SICK 6021127 IM18-08N-N-ZW0 NAMUR NC Inductive Sensor

USD 80.34

M18 non-flush NAMUR NC inductive sensor with 8 mm nominal range, 300 Hz switching, 2 m PVC cable, IP67 protection and ATEX certificate PTB 03 ATEX 2037.

SKU SICK-6021127 Category
SICK IMN

SICK IM18-08N-N-ZW0 NAMUR Inductive Sensor

BrandSICK
Model IdentifierIM18-08N-N-ZW0
Official Part Number6021127

Technical Overview

The SICK IM18-08N-N-ZW0 is an M18 non-flush NAMUR inductive proximity sensor with a normally-closed output characteristic. It detects qualified metal targets at a nominal range of 8 mm and an assured range of 6.48 mm, subject to material reduction factors. Its two-wire current signal falls to no more than 1 mA when activated and is at least 2.2 mA when not activated. Switching frequency is 300 Hz. The nickel-plated brass housing, plastic sensing face and 2 m PVC cable provide IP67 integration. The ATEX-listed device connects only to a separately certified intrinsically safe circuit for hazardous-area use, within the documented entity limits. The 7.5–25 V DC supply range applies outside hazardous areas.

M18 non-flush NAMUR NC sensor with 8/6.48 mm nominal/assured ranges, 300 Hz switching and 2 m PVC cable; hazardous-area use requires a separately certified intrinsically safe circuit.

Key Features

  • M18 metric thread; non-flush installation
  • 8 mm nominal range; 6.48 mm assured range
  • NAMUR normally-closed current-switching characteristic
  • Activated current ≤1 mA; not-activated current ≥2.2 mA
  • 300 Hz switching frequency
  • 2 m PVC two-wire cable; 0.5 mm² conductors
  • ATEX certificate PTB 03 ATEX 2037; device categories1G and2G
  • Hazardous-area connection only to a separately certified intrinsically safe circuit
  • 7.5–25 V DC outside hazardous areas; 8.2 V nominal at1 kΩ
  • Nickel-plated brass housing; plastic face; IP67; −20 to +70 °C

Detect metal targets with a 8 mm nominal range and a two-wire NAMUR current signal for compatible external evaluating equipment.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formMetric cylindrical
Housing threadM18 ×1
Body diameter18 mm
Sensing range Sn8 mm nominal
Assured sensing range Sa6.48 mm
InstallationNon-flush
Switching outputNAMUR
Output functionNormally-closed (NC)
Switching frequency300 Hz
Connection2 m two-wire cable
Conductor functionsBrown BN=L+; blue BU=M; CD-012
Power supply outside hazardous areas7.5–25 V DC
Nominal voltage8.2 V DC at1 kΩ
Activated current≤1 mA
Not-activated current≥2.2 mA
Hysteresis1–15%
Temperature drift±10% of Sr
EMCEN60947-5-6
Cable materialPVC
Conductor cross-section0.5 mm²
Cable diameter5.4 mm
Cable resistance50 Ω
Shock resistance30 g,11 ms
Vibration resistance10–55 Hz,1 mm
Operating temperature−20 to +70 °C
Housing materialNickel-plated brass
Sensing face materialPlastic
Housing length33 mm
Thread length24 mm
Maximum tightening torque35 Nm
IP ratingIP67 per EN60529
Type approval certificatePTB 03 ATEX 2037
Ex area categories1G,2G
Hazardous-area circuit conditionFor connection only to a separately certified intrinsically safe circuit; match all certified circuit/entity limits
Entity input voltage Ui max15 V; separately certified intrinsically safe circuit only
Entity input power Pi max120 mW; separately certified intrinsically safe circuit only
Entity input current Ii max50 mA; separately certified intrinsically safe circuit only
Internal capacitance Ci max155 nF; separately certified intrinsically safe circuit only
Internal inductance Li max50 µH; separately certified intrinsically safe circuit only
Device markingII 1G Ex ia IIC T6 Ga, Ta−20 to+70 °C; II 2G Ex ia IIC T6 Gb, Ta−20 to+70 °C
MTTFD7,219 years
Diagnostic coverage DCavg0%
Mission time20 years
Target-material reduction factorsApproximate reference values that may vary: V2A/304=0.7; aluminum=0.4; copper=0.3; brass=0.5
Mounting clearancesA=18 mm; B=36 mm; C=18 mm; D=24 mm; E=16 mm; F=64 mm; follow exact manufacturer installation diagram
Items suppliedTwo nickel-plated brass mounting nuts
Nut width across flats24 mm
Physical Weight (kg)0.164

Industrial Applications

1. Monitoring a valve actuator metal position flag

A valve actuator can move a qualified metal flag into the sensor range at a defined travel position. The 8 mm nominal range and non-flush mounting guide placement. Compatible NAMUR evaluating equipment interprets the activated and not-activated current states. Hazardous-area installations use a separately certified intrinsically safe circuit that matches the documented device entity limits.

Problem Solved

A local noncontact metal-flag condition gives external valve-control logic a travel-position reference without placing a mechanical sensing lever against the monitored moving actuator component during repeated operation.

Valve position NAMUR NC Current-state evaluation

2. Checking a metal component in a process fixture

A process fixture can present a qualified metal component to the sensing face at a defined assembly or handling position. The NAMUR current characteristic supplies a local presence condition to compatible external evaluating equipment. Target-material reduction factors guide qualification for different metals, and hazardous-area use requires a separately certified intrinsically safe circuit within the listed entity limits.

Problem Solved

A metal-presence condition helps external sequence control identify an empty monitored fixture position without relying on a visible surface mark or a contact probe against the component.

Fixture presence Metal targets NAMUR evaluation

3. Counting separated metal carrier features

A material-handling mechanism can move separated qualified metal features through the detection zone and send the NAMUR current transitions to compatible external counting equipment. Feature spacing and passage rate remain within the 300 Hz switching frequency. The external evaluating circuit distinguishes the two current states; hazardous-area use also requires a separately certified intrinsically safe circuit.

Problem Solved

A qualified metal-passage event supports throughput tracking without a mechanical counting arm, while external equipment performs the count and coordinates the feed at the monitored process location.

Metal-feature counting 300 Hz External counter
Select your currency