SICK 1041323 MZ2Q-FTZPS-KQ0 Two-Point PNP Cylinder Sensor

USD 114.92

T-slot cylinder sensor with two taught PNP NO switching points, a 0–50 mm detection zone, 12–30 V DC supply, 0.3 m M12 four-pin cable and IP67.

SKU SICK-1041323 Category
SICK MZ2Q-T

SICK MZ2Q-FTZPS-KQ0 Two-Point PNP Cylinder Sensor

BrandSICK
Model IdentifierMZ2Q-FTZPS-KQ0
Official Part Number1041323

Technical Overview

The SICK MZ2Q-FTZPS-KQ0 is a magnetic cylinder sensor with two PNP normally-open switching outputs and a 0–50 mm detection zone. Two piston positions are stored through the teach-in control panel, allowing external machine control to distinguish the taught positions using one T-slot sensor. The 40 mm plastic housing includes separate indication for the switching points and operates from 12–30 V DC. Typical no-load current is 25 mA, voltage drop is limited to 2.2 V and the listed continuous-current limit is 100 mA. An axial 0.3 m PUR cable terminates in an M12 four-pin plug. IP67 protection, reverse-polarity protection, short-circuit protection and power-up pulse protection support integration.

Two-point magnetic T-slot cylinder sensor with two taught PNP NO outputs, a 0–50 mm detection zone and a 0.3 m PUR cable with M12 four-pin plug.

Key Features

  • Two PNP normally-open switching outputs
  • Detection zone0–50 mm; two taught switching points
  • Direct T-slot mounting; 40 mm housing length
  • Teach-in with the supplied tool or plastic pin
  • 12–30 V DC; typical no-load current25 mA
  • Voltage drop≤2.2 V; listed continuous current≤100 mA
  • Typical hysteresis1 mT; reproducibility≤0.1 mT at constant supply and temperature
  • Axial0.3 m PUR cable with M12 four-pin plug
  • Plastic housing; IP67; −20 to+75 °C operation
  • Separate point indication; reverse-polarity, short-circuit and power-up pulse protection

Monitor two taught piston positions within a 50 mm detection zone using one T-slot sensor and separate PNP switching outputs.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic cylinder-piston detection
Cylinder typeT-slot; direct mounting
Cylinder types with adapterProfile, tie rod, round body, dovetail groove; SMC rail CDQ2/ECDQ2; suitable adapters required
Detection zone0–50 mm
Housing length40 mm
Switching output2×PNP
Output function2×NO; normally open
Electrical wiringDC four-wire
Power supply12–30 V DC
No-load currentTypical25 mA
Voltage drop≤2.2 V
Continuous current≤100 mA; listed manufacturer limit
Protection classIII
HysteresisTypical1 mT
Reproducibility≤0.1 mT with supply voltage and ambient temperature constant
Reverse-polarity protectionProvided
Short-circuit protectionProvided
Power-up pulse protectionProvided
Status indicatorLED indication for switching points1 and2
Teach-inControl panel; two switching points
Teach procedureUse supplied teach tool or plastic pin; hold teach3 s at point1, release, then briefly press at point2; verify both points
Operating temperature−20 to+75 °C
Shock resistance30 g,11 ms
Vibration resistance10–55 Hz,1 mm
EMCEN60947-5-2
Connection0.3 m PUR cable with M12 four-pin plug
Cable diameter2.6 mm
Bending radiusFixed installation>5×cable diameter; flexible use>10×cable diameter
Cable outletAxial
Housing materialPlastic
Cable materialPUR
Pin assignment1/BN=L+;3/BU=M;2/WH=Q1;4/BK=Q2;CD-032
IP ratingIP67 per EN60529
Mounting screwSW1.5
UL fileNRKH.E181493 and NRKH7.E181493
MTTFD799 years
Diagnostic coverage DCavg0%
Mission time20 years

Industrial Applications

1. Sequencing a short-stroke transfer at two positions

A short-stroke transfer cylinder can use two taught piston positions within the 0–50 mm detection zone. The two PNP normally-open outputs provide separate arrival conditions to external sequence control. After both positions are taught with the supplied tool, the controller checks the corresponding switching input before commanding the next transfer movement.

Problem Solved

Two local arrival conditions let the sequence controller distinguish the taught transfer positions using one sensor, reducing the need to allocate two separate sensing housings along the cylinder slot.

Two positions PNP outputs T-slot

2. Timing movement between taught positions externally

A machine controller can timestamp the switching events from Q1 and Q2 as the cylinder piston moves between the taught positions. The sensor supplies separate magnetic position events, while the controller calculates the elapsed interval and compares it with the configured process threshold. The documented reproducibility applies with supply voltage and ambient temperature constant.

Problem Solved

An event-to-event interval helps external control identify motion that takes longer than its configured process limit, using detected piston positions rather than assuming completion after a fixed delay.

External timing Q1/Q2 Repeatability

3. Recording completed cylinder cycles externally

External machine logic can qualify the expected sequence of Q1 and Q2 switching events and record one completed cycle when the piston returns to the taught reference position. The sensor provides two local magnetic switching conditions within its detection zone. Counting, direction interpretation and rejection of repeated events are performed by the connected controller.

Problem Solved

A qualified two-position sequence supports production or maintenance cycle records and helps the external counter distinguish a completed return cycle from repeated events at a single position.

Cycle records Two-point sequence External counter
Select your currency