SICK 1040085 18 mm NPN NO Magnetic Proximity Sensor

USD 85.28

MM18-70ANS-ZUK provides 0–70 mm magnetic sensing with MAG-3010-B in non-magnetic mounting, NPN NO output, a 2 m PUR cable and IP67 protection.

SKU SICK-1040085 Category
SICK MME

SICK MM18-70ANS-ZUK NPN Magnetic Proximity Sensor

BrandSICK
Model IdentifierMM18-70ANS-ZUK
Official Part Number1040085

Technical Overview

The SICK MM18-70ANS-ZUK is an axially aligned magnetic proximity sensor with a short-body M18 × 1 nickel-plated brass housing. Its 0–70 mm sensing range applies to non-magnetic mounting material with the MAG-3010-B (M4.0) reference magnet; the assured switching distance is 56.7 mm and magnetic sensitivity is 0.7 mT. The NPN normally open output uses DC three-wire wiring and supports 5,000 Hz switching with continuous output current up to 200 mA. A 2 m three-wire PUR cable provides the connection. Operation uses 10–30 V DC, with IP67 protection and an ambient range of −40 to +75 °C. Temperature changes below −25 °C reduce service life, and the cable must be permanently installed below that temperature.

Axial M18 magnetic proximity sensor with 0–70 mm reference-magnet range, NPN NO output, 2 m three-wire PUR cable and IP67 protection.

Key Features

  • Axially aligned magnetic proximity sensing; M18 × 1 short-body housing
  • 0–70 mm sensing with MAG-3010-B (M4.0) in non-magnetic mounting material
  • 56.7 mm assured switching distance; 0.7 mT magnetic sensitivity
  • NPN normally open output; DC three-wire wiring; continuous current ≤200 mA
  • 5,000 Hz switching frequency
  • 2 m three-wire PUR cable
  • 10–30 V DC; 10 mA without load
  • Reverse-polarity, pulsed short-circuit and power-up pulse protection
  • Nickel-plated brass housing; IP67; two fastening nuts supplied
  • −40 to +75 °C operation; low-temperature service-life and fixed-cable conditions apply

Detect an approaching magnetic target with an NPN normally open signal, matching the magnet, alignment and mounting material to the specified sensing conditions.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic proximity sensing
Housing designMetric; short-body
Thread sizeM18 × 1
Body diameterØ18 mm
Sensing range Sn0–70 mm
Range reference conditionsMAG-3010-B (M4.0) magnet; sensor installed in non-magnetic material
Assured switching distance Sa56.7 mm
Magnetic sensitivity0.7 mT
Magnetic alignmentAxial
Other reference-magnet ranges0–85 mm: MAG-3315-B / MAG-3015-B; 0–38 mm: MAG-2006-B; 0–25 mm: MAG-0625-A; 0–24 mm: MAG-1003-S; maximum ranges shown for flush or non-flush installation in non-magnetic material
Switching frequency5,000 Hz
Digital outputNPN; normally open
Electrical wiringDC three-wire
Continuous output current≤200 mA
Connection2 m three-wire PUR cable
Power supply10–30 V DC
Ripple≤10% of supply voltage
Voltage drop≤2 V at maximum output current
Current consumption10 mA without load
Availability delay≤20 ms
Hysteresis1–10%
Reproducibility≤1% of Sr with supply voltage and ambient temperature constant
Temperature drift±10% of Sr
Protection functionsReverse polarity; pulsed short-circuit protection; power-up pulse protection
Housing materialNickel-plated brass
Housing length48 mm
Thread length32 mm
IP ratingIP67, EN 60529
Operating temperature−40 to +75 °C
Low-temperature conditionTemperature changes below −25 °C reduce service life; cable must be permanently installed below −25 °C
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
Items suppliedTwo fastening nuts
MTTFD1,980 years
DCavg0%
Mission time20 years
Cable materialPUR
Wire assignmentBN=L+; BK=NO output; BU=M (CD-001)
Installation drawing conditionsIn magnetizable mounting material, projection A=15 mm; drawing tightening limit <40 Nm

Industrial Applications

1. Confirming a carriage reaches a monitored position

A carriage can carry a suitable magnet so its field approaches the sensor axially at a selected position. The NPN normally open output supplies a discrete arrival condition to external sequencing logic. Setup verifies the actual magnet, gap, alignment and mounting material, using the reference-magnet range only where its stated conditions apply and checking surrounding magnetic influences.

Problem Solved

A magnetic arrival reference helps external sequencing logic recognize the carriage at a monitored position, reducing reliance on elapsed movement time before the next ordinary handling step.

Carriage arrival Magnetic target NPN output

2. Checking a magnet-equipped fixture is presented

A fixture can incorporate a suitable magnet that enters the sensor’s operating region when the fixture is correctly presented. External inspection logic samples the normally open output after seating. Commissioning checks the installed magnet, repeatable presentation gap and nearby materials, ensuring the expected magnetic field reaches the active face without relying on the fixture material itself as the sensing target.

Problem Solved

A magnet-present reference helps external inspection logic distinguish the intended fixture presentation from an empty station, supporting a presence check before further ordinary processing.

Fixture presence Axial field External inspection

3. Counting repeated magnet passages on a mechanism

A cyclic mechanism can carry separated magnets past the sensor so their fields produce repeated NPN output changes. An external counter evaluates those events. Setup checks magnet orientation, separation, active gap and movement rate against the specified sensing conditions and switching frequency, allowing the field to release between passages and accounting for other magnetic influences around the installation.

Problem Solved

Repeated magnetic-passage signals help external counting logic follow mechanism events or cycles, using a defined magnet arrangement and verified separation between successive output changes.

Cycle counting Magnet passages Discrete events
Select your currency