Skip to content

Contact Us:
sales@inosaki.com

SICK 1058986 DL50-P2228 SSI Reflector Distance Sensor

SICK 1058986 DL50-P2228 SSI Reflector Distance Sensor

USD 2,055.30

Reflector distance sensor measures0.2–50 m on Diamond Grade tape,with SSI output,selectable averaging,PNP switching and an IP65 M12 eight-pin housing.

SKU: SICK-1058986 Category:
Laser Distance Sensors - SICK Dx50

SICK DL50-P2228 SSI Reflector Distance Sensor

BrandSICK
Model IdentifierDL50-P2228
Official Part Number1058986

Technical Overview

The SICK DL50-P2228 measures distance to Diamond Grade reflective tape over 0.2–50 m using a class 1 red time-of-flight laser. SSI carries distance data, with selectable SSI increments of 0.0625, 0.1, 0.125 or 1 mm. A PNP output supplies a taught switching condition; the multifunction terminal can become a second output or serve as laser-off or external-teach input. Fast, medium and slow averaging settings give specified responses of 10, 40 and 160 ms for lateral target entry, while output time is 2.5 ms for continuous distance change. The IP65 zinc-diecast sensor has an LC display, two LEDs, an M12 eight-pin connector and warm-up up to fifteen minutes.

0.2–50 m reflector distance sensor for Diamond Grade tape,with SSI distance output,selectable averaging and one or two configuration-dependent PNP outputs.

Key Features

  • 200–50,000 mm measuring range on Diamond Grade reflective tape
  • 658 nm class1 red laser;typical15 ×15 mm spot at10 m
  • 100 µm sensor resolution;SSI increments0.0625/0.1/0.125/1 mm
  • Typical repeatability≥0.25 mm,1σ,depending on averaging
  • 10/40/160 ms lateral-entry response;2.5 ms output time for continuous distance change
  • Native SSI distance output
  • One PNP output;shared Q2/MF terminal adds output or input functions
  • Taught distance-to-object switching;adjustable1–1,000 mm hysteresis
  • LC display,two LEDs and M12 eight-pin male connector
  • 10–30 V DC;IP65 zinc-diecast housing;warm-up≤15 min

Measure the position of a reflector-equipped moving assembly and pass distance values or taught switching conditions to external control.

Technical Specification Matrix

ParameterValue
Functional principleTime-of-flight laser distance measurement to a reflector
Measuring range200–50,000 mm on Diamond Grade reflective tape
TargetReflector;Diamond Grade tape required for stated range
Resolution100 µm
RepeatabilityTypical≥0.25 mm;1σ;depends on fast/medium/slow averaging
Measurement accuracy±3 mm;within200–4,000 mm,≤±5 mm
AveragingFast,medium,slow
Response time10/40/160 ms,depending on averaging;lateral target entry
Output time2.5 ms;continuous change of distance
Light sourceVisible red laser;658 nm
Laser class1;IEC60825-1:2014 and EN60825-1:2014
Laser pulse figuresMaximum output80 mW;pulse duration2.5 ns;duty cycle1/240
Laser handlingDo not intentionally look into the beam or point it at eyes
Typical light spot15 ×15 mm at10 m
Average laser service life100,000 h at25 °C
Communication interfaceSSI
SSI output incrementSelectable0.0625/0.1/0.125/1 mm;distinct from100 µm sensor resolution
Digital outputs1–2 PNP,depending on Q2/MF configuration;maximum output current≤100 mA;short-circuit protected
Q2/MF configurationShared terminal selectable as second digital output,laser off,external teach or deactivated
Switching modeDistance to object(DtO)
Output adjustmentTeach-in,scaling,inversion and adjustable hysteresis
Hysteresis1–1,000 mm
MF input response≤60 ms,when configured as input
Other functionsCrosstalk protection,switch-off display,reset,lock user interface
Power supply10–30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A
Power consumption≤2.1 W without load
Supply ripple≤5 Vpp;must remain within supply limits
Initialization time≤250 ms
Warm-up time≤15 min
Indicators and displayLC display and2LEDs
ConnectionM12 eight-pin male connector
Pin assignment2BN=L+;7BU=M;1WH=Q1;5GY=Data−;6PK=Data+;3GN=CLK−;4YE=CLK+;8RD=Q2/MF
Housing materialZinc diecast
Window materialPMMA plastic
IP ratingIP65
Protection classIII
Operating temperature−30 to+65 °C
Storage temperature−40 to+75 °C
Relative humidity≤95%;non-condensing
Ambient light immunityTypical40,000 lx
Vibration resistanceEN60068-2-6 and EN60068-2-64
Shock resistanceEN60068-2-27
MTTFD101 years
DCavg0%
Physical Weight (kg)0.2
Dimensions L x W x H (cm)5.77 x 3.61 x 7.27

Industrial Applications

1. Following a rail carriage position

A rail carriage can carry Diamond Grade reflective tape facing the stationary sensor along the measuring path. Within200–50,000 mm,the sensor supplies distance values through SSI to an external positioning controller. Reflector alignment,averaging and the15-minute warm-up limit are considered during commissioning;the controller provides the motion-control strategy and validates achieved positioning behavior.

Problem Solved

A continuous reflector-distance value gives external positioning control a reference over the carriage travel,supporting numerical correction and travel monitoring between discrete end-position switches.

Carriage position SSI Reflector

2. Setting a lift-platform height condition

A lift platform can carry the specified reflective tape so its position remains visible along the measurement axis. A taught PNP switching condition identifies the selected height region for external lift control. If a second output is needed,the shared Q2/MF terminal is configured accordingly,with its input functions then unavailable. Alignment and the required averaging response are validated over the actual platform travel.

Problem Solved

A taught reflector-distance condition supplies external lift control with a repeatable height reference,helping coordinate a transfer step at the selected position without requiring contact with the moving platform.

Lift height PNP condition Shared terminal

3. Monitoring spacing between moving assemblies

One machine assembly can carry the sensor while another carries Diamond Grade reflective tape aligned with the optical path. SSI values report their changing separation within the stated range to external supervisory control. The installation is tested for alignment over the permitted movement,and averaging is selected for the required response. External control evaluates spacing limits and implements any machine response.

Problem Solved

A changing separation value lets external supervisory control follow the relative gap between assemblies,providing numerical information for coordination beyond a single fixed proximity threshold.

Relative gap SSI distance External coordination