SICK 6035490 VTE18-4N4240V NPN Energetic Proximity Sensor

USD 133.90

VTE18-4N4240V offers 5–400 mm energetic proximity sensing, 880 nm infrared light, Touch-Teach-in, NPN output, a 316L housing and conditional IP69K.

SKU SICK-6035490 Category
SICK V18V

SICK VTE18-4N4240V Washdown Energetic Proximity Sensor

BrandSICK
Model IdentifierVTE18-4N4240V
Official Part Number6035490

Technical Overview

The SICK VTE18-4N4240V is a cylindrical energetic photoelectric proximity sensor for hygienic and washdown zones. It evaluates light reflected by a target from one mounting side, with a 5–400 mm sensing range and 0–450 mm maximum range specified using a white target at 90% remission. An 880 nm infrared LED produces a typical 60 mm spot at 400 mm. Manual Touch-Teach-in adjusts the sensing range, and an NPN output provides control-wire selection of light/dark switching. Response is ≤1 ms under resistive load, with 500 Hz operation at a 1:1 light/dark ratio. The V4A stainless-steel housing uses grade 1.4404/316L and an M12 four-pin connector. IP67/IP68 protection is specified; IP69K requires a correctly mounted IP69K connector.

Washdown energetic proximity sensor with 5–400 mm sensing range, 880 nm infrared LED, Touch-Teach-in, NPN output and a 316L housing.

Key Features

  • Energetic photoelectric proximity sensing from one side
  • 5–400 mm sensing range; 0–450 mm maximum on 90% remission white
  • 880 nm infrared LED; typical Ø60 mm spot at 400 mm
  • Manual Touch-Teach-in sensing-range adjustment
  • Axial optics; approximate 4.5° angle of dispersion
  • NPN light/dark switching selected through L/D control wire
  • ≤1 ms response with resistive load; 500 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 35 mA without load at 30 V DC
  • V4A stainless steel 1.4404/316L; M12 four-pin connector
  • IP67/IP68; IP69K with correctly mounted IP69K connector

Teach reflected-light detection from one mounting side and provide an NPN switching state for external transport or machine-sequence control.

Technical Specification Matrix

ParameterValue
Functional principleEnergetic photoelectric proximity sensing from target-reflected light
Maximum sensing range0–450 mm on 90% remission standard white target, DIN 5033
Sensing range5–400 mm
Light sourceInfrared LED
Wavelength880 nm
Light spot sizeTypically Ø60 mm at 400 mm
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentManual Touch-Teach-in; single sensing-range teach-in button
Special applicationHygienic and washdown zones
Digital outputNPN; maximum output current ≤100 mA
Switching modeLight/dark switching; selectable via L/D control wire; open wire selects dark switching
Signal voltage NPN HIGH/LOWApproximately supply voltage / <2.0 V
Response time≤1 ms signal transit time with resistive load
Switching frequency500 Hz at 1:1 light/dark ratio
Pin assignment1 BN=L+; 2 WH=L/D control; 3 BU=M; 4 BK=Q (CD-087)
Power supply10–30 V DC; limit values
Residual ripple±10%; remain within supply tolerances
Current consumption35 mA without load at supply 30 V DC
Protection classIII
Housing designCylindrical
Housing materialV4A stainless steel, 1.4404 / 316L
Optics materialFlat plastic optics; manufacturer lists PPS (Grilamid)
Mounting threadM18 × 1
ConnectionMale M12 four-pin connector; gold-plated contact pins; PPS with FDA certificate
IP ratingIP67/IP68; IP69K with correctly mounted IP69K connector
Operating temperature−25 to +80 °C; +100 °C permitted for maximum 15 minutes
Storage temperature−40 to +80 °C
Physical Weight (kg)0.12
Optical axisAxial
Angle of dispersionApproximately 4.5°

Industrial Applications

1. Confirming an opaque carrier at a washdown transfer

A washdown transfer can mount the sensor beside the expected position of an opaque carrier, using target-reflected infrared light from one side. Touch-Teach-in establishes detection with actual carrier surfaces and background spacing. External transfer logic evaluates the NPN state after testing wet and dry samples, target finish and position variation within the intended 5–400 mm sensing arrangement.

Problem Solved

A local carrier-presence reference helps external transfer control coordinate release of the next load, while one-sided detection avoids installing a reflector or receiver across the washed process area.

Washdown carrier Reflected infrared One-sided detection

2. Counting separated opaque packs on a conveyor

A conveyor can present separated opaque packs through a taught detection position so each pack changes the infrared return. External counting logic verifies package finish, tilt and gaps against representative samples rather than treating the white-reference maximum as guaranteed for every target. Integration checks controller sampling and the specified 500 Hz switching frequency at a 1:1 light/dark ratio.

Problem Solved

A target-reflected passage reference helps external counting logic track separated packs where one-sided installation is practical, supporting product-event association after real package surfaces and spacing have been checked.

Opaque packs Energetic sensing External counting

3. Checking an opaque component at a post-cleaning nest

A station downstream of cleaning can teach the sensor on an opaque component at its expected nest position. The energetic return is tested against the actual component finish, water films and surrounding background before external sequence control uses it as a presence reference. The 316L housing supports the stated washdown environment, with a correctly mounted IP69K connector when that rating is required.

Problem Solved

A component-present reference helps external sequence control recognize a missed arrival after cleaning, reducing the chance that the next operation starts without the expected part at the taught position.

Cleaned component Nest presence 316L housing
Select your currency