SICK 6054711 UC30-214162 Dual PNP Ultrasonic Sensor

USD 518.18

UC30-214162 provides 350–3,400 mm ultrasonic operation, two PNP outputs, teachable switching modes, temperature compensation and an M12 5-pin connector.

SKU SICK-6054711 Category
Ultrasonic Distance Sensors - SICK UC30

SICK UC30-214162 Dual PNP Ultrasonic Distance Sensor

BrandSICK
Model IdentifierUC30-214162
Official Part Number6054711

Technical Overview

The SICK UC30-214162 is an ultrasonic distance sensor with a 350–3,400 mm operating range and two PNP switching outputs. Its 5,000 mm limiting range is distinct from the operating range, and detection depends on target reflection, size and alignment. Teachable switching-point, switching-window and background modes adapt the output condition to the installation. Temperature compensation, adjustable measurement filters and sensitivity support setup, while synchronization or multiplexing coordinates up to 50 sensors. The sensor specifies 180 ms response, 4 Hz switching and 43 ms output time. A rectangular PBT/PET housing, straight sending axis, M12 five-pin male connector and IP65/IP67 protection support installation on machinery.

350–3,400 mm ultrasonic distance sensor with two PNP outputs, teachable switching modes, temperature compensation, synchronization and M12 5-pin connection.

Key Features

  • 350–3,400 mm operating range;5,000 mm limiting range
  • Two PNP digital outputs;maximum output current≤200 mA
  • Switching-point,window and background modes with teach-in
  • 180 ms response;4 Hz switching;43 ms output time
  • Temperature compensation;±1% accuracy relative to current measurement
  • Adjustable measurement filters,sensitivity and sound beam
  • Synchronization or multiplexing for up to50 sensors
  • 9–30 V DC;≤1.2 W without load;initialization<380 ms
  • M12 five-pin male connector;two LED indicators
  • IP65/IP67 PBT/PET housing;−25 to+70 °C operation

Set distance-based switching conditions for external control using ultrasonic echoes, with target-dependent detection and coordinated operation for multiple sensors.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic distance sensing
Operating range350–3,400 mm
Limiting range5,000 mm;distinct from operating range
Detection areaTarget dependent;affected by reflection properties,size and alignment;manufacturer diagrams use aligned500 ×500 mm plate andØ27 mm pipe
Resolution≥0.18 mm
Repeatability±0.15% of current measured value;minimum value≥resolution
Measurement accuracy±1% of current measured value
Temperature compensationAvailable;can be switched off;without compensation0.17%/K
Response time180 ms
Switching frequency4 Hz
Output time43 ms
Ultrasonic frequencyTypical120 kHz;acoustic frequency
Switching modesSwitching point(DtO),switching window,background(ObSB)
Adjustment functionsTeach digital output,set output levels,invert output,set ON-delay,reset to factory defaults
Measurement filtersAdjustable measured-value filter/filter strength,foreground suppression,detection area,sensitivity and sound beam
SynchronizationUp to50 sensors
MultiplexingUp to50 sensors for operation without cross talk in multiplex mode
Digital outputs2 ×PNP;maximum output current≤200 mA
Multifunctional input1 ×MF
Hysteresis50 mm
Power supply9–30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A,Class2
Power consumption≤1.2 W without load
Initialization time<380 ms
Indicators2 ×LED
IP ratingIP65/IP67
Protection classIII
ConnectionM12 five-pin male connector
Pin assignment1BN=L+;3BU=M;2WH=Q1/invertedQ1;4BK=Q2/invertedQ2;5GY=synchronization/multiplex and Connect+ communication
Sending axisStraight
Housing materialPBT/PET plastic
Transducer materialsPolyurethane foam and glass epoxy resin
Operating temperature−25 to+70 °C
Storage temperature−40 to+85 °C
MTTFD101 years
DCavg0%
Physical Weight (kg)0.18

Industrial Applications

1. Setting a container fill-level threshold

A level station can mount the sensor above a container and teach switching conditions for a sufficiently reflecting material surface within350–3,400 mm. The controller receives the selected digital output when the taught distance condition changes. Actual surface alignment and echo behavior are checked, and the180 ms response is considered when matching the installation to the filling process.

Problem Solved

Distance-based level switching gives external control a repeatable process condition for filling or replenishment, reducing reliance on a fixed visual estimate of the material surface position.

Level threshold Teach-in Ultrasonic echo

2. Checking whether a load is in a distance window

A handling station can define a switching window for an adequately reflecting load face positioned inside the operating range. The sensor is aligned to obtain a reliable echo, and external control interprets its selected output as the configured window condition. Target size and angle are verified against the detection characteristics before using that signal in the machine sequence.

Problem Solved

A taught distance window distinguishes a load in the expected position from one outside the allowed zone, providing more positional information than a simple far-range presence threshold.

Load position Switching window Target alignment

3. Coordinating nearby ultrasonic inspection points

A machine can use several compatible ultrasonic sensors at neighboring inspection positions and configure synchronization or multiplexing according to the required echo separation. This model supports groups of up to50 sensors, with the multifunction connection providing the coordinated mode. Each target is validated within its operating range, and external control uses the individual switching results for the machine sequence.

Problem Solved

Coordinating acoustic measurements addresses interference between nearby inspection points, helping external control interpret each station result without treating echoes from another sensor as the intended target return.

Synchronization Multiplexing Multiple stations