| Measurement principle | HDDM+ time of flight |
| Target | Natural objects |
| Measuring range | 0.2–155 m at 6% remission; 0.2–460 m at 90% remission |
| Range conditions | Dependent on remission and measurement cycle time; specified with maximum 100 klux sunlight; upper ranges shown at 128 ms cycle |
| Data-interface resolution | Adjustable 1–100,000 µm; distinct from measurement accuracy |
| Repeatability | 1 mm or greater; statistical 1σ, constant environment, 6–90% remission and warm-up >about 15 min; depends on distance, cycle and filter settings |
| Measurement accuracy | Typical ±15 mm at +23 °C after >about 15 min warm-up; distance-dependent accuracy diagram also applies |
| Response time | 3–384 ms; depends on selected filters and measurement cycle |
| Measurement cycle time | Selectable 1, 4, 16, 64 or 128 ms |
| Output time | ≥1 ms; depends on interface |
| Laser class | 1; IEC 60825-1:2014 and EN 60825-1:2014 |
| Measuring-laser service life | Average 100,000 h at +25 °C |
| Typical light spot sizes | 5 × 20 mm at 1 m; 20 × 20 mm at 5 m; 35 × 25 mm at 10 m; 150 × 50 mm at 50 m; 290 × 80 mm at 100 m; 570 × 140 mm at 200 m |
| Filters | Rain and snow; fog; moving-average distance; Kalman; moving-average speed |
| Echo selection | Relevant distance and signal-level window; first or last echo within the selected window |
| Maximum movement speed | 128 m/s |
| Maximum object temperature | +1,400 °C; additional high-temperature filter required above +1,200 °C, reducing range limit by approximately 25% |
| Ethernet interface | TCP/IP; 10/100 Mbit/s; parameterization and measurement-data output |
| Serial interface | RS-422 switchable to SSI; RS-422 for parameterization/data, SSI for data output |
| Configurable I/O | In1/Q1: digital input OR output; QA/Q2: analog OR digital output; Q3/Q4: digital outputs; In2: digital input |
| Digital outputs | 2–4 push-pull PNP/NPN outputs; maximum 100 mA; short-circuit protected; switching voltage Vs−4 V |
| Digital inputs | Internal pull-down; HIGH minimum 13 V to Vs; LOW maximum 5 V; deactivate measuring laser, activate alignment laser or preset |
| Analog output | One 4–20 mA current output, 16 bit, when QA is configured; maximum load (Vs−7 V)/21.5 mA |
| Power supply | 18–30 V DC; reverse-polarity protected |
| Power consumption | ≤22 W with heating off; ≤35 W with heating on; both with external load |
| Ripple | ≤5 Vpp; remain within supply tolerances |
| Initialization time | >15 s |
| Display | Graphical resistive touch display and status LEDs |
| Connection 1 | M12 A-coded eight-pin; 1=Q1/In1, 2=L+, 3=RX−/CLK−, 4=RX+/CLK+, 5=TX−/Data−, 6=TX+/Data+, 7=M, 8=Q2/QA |
| Connection 2 | M12 A-coded five-pin; 1=NC, 2=Q3, 3=NC, 4=Q4, 5=In2 |
| Connection 4 | M12 D-coded four-pin female Ethernet; 1=TX+, 2=RX+, 3=TX−, 4=RX− |
| IP rating | IP65 and IP67 with suitable mating connectors fitted |
| Protection class | III, EN 61140 |
| Housing material | Aluminum alloy AlSi12 |
| Window material | Glass |
| Mounting | M5 threads |
| Operating ambient temperature | −40 to +55 °C standard; −40 to +95 °C with cooling case |
| Low-temperature warm-up | At −40 °C: typically 20 min with 24 V supply |
| Storage temperature | −40 to +75 °C |
| Relative humidity | ≤95%, noncondensing |
| Air-pressure effect | 0.3 ppm/hPa |
| Air-temperature effect | −1 ppm/K |
| Temperature drift | Typical 0.25 mm/K |
| Ambient-light immunity | Typical ≤100,000 lx |
| Mechanical shock | 30 g, 6 ms, six axes, DIN EN 60068-2-27 (Ea) |
| Continuous shock | 25 g, 6 ms, 500 shocks, six axes, DIN EN 60068-2-27 fatigue |
| MTTFD | 101 years |
| DCavg | 0% |
| Physical Weight (kg) | 0.98 |
| Dimensions L x W x H (cm) | 15.7 x 8.4 x 10.44 |