SICK 6035500 VS/VE18-4N3140V NPN Through-beam Sensor Pair

USD 234.00

VS/VE18-4N3140V offers 0–18 m through-beam sensing, 880 nm infrared light, NPN output, sender test input, 316L housings and conditional IP69K protection.

SKU SICK-6035500 Category
SICK V18V

SICK VS/VE18-4N3140V Washdown Through-beam Sensor Pair

BrandSICK
Model IdentifierVS/VE18-4N3140V
Official Part Number6035500

Technical Overview

The SICK VS/VE18-4N3140V is a through-beam photoelectric sensor pair for hygienic and washdown zones. An opposing sender and receiver establish a direct optical path, with a 0–18 m sensing range and 0–20 m maximum range. The sender uses an 880 nm infrared LED with a typical 600 mm spot at 15 m; no sensitivity adjustment is provided. The receiver supplies an NPN output with control-wire selection of light/dark switching. A sender test input switches emission off when connected to 0 V. Response is ≤2 ms under resistive load, with 250 Hz operation at a 1:1 light/dark ratio. The 316L stainless-steel housings use M12 four-pin connectors. IP67/IP68 protection is specified; IP69K requires correctly mounted IP69K connectors.

Washdown through-beam sender/receiver pair with 0–18 m sensing range, 880 nm infrared LED, NPN receiver output, test input and 316L housings.

Key Features

  • Opposing sender/receiver through-beam arrangement
  • 0–18 m sensing range; 0–20 m maximum range
  • 880 nm infrared LED; typical Ø600 mm spot at 15 m
  • Axial optics; 2.5° dispersion and 8° reception angle
  • No sensitivity adjustment; control-wire light/dark selection
  • NPN receiver output, ≤100 mA; sender test input off at 0 V
  • ≤2 ms response with resistive load; 250 Hz at 1:1 light/dark ratio
  • 10–30 V DC; sender 35 mA / receiver 40 mA without load at 30 V
  • V4A stainless steel 1.4404/316L; M12 four-pin connections
  • IP67/IP68; IP69K with correctly mounted IP69K connectors

Detect interruptions of a direct sender-to-receiver beam across the process and use the sender test input to check the optical signal chain.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensing with opposing sender and receiver
Maximum sensing range0–20 m
Sensing range0–18 m
Light sourceInfrared LED
Wavelength880 nm
Light spot sizeTypically Ø600 mm at 15 m
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentNone
Special applicationHygienic and washdown zones
Digital outputNPN receiver output; maximum output current ≤100 mA
Switching modeLight/dark switching selectable via receiver L/D control wire
Signal voltage NPN HIGH/LOWApproximately supply voltage / <2.0 V
Response time≤2 ms signal transit time with resistive load
Switching frequency250 Hz at 1:1 light/dark ratio
Pin assignmentCD-219: sender 1 BN=L+, 2 WH=Test, 3 BU=M, 4 not connected; receiver 1 BN=L+, 2 WH=L/D, 3 BU=M, 4 BK=Q
Power supply10–30 V DC; limit values
Residual ripple±10%; remain within supply tolerances
Current consumptionSender 35 mA; receiver 40 mA; each without load at supply 30 V DC
Protection classIII
Housing designCylindrical
Housing materialV4A stainless steel, 1.4404 / 316L
Optics materialFlat plastic optics; manufacturer lists PPS (Grilamid)
Mounting threadM18 × 1
ConnectionMale M12 four-pin connector; gold-plated contact pins; PPS with FDA certificate
IP ratingIP67/IP68; IP69K with correctly mounted IP69K connector
Operating temperature−25 to +80 °C; +100 °C permitted for maximum 15 minutes
Storage temperature−40 to +80 °C
Physical Weight (kg)0.24
Test inputSender off when TE is connected to 0 V
Optical axisAxial
Angle of dispersion2.5°
Angle of reception8°
Attenuation along light beam≥20%

Industrial Applications

1. Counting separated opaque crates across a conveyor

A conveyor can place the sender and receiver on opposite sides of the crate path within the 0–18 m sensing range. Each separated opaque crate interrupts the direct infrared beam and changes the receiver state for external counting logic. Commissioning checks actual crate openings, product gaps and controller sampling against the specified 250 Hz switching frequency at a 1:1 light/dark ratio.

Problem Solved

A direct beam-interruption reference gives external counting logic a way to track separated crates, reducing dependence on crate color and surface reflection after openings and spacing have been checked.

Opaque crates Direct beam External counting

2. Confirming an opaque pallet at a transfer position

A transfer station can align the sender and receiver across the expected position of an opaque pallet or carrier. The receiver switching output supplies a local arrival state to external transfer logic. Commissioning verifies beam alignment, the actual blocking surface and pallet positioning variation, then tests the selected light/dark switching behavior against the required machine sequence before releasing upstream loads.

Problem Solved

A pallet-position reference helps external transfer control recognize whether the expected carrier has arrived, supporting coordinated release without requiring a reflector on the opposite side of the process.

Pallet presence Through-beam transfer External sequence

3. Checking the optical chain in a washed transport section

A transport section can use the opposed pair to monitor an opaque load crossing the infrared path. During a machine-controlled diagnostic sequence with the path otherwise clear, external control can connect the sender test input to 0 V and evaluate the receiver response. The installation uses correctly mounted IP69K connectors when that enclosure rating is required, then confirms normal reception after the test input is released.

Problem Solved

A commanded sender-off check gives external control a diagnostic reference for the optical signal chain, helping distinguish an expected test response from a receiver state that remains unchanged during the check.

Sender test Optical diagnostics Washdown transport
Select your currency