SICK 6026215 PNP Teach-in Diffuse Photoelectric Sensor

USD 166.14

VT12T-2P132 offers 2–300 mm reference-white sensing, 880 nm LED light, local/control-input teaching, selectable PNP switching and 2 m cable.

SKU SICK-6026215 Category
SICK V12-2

SICK VT12T-2P132 Teach-in Diffuse Photoelectric Sensor

BrandSICK
Model IdentifierVT12T-2P132
Official Part Number6026215

Technical Overview

The SICK VT12T-2P132 is a cylindrical energetic photoelectric proximity sensor that evaluates infrared light reflected from a nearby target. It provides 2–300 mm sensing on 90% remission reference white, with 0–340 mm maximum range. The 880 nm LED produces a 28 mm spot at 300 mm. A single button or control input C teaches sensitivity, and the PNP output supports light/dark selection through C. Response is no more than 1.25 ms with resistive load, with 400 Hz switching at a 1:1 light/dark ratio. The M12 × 1 threaded nickel-plated brass/PA housing uses PMMA optics, 2 m four-wire PVC cable and IP67 protection.

Energetic diffuse sensor with 2–300 mm reference-white range, local/control-input teaching, selectable PNP switching and 2 m four-wire PVC cable.

Key Features

  • Energetic proximity sensing from one mounting side
  • 2–300 mm sensing on 90% remission reference white
  • 0–340 mm maximum range on reference white
  • 880 nm infrared LED; Ø28 mm at 300 mm
  • Teach-in button and electronic teaching through C at 0 V
  • PNP output; light/dark selection through control input C
  • ≤1.25 ms response with resistive load; 400 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 20 mA consumption without load
  • 2 m four-wire PVC cable; nickel-plated brass/PA housing and PMMA optics
  • M12 × 1 threaded housing; IP67; −25 to +70 °C operation

Teach reflected-light detection using a local button or control input C, then connect the switching state to external machine control.

Technical Specification Matrix

ParameterValue
Functional principleEnergetic photoelectric proximity sensor
Sensing range2–300 mm on 90% remission reference white (DIN 5033)
Maximum sensing range0–340 mm on 90% remission reference white (DIN 5033)
Light sourceInfrared LED
Wavelength880 nm
Light spot sizeØ28 mm at 300 mm
Angle of dispersionApprox. 5.3°
LED service lifeAverage 100,000 h at +25 °C
AdjustmentSingle local teach-in button or electronic control input C (0 V)
Digital outputPNP switching output; maximum current ≤100 mA
Switching modeLight/dark switching, selectable via control input C
Response time≤1.25 ms signal transit time with resistive load
Switching frequency400 Hz at 1:1 light/dark ratio
Power supply10–30 V DC, limit values
Residual ripple±10%; remain within supply tolerances
Current consumption20 mA without load
Protection classIII
Circuit protectionA: supply reverse-polarity protection; B: inputs and output reverse-polarity protection; C: interference suppression; D: outputs overcurrent and short-circuit protection
Housing designCylindrical, M12 × 1 threaded housing
Housing materialNickel-plated brass / PA
Optics materialPMMA plastic
Connection2 m four-wire PVC cable; do not bend cable below 0 °C
Pin assignmentBN=L+; BU=M; BK=Q; WH=C (CD-100)
IP ratingIP67
Operating temperature−25 to +70 °C
Storage temperature−25 to +70 °C
Physical Weight (kg)0.054
Yellow LED indicatorContinuous: reception signal above reserve factor 2; blinking: below reserve factor 2 but above switching threshold 1
Reference-target rangesGray 18%: 2–180 mm sensing, 2–200 mm maximum
Conductor cross-section0.14 mm²
Cable diameterØ3.75 mm

Industrial Applications

1. Counting separated tabs at a component guide

A component guide can present separated tabs within the 2–300 mm white-target sensing range. Energetic optics evaluate light reflected from each tab, while local or electronic teaching establishes the working sensitivity. External counting logic evaluates the PNP output using the selected light/dark mode. Setup checks actual tab reflectance, spacing and transit speed against the optical response and switching limits.

Problem Solved

A tab-passage reference helps external counting logic register separated features from one mounting side, with teaching available to establish detection for the presented target condition.

Tab counting Sensitivity teaching Reflected-light sensing

2. Checking an insert in an assembly nest

An assembly nest can present a small insert at a repeatable distance facing the sensor. Button or electronic teaching establishes a reflected-light condition using representative assemblies. External inspection logic samples the switching output when the assembly is stationary. Actual insert material, background and placement tolerance are checked because energetic detection depends on the returned light level.

Problem Solved

An insert-present reference helps external inspection logic identify an empty assembly location before the next operation, using a taught reflected-light condition at a repeatable nest position.

Insert presence Assembly nest Electronic teaching

3. Confirming a carrier against a transfer stop

A transfer stop can bring a defined carrier surface into the sensor’s working distance. Energetic sensing and the taught sensitivity provide a discrete arrival condition, while control input C selects the required light/dark output behavior. External transfer logic samples the state after setup verifies actual carrier reflectance and seated gap, using the shorter gray-target ranges where relevant.

Problem Solved

A seated-carrier reference helps external transfer logic coordinate release at a compact stop, using light returned from a nearby surface and keeping the optical components on one mounting side.

Carrier arrival Transfer stop Selectable switching