| Functional principle | Time-of-flight laser distance measurement |
| Target | Natural objects |
| Measuring range | 200–30,000 mm on90% remission at Slow speed;200–17,000 mm at18% remission;200–10,000 mm at6% remission;see manufacturer characteristic curves |
| Resolution | 100 µm |
| Repeatability | ≥0.5 mm;1σ;6–90% remission;depends on distance and speed;see manufacturer characteristic curves |
| Measurement accuracy | ±7 mm;6–90% remission |
| Speed settings | Super Fast through Super Slow |
| Response time | 0.83/3.33/8.33/25/75 ms,depending on selected speed;lateral object entry |
| Switching frequency | 1,000/250/100/33/11 Hz,depending on selected speed;lateral object entry |
| Output time | 0.33/1.33/3.33/10/30 ms,depending on selected speed;continuous distance change |
| Light source | Visible red laser;658 nm |
| Laser class | 2;IEC60825-1:2014 and EN60825-1:2014 |
| Laser pulse figures | Maximum output250 mW;pulse duration3 ns;duty cycle1/250 |
| Laser handling | Do not intentionally look into the beam or point it at eyes |
| Typical light spot | 10 ×10 mm at10 m |
| Average laser service life | 100,000 h at25 °C |
| IO-Link | V1.1;COM3,230.4 kBaud;process data,parameterization,diagnosis,data storage |
| Digital outputs | 1–2 push-pull PNP/NPN;Q1 switching and Q2 configurable;maximum output current≤100 mA;total<200 mA;short-circuit protected;voltage drop<3 V |
| Q2 configuration | One shared output selectable as4–20 mA,0–10 V,digital,invertedQ1 or deactivated |
| Analog current option | 4–20 mA;load≤450 Ω;selected on Q2 |
| Analog voltage option | 0–10 V;load≥50,000 Ω;selected on Q2 |
| Analog-output resolution | 16 bit |
| Switching modes | Distance to object(DtO),switching window,object between sensor and background(ObSB) |
| Output adjustment | Teach-in,scaling and inversion of analog/digital output;Easy Teach |
| Shape comparison | Compares distance measured over time against a taught reference |
| Other functions | Hold measurement value;reset;switch off or lock display |
| Multifunctional input | Laser off,external teach or deactivated;input response≤60 ms |
| Hysteresis | 0–29,950 mm |
| Power supply | 10–30 V DC;IO-Link requires>18 V;analog requires>13 V;reverse-polarity protected |
| Supply network requirement | Short-circuit protected network,max8 A |
| Power consumption | ≤1.7 W without load at≥0 °C |
| Supply ripple | ≤5 Vpp;must remain within supply limits |
| Initialization time | ≤300 ms |
| Warm-up time | ≤15 min |
| Indicators and display | 3LEDs and LC display |
| Connection | M12 five-pin male connector |
| Pin assignment | 1BN=L+;3BU=M;4BK=Q1/C;2WH=QA/Q2/invertedQ1/deactivated;5GY=MF |
| Housing material | Zinc diecast |
| Window material | PMMA plastic |
| IP rating | IP65/IP67 |
| Protection class | III |
| Operating temperature | −40 to+65 °C at supply≤24 V |
| Optional cooled operation | −30 to+140 °C only with2cooling plates2055755 and water cooling;heat protection filter2085598 optional |
| Storage temperature | −40 to+75 °C |
| Relative humidity | ≤95%;non-condensing |
| Ambient light immunity | Typical40,000 lx |
| Vibration resistance | IEC60068-2-64:2008;20–500 Hz,10 g RMS,2h/axis |
| Shock resistance | IEC60068-2-27:2008;30 g/11 ms,3axes,±3single shocks/axis;10 g/6 ms,3axes,±500/axis;70 g/6 ms,Yaxis,±100,000 |
| EMC | EN61000-6-2 and EN61000-6-4;ClassA |
| MTTFD | 101 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.235 |
| Dimensions L x W x H (cm) | 5.86 x 3.62 x 7.28 |