder

A guided feeder can carry individual qualified metal components past the sensing face so each passage changes the normally-open output. An external counter reads these transitions. The 1,000 Hz switching frequency and 3–20% hysteresis guide target spacing and timing, while the listed target-material reduction factors must be considered when qualifying different metal components.

Problem Solved

A noncontact component-passage event supports quantity tracking at the feeder exit without a counting lever touching each part, with counting and feed decisions performed by the external controller.

Metal-part counting 1,000 Hz Material factors

3. Checking target engagement during machine setup

A setup screen can read the one-byte IO-Link process data while a metal actuator is brought toward the sensor. Bit 0 reports Sr reached and bit 1 reports Sa reached. These discrete states supplement the local visual adjustment aid, allowing the operator interface to distinguish the two documented target-engagement states during mechanical setup.

Problem Solved

Remote target-engagement feedback helps operators check actuator placement from the machine interface when the local indicator is difficult to see, without treating the sensor as a continuous distance-measuring device.

IO-Link V1.0 Sr/Sa states Commissioning