Technical Overview

The SICK IMF30-20NNSNC0S is an M30 non-flush inductive proximity sensor for hygienic and washdown zones. It provides a 20 mm nominal sensing range and 16.2 mm assured range, with a normally-open NPN output and 500 Hz switching. The stainless steel V4A housing uses DIN 1.4404/AISI 316L, while the sensing face is LCP plastic. Cleaning-agent resistance, IP68/IP69K protection and a −40 to +100 °C operating range support demanding machine environments. A visual adjustment indicator supports checking the target position during installation. An M12 four-pin connector with gold-plated contacts connects the DC three-wire device to a 10–30 V DC supply.

M30 non-flush inductive sensor with 15/16.2 mm nominal/assured ranges, NPN NO output, 500 Hz switching and IP68/IP69K protection.

Key Features

  • M30 metric housing; non-flush installation
  • 20 mm nominal range; 16.2 mm assured range
  • NPN normally-open output; DC three-wire; 500 Hz switching
  • V4A stainless steel housing, DIN 1.4404/AISI 316L; LCP sensing face
  • Resistant to cleaning agents; specified for hygienic and washdown zones
  • IP68 per EN 60529; IP69K per ISO 20653:2013-03
  • −40 to +100 °C ambient operation
  • 10–30 V DC; continuous output current ≤200 mA
  • M12 four-pin male connector with gold-plated contacts
  • Visual adjustment indicator; two V4A stainless steel mounting nuts supplied

Monitor metal targets in washdown machinery with a stainless steel inductive sensor, cleaning-agent resistance and a visual adjustment indicator.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical, standard design
Housing diameter30 mm
Housing threadM30
Sensing range Sn20 mm nominal
Assured sensing range Sa16.2 mm
InstallationNon-flush
Switching frequency500 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC three-wire
ConnectionM12 four-pin male connector; gold-plated contacts
Pin assignment1/BN: L+; 4/BK: NO; 3/BU: M; 2: not connected
Special featuresCleaning-agent resistance, visual adjustment indicator and temperature resistance
Specified application environmentHygienic and washdown zones; difficult application conditions
Power supply10–30 V DC
Residual ripple≤10%
Voltage drop≤2 V at maximum output current Ia
Hysteresis3–20%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
EMCAccording to EN 60947-5-2
Continuous output current≤200 mA
No-load current≤10 mA
Circuit protectionShort-circuit and power-up pulse protection
Shock and vibration data100 g / 2 ms / 500 cycles; 150 g / 1 million cycles; 10–55 Hz / 1 mm; 55–500 Hz / 60 g
Operating temperature−40 to +100 °C
Housing materialStainless steel V4A, DIN 1.4404 / AISI 316L
Sensing face materialLCP plastic
Protection classIII
UL fileE181493
MTTFD1,971 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsApproximate reference values, may vary: V2A/304=0.78; aluminum=0.44; copper=0.36; brass=0.46
Mounting clearancesA=20 mm; B=62 mm; C=30 mm; D=60 mm; E=20 mm; F=160 mm; follow manufacturer installation diagram
IP ratingIP68 per EN 60529; IP69K per ISO 20653:2013-03
Items suppliedTwo V4A stainless steel mounting nuts
Visual adjustment indicatorInstallation aid indicating the target zone between Sr and Sa; Sa =0.81 × Sn

Industrial Applications

1. Confirming a metal carrier at a washdown station

A packaging station can present a qualified metal feature on a carrier near this sensor at the required transfer position. The non-flush installation, 20 mm nominal range and 16.2 mm assured range guide placement. The NPN normally-open signal reports the local carrier condition, while IP68/IP69K protection and cleaning-agent resistance support the specified washdown environment.

Problem Solved

A contactless carrier-position signal gives the sequence controller a reference before transfer, avoiding a mechanical feeler against the carrier at a station exposed to cleaning operations.

Washdown station Metal carrier NPN

2. Counting metal components at a guided feeder

A guided feeder can carry individual qualified metal components past the sensing face so each passage changes the normally-open output. An external counter reads these transitions. The 500 Hz switching frequency and 3–20% hysteresis guide target spacing and timing, while the listed target-material reduction factors must be considered when qualifying different metal components.

Problem Solved

A noncontact component-passage event supports quantity tracking at the feeder exit without a counting lever touching each part, with counting and feed decisions performed by the external controller.

Metal-part counting 500 Hz Material factors

3. Aligning a metal actuator during fixture setup

A fixture setup can move an intended metal actuator toward the sensing face while the installer observes the visual adjustment indicator. The manufacturer installation-aid diagram distinguishes the target region between Sr and Sa, with Sa equal to 0.81 times the nominal range. Final mounting also follows the non-flush-installation clearances and target-material reduction factors.

Problem Solved

The local adjustment indication helps the installer establish a repeat actuator position in the specified detection zone, reducing reliance on repeated machine cycles simply to observe an output transition.

Visual setup aid Actuator alignment Non-flush mounting