SICK 7902120 IM12-04NAS-ZU0 AC NO Inductive Sensor

USD 113.62

M12 non-flush inductive sensor with 4 mm nominal range, AC two-wire NO, 20–250 V AC supply, 25 Hz switching and 2 m cable in an IP67 housing.

SKU SICK-7902120 Category
SICK IM AC

SICK IM12-04NAS-ZU0 AC Inductive Sensor

BrandSICK
Model IdentifierIM12-04NAS-ZU0
Official Part Number7902120

Technical Overview

The SICK IM12-04NAS-ZU0 is an M12 non-flush inductive proximity sensor with a normally-open AC two-wire switching function. Its nominal sensing range is 4 mm and its assured range is 3.24 mm, subject to target-material reduction factors. The sensor operates from 20–250 V AC with a 25 Hz switching frequency and availability within 10 ms. A 2 m PUR/PVC cable connects it to the compatible load circuit. The nickel-plated brass housing and PBT sensing face provide IP67 protection. Integration requires at least 8 mA load current, temperature-dependent continuous-current limits and an external fast-acting fuse of no more than 2 A.

M12 non-flush inductive sensor with 4/3.24 mm nominal/assured ranges, AC two-wire NO, 20–250 V AC supply and 2 m cable.

Key Features

  • M12 ×1 threaded cylindrical housing; non-flush installation
  • 4 mm nominal range; 3.24 mm assured range
  • AC two-wire normally-open (NO) switching
  • 20–250 V AC supply; 25 Hz switching
  • Availability ≤10 ms; voltage drop ≤8.5 V at maximum load current
  • 2 m PUR/PVC cable with two 0.5 mm² conductors
  • Minimum load current ≥8 mA; ≤250 mA at +50 °C or ≤200 mA at +80 °C
  • External fast-acting fuse ≤2 A specified for short-circuit protection
  • Nickel-plated brass housing; PBT sensing face; IP67
  • −25 to +80 °C operating range; two nickel-plated brass mounting nuts supplied

Detect qualified metal targets over a 4 mm nominal range with an AC two-wire normally-open switching condition.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical, standard design
Housing threadM12 ×1
Body diameter12 mm
Sensing range Sn4 mm nominal
Assured sensing range Sa3.24 mm
InstallationNon-flush
Switching frequency25 Hz
Output configurationAC two-wire, normally-open (NO)
Electrical wiringAC two-wire
Connection2 m two-wire cable
Connection diagramCD-121 referenced in exact sheet; brown BN and blue BU conductors
Power supply20–250 V AC
Voltage drop≤8.5 V at maximum load current
Time delay before availability≤10 ms
Hysteresis1–15%
Temperature drift±10% of Sr
EMCEN 55011 class B; EN 60947-5-2
Continuous current limits≤250 mA at +50 °C; ≤200 mA at +80 °C
Off-state current≤3 mA at 250 V AC; ≤1.5 mA at 120 V AC
Minimum load current≥8 mA
Short-time withstand current0.9 A for 20 ms at 0.5 Hz
Cable materialPUR/PVC
Conductor cross-section0.5 mm²
Short-circuit protectionExternal miniature fast-acting fuse ≤2 A specified by manufacturer
Power-up pulse protectionProvided
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
Operating temperature−25 to +80 °C
Housing materialNickel-plated brass
Sensing face materialPBT plastic
Housing length71 mm
Thread length46 mm
Maximum tightening torque≤7 Nm
Protection classI
IP ratingIP67 per EN 60529
MTTFD1,491 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsApproximate reference values, may vary: V2A/304=0.8; aluminum=0.45; copper=0.4
Mounting clearancesA=12 mm; B=24 mm; C=12 mm; D=12 mm; E=8 mm; F=32 mm; follow manufacturer installation diagram
Items suppliedTwo nickel-plated brass mounting nuts
Nut width across flats17 mm
IndicatorDisplay LED
Reproducibility≤10% of Sr with supply voltage and ambient temperature constant

Industrial Applications

1. Confirming a metal carrier at a transfer stop

A transfer station can present a qualified metal carrier feature to the sensing face at its defined stopping position. The 4 mm nominal range and 3.24 mm assured range guide placement for non-flush mounting. A compatible AC load circuit evaluates the NO switching condition and supplies the external sequence controller with a local position reference.

Problem Solved

A noncontact carrier-position condition gives the external transfer sequence a local arrival reference without placing a mechanical sensing lever in repeated contact with the monitored metal carrier.

Carrier position 4 mm range AC NO

2. Checking a metal component in an assembly fixture

An assembly fixture can bring a qualified metal component into the detection zone at a defined inspection point. The AC two-wire switching condition reports local presence to compatible external control equipment. Material reduction factors guide qualification of stainless steel, aluminum and copper parts, and the control circuit interprets the selected output condition before advancing the assembly sequence.

Problem Solved

A metal-presence condition helps the external control sequence identify an empty monitored fixture position without relying on a visible surface mark or a contact probe against the component.

Fixture presence Metal targets Material factors

3. Counting spaced metal carriers on a conveyor

Separated metal carrier features can pass through the detection zone and deliver switching transitions to compatible external counting equipment through the AC load circuit. Target spacing and event rate must remain within the 25 Hz switching frequency. Circuit design must also meet the minimum 8 mA load requirement and the documented off-state-current limits.

Problem Solved

A qualified carrier-passage event supports throughput tracking without a contact counting arm, while external equipment performs the count and coordinates the material feed at the monitored conveyor location.

Carrier counting 25 Hz External counter