SICK 6034670 UC4-13345 NPN Ultrasonic Sensor

USD 351.78

UC4-13345 offers 13–150 mm ultrasonic operation,one NPN output,teach-in from21 mm,24 ms response and an IP65/IP67 ABS housing with M8 connection.

SKU SICK-6034670 Category
Ultrasonic Distance Sensors - SICK UC4

SICK UC4-13345 NPN Ultrasonic Sensor

BrandSICK
Model IdentifierUC4-13345
Official Part Number6034670

Technical Overview

The SICK UC4-13345 detects natural objects using ultrasonic echoes over a 13–150 mm operating range,with a separate 250 mm limiting range. One NPN output reports a taught switching condition;teach-in starts at21 mm. Distance-to-object,window and background modes,output inversion and a deactivatable local teach button adapt setup. The specified response is24 ms,switching frequency30 Hz and output time8 ms. Internal temperature compensation reaches its optimum after approximately one minute. The straight-sensing ABS unit has two LEDs and an M8 three-pin male connector,with IP65/IP67 protection. For operation above50 °C,the rear surface must sit flat against a mounting bracket.

13–150 mm ultrasonic sensor with one NPN output,teach-in from21 mm,24 ms response and M8 three-pin connection.

Key Features

  • 13–150 mm operating range;250 mm limiting range
  • Teach-in starts at21 mm
  • One NPN digital output;maximum current≤200 mA
  • Distance-to-object,window and background modes;invertible output
  • Local teach button;button deactivation and factory reset
  • 24 ms response;30 Hz switching;8 ms output time
  • Temperature compensation;optimum after approximately1 min
  • 15–30 V DC;≤0.75 W without load;startup<300 ms
  • M8 three-pin male connector;two LEDs;M3 mounting threads
  • IP65/IP67 ABS housing;above50 °C rear must contact bracket flat

Teach a short-range distance condition using ultrasonic echoes and pass the selected switching state to external machine control.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic object/distance detection
Operating range13–150 mm
Limiting range250 mm;distinct from operating range
Minimum teach distance21 mm
Detection areaDepends on reflection,size and alignment;reference diagrams use aligned100 ×100 mm plate andØ10 mm cylindrical bar
Resolution≥0.1 mm
Repeatability±0.15% of current measured value;minimum value≥resolution
Measurement accuracy±1% of current measured value
Temperature compensationAvailable;optimum after approximately1 min;factory calibration uses aluminum bracket and mounting screws
Response time24 ms
Switching frequency30 Hz
Output time8 ms
Ultrasonic frequencyTypical380 kHz;acoustic frequency
Digital output1 ×NPN;maximum current≤200 mA;short-circuit protected
Switching modesSwitching point(DtO),window,background(ObSB)
AdjustmentLocal teach-in,invert output,deactivate teach button,reset factory settings
Hysteresis2 mm
Power supply15–30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A
Power consumption≤0.75 W without load
Initialization time<300 ms
IndicatorsOrange:digital output;green:supply active
ConnectionM8 three-pin male connector
Pin assignment1BN=L+;3BU=M/0 V;4BK=Q/invertedQ
MountingM3 threaded mounting holes
Multiple-sensor separationParallel>250 mm;opposite>1,300 mm
Sending axisStraight
Housing materialABS plastic
Transducer materialsPolyurethane foam and glass epoxy resin
IP ratingIP65/IP67
Protection classIII
Operating temperature−25 to+70 °C;above50 °C rear surface must lie flat against a bracket
Storage temperature−40 to+85 °C
MTTFD101 years
DCavg0%
Physical Weight (kg)0.01

Industrial Applications

1. Checking a small part at a fixture reference

A fixture can present a sufficiently reflecting part surface inside the 13–150 mm operating range and teach its reference condition at a distance of at least21 mm. The single NPN output reports the selected condition to external inspection control. Actual target size,alignment and temperature behavior are checked before choosing the switching threshold and matching the24 ms response to the machine sequence.

Problem Solved

A taught surface-distance condition gives external inspection control a repeatable reference for a small part,helping it identify a displaced or missing surface before the next fixture operation.

Fixture reference Minimum teach distance Switching output

2. Checking a load face within a taught window

A compact handling station can teach two window boundaries for an expected load face,with teach points between21 and150 mm. External sequence control interprets the configured output state as the selected window condition. Actual surface reflection and alignment are validated,and the teach button can be deactivated after setup to retain the chosen operating configuration.

Problem Solved

A distance window supplies external handling control with an acceptance zone for the load face,helping distinguish a load placed too near or too far before a transfer action.

Position window Configuration retention Local teach

3. Detecting material in front of a reflecting background

A material station can teach a stable background at least21 mm from the sensor and inside the 13–150 mm operating range. Objects then pass between the sensor and that background,and external control uses the configured background-mode result. The actual material and background returns are checked,with the30 Hz switching specification considered for the intended presentation cycle.

Problem Solved

A taught background condition lets external sequence control distinguish material occupying the selected space from the background alone,providing a distance-based check when reflected optical contrast is limited.

Background reference Material presence Ultrasonic echo