SICK 1047398 DT50-N2113 NPN 4–20 mA Distance Sensor

USD 1,995.24

DT50-N2113 measures0.2–20 m on90% remission with a NPN output,4–20 mA analog signal,three averaging settings,16-bit output resolution and IP65 protection.

SKU SICK-1047398 Category
Laser Distance Sensors - SICK Dx50

SICK DT50-N2113 NPN Analog Laser Distance Sensor

BrandSICK
Model IdentifierDT50-N2113
Official Part Number1047398

Technical Overview

The SICK DT50-N2113 measures distance to natural objects using a class 2 red time-of-flight laser. Range is 200–20,000 mm at 90% remission, 200–8,500 mm at 18% remission and 200–5,000 mm at 6% remission. One NPN switching output and one 4–20 mA analog output support external machine control. The analog signal has 16-bit output resolution,with teach-in,scaling and inversion. Fast,medium and slow averaging give specified15/30/80 ms lateral-entry response;output time is≥2 ms for continuous distance change. A multifunction input supports laser-off or external teach. The IP65 zinc-diecast sensor has an LC display,two LEDs and an M12 five-pin connector,with warm-up up to fifteen minutes.

Target-dependent200–20,000 mm distance sensor with one NPN output,one4–20 mA output,16-bit analog-output resolution and three averaging settings.

Key Features

  • 200–20,000 mm at90% remission;200–8,500 mm at18%;200–5,000 mm at6%
  • 658 nm class2 red laser;typical15 ×15 mm spot at10 m
  • One NPN digital output;maximum current≤100 mA
  • One 4–20 mA analog output;load≤300 Ω;16-bit output resolution
  • Teach-in,scaling and inversion of analog/digital outputs
  • Fast/medium/slow averaging;15/30/80 ms lateral-entry response
  • Output time≥2 ms for continuous distance change
  • Distance-to-object switching;10–1,000 mm hysteresis;laser-off/teach input
  • LC display,two LEDs and M12 five-pin male connector
  • IP65 zinc-diecast housing;−30 to+65 °C operation;warm-up≤15 min

Send a distance-related analog signal and a taught switching condition to external machine control,with target remission and electrical loads checked for the installation.

Technical Specification Matrix

ParameterValue
Functional principleTime-of-flight laser distance evaluation
TargetNatural objects
Measuring range200–20,000 mm at90% remission;200–8,500 mm at18%;200–5,000 mm at6%
Repeatability≥1 mm;1σ;6–90% remission;depends on fast/medium/slow averaging
AveragingFast,medium or slow
Response time15/30/80 ms,depending on fast/medium/slow averaging;lateral object entry
Light sourceVisible red laser;658 nm
Laser class2;IEC60825-1:2014 and EN60825-1:2014
Laser pulse figuresMaximum output180 mW;pulse5 ns;duty cycle1/200
Laser handlingDo not intentionally look into the beam or point it at eyes
Typical light spot15 ×15 mm at10 m
Average laser service life100,000 h at25 °C
Digital outputs1 ×NPN;maximum output current≤100 mA;short-circuit protected
Switching modesDistance to object(DtO)
Output adjustmentTeach-in,scaling and inversion of digital and analog outputs
Hysteresis10–1,000 mm
Multifunction inputLaser off,external teach or deactivated;input response≤15 ms
Other functionsSwitch-off display,reset,lock user interface
Power supply10–30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A
Power consumption≤2.1 W without load
Supply ripple≤5 Vpp;must remain within supply limits
Initialization time≤250 ms
Warm-up time≤15 min
Indicators and displayLC display and2LEDs
ConnectionM12 five-pin male connector
Pin assignment1BN=L+;3BU=M;4BK=Q digital;2WH=QA analog;5GY=MF
Housing materialZinc diecast
Window materialPMMA plastic
IP ratingIP65
Protection classIII
Operating temperature−30 to+65 °C
Storage temperature−40 to+75 °C
Relative humidity≤95%;non-condensing
Ambient light immunityTypical40,000 lx
Vibration resistanceEN60068-2-6 and EN60068-2-64
Shock resistanceEN60068-2-27
MTTFD101 years
DCavg0%
Physical Weight (kg)0.2
Dimensions L x W x H (cm)5.77 x 3.61 x 7.27
Resolution1,000 µm
Measurement accuracy±7 mm at90% remission
Analog output1 ×4–20 mA;load≤300 Ω
Analog-output resolution16 bit
Output time≥2 ms;continuous change of distance

Industrial Applications

1. Following a container surface level

A container can present a sufficiently reflecting material surface inside the remission-dependent range and use the 4–20 mA output as a distance reference for external level control. The controller derives level from the installed geometry and taught analog span. Actual surface return,averaging,warm-up and theload≤300 Ω receiving input are checked before selecting process thresholds.

Problem Solved

An analog surface-distance value lets external process control follow changing fill level across a taught span,supplying information for replenishment or filling decisions between fixed switching events.

Level trend Analog distance External geometry

2. Estimating roll size from its outer surface

A roll station can aim the sensor at the outer material surface and send the selected 4–20 mA signal to external evaluation. With the roll axis and sensor reference fixed,the controller derives a roll-size estimate from measured distance. The actual surface remission determines usable range,and averaging is selected after checking the rotating material return and required response.

Problem Solved

A distance-derived roll-size estimate gives external unwind or rewind control a changing material reference,helping it follow consumption or build-up beyond a single fixed end-of-roll threshold.

Roll surface External calculation Averaging

3. Combining position feedback with a switching condition

A moving machine assembly can present a natural target within the appropriate remission-dependent range. The analog output passes distance information to an external positioning controller,while the single NPN output reports a taught distance condition for sequence coordination. The controller implements correction;the actual target,receiving load,≥2 ms output-time bound and selected averaging are validated for the intended movement.

Problem Solved

Providing analog distance information alongside a taught switching event lets external control follow position continuously and coordinate a selected sequence condition from the same measured target reference.

Position feedback Switching event External control
Select your currency