Technical Overview

The SICK DFS60B-S4CL01250 is an incremental encoder providing 1,250 pulses per revolution through six TTL/RS-422 signal channels. A 10 mm diameter stainless-steel solid shaft with flat and 19 mm shaft length supports mechanical coupling through a face-mount flange. The encoder uses a 3 m eight-wire universal cable that can be routed radially or axially without a bend at the outlet. A single 90° electrical reference signal is logically gated with A and B, with 40 ms initialization and output frequency up to 600 kHz. Supply is 10–32 V; the housing/cable side is IP67 and the shaft side IP65, with temperature limits depending on cable movement.

1,250 PPR incremental encoder with six TTL/RS-422 channels, 10 mm solid shaft, face-mount flange and 3 m eight-wire universal cable.

Key Features

  • 1,250 pulses per revolution; incremental TTL/RS-422 interface
  • Six channels: A, B, Z and their complements
  • Single reference signal, 90° electrical, logically gated with A and B
  • 40 ms initialization; ≤600 kHz output frequency; ≤30 mA load current
  • 10–32 V supply; ≤0.5 W consumption without load
  • 3 m eight-wire universal cable; radial or axial routing without an outlet bend
  • 10 mm diameter ×19 mm solid stainless-steel shaft with flat; face-mount flange
  • Aluminum flange; die-cast aluminum housing; 80 N radial / 40 N axial shaft load
  • ≤9,000 rpm mechanical speed with 3.3 K per 1,000 rpm self-heating allowance
  • IP67 housing/cable side and IP65 shaft side; operating temperature depends on stationary or flexible cable use

Supply incremental rotation and reference pulses through six TTL/RS-422 channels, with a universal cable outlet that supports radial or axial routing.

Technical Specification Matrix

ParameterValue
Encoder typeIncremental
Pulses per revolution1,250; observe manufacturer maximum-revolution-range diagram
InterfaceTTL / RS-422
Signal channelsSix: A, B, Z and complementary A, B, Z
Measuring step90° electrical divided by pulses per revolution
Measuring step deviation±0.01° for non-binary line counts
Error limits±0.05°
Initialization time40 ms
Output frequency≤600 kHz
Load current≤30 mA
Power consumption≤0.5 W without load
Power supply10–32 V
Reference signalOne; 90° electrical, logically gated with A and B
Connection3 m eight-wire universal cable; radial or axial routing without outlet bend
Wire assignmentBN=A complement; WH=A; BK=B complement; PK=B; YE=Z complement; VT=Z; BU=GND; RD=+US
Shield connectionScreen connected to encoder housing; connect to ground at control side
Cable drawingØ5.6 mm ±0.2 mm; 30 mm bend radius
Electrical protectionReverse-polarity protection; output short-circuit protection to another channel or GND for maximum 30 s
Mechanical designSolid shaft; face-mount flange
Shaft diameter and length10 mm diameter; 19 mm length; with flat
Shaft materialStainless steel
Flange materialAluminum
Housing materialDie-cast aluminum
Start-up torque0.5 Ncm at +20 °C
Operating torque0.3 Ncm at +20 °C
Permissible shaft load80 N radial; 40 N axial
Operating speed≤9,000 min⁻¹; observe resolution/speed diagram and thermal allowance
Speed-related self-heatingAllow 3.3 K per 1,000 rpm in operating-temperature design
Rotor inertia6.2 gcm²
Bearing lifetime3.6 × 10¹⁰ revolutions
Angular acceleration≤500,000 rad/s²
EMCEN 61000-6-2 and EN 61000-6-4
IP ratingIP67 housing side and cable connection; IP65 shaft side (IEC 60529)
Relative humidity90%; condensation not permitted
Operating temperature−40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable; account for speed-related self-heating
Storage temperature−40 to +100 °C without packaging
Shock resistance70 g, 6 ms; EN 60068-2-27
Vibration resistance30 g, 10–2,000 Hz; EN 60068-2-6
MTTFD300 years, EN ISO 13849-1; nominal component load, average ambient 40 °C, 8,760 h/year, electronic failures counted hazardous; standard product, not a safety component

Industrial Applications

1. Measuring conveyor drive speed

A conveyor drive can mechanically couple the solid shaft to a rotating member and feed the TTL/RS-422 channels to a compatible controller. External logic calculates speed from the 1,250 pulses per revolution and its sampling interval. Commissioning checks the actual coupling, shaft loads and controller bandwidth, while thermal design accounts for the stated speed-related self-heating.

Problem Solved

Incremental pulse feedback helps the controller measure conveyor drive rotation and compare observed speed with the intended operating condition through a known mechanical ratio.

Drive speed Pulse feedback TTL/RS-422

2. Tracking relative movement on a screw-driven axis

A screw-driven axis can couple the encoder shaft to the rotating screw or drive train. External counting logic uses the A and B channels to follow relative rotation and converts counts into travel using the actual screw pitch and coupling ratio. The reference signal supplies a once-per-revolution phase reference; establishing a unique machine position remains part of the external referencing sequence.

Problem Solved

Relative rotation feedback helps motion logic track axis movement through the known transmission ratio, with a reference pulse available for coordinating the machine’s external referencing sequence.

Relative travel Quadrature counting Reference pulse

3. Coordinating events on a rotary indexing mechanism

A rotary indexing mechanism can mechanically couple the encoder to its shaft and use incremental counts to schedule process events. The gated 90° electrical reference signal provides a repeatable phase marker within each revolution. External control establishes the required reference, then evaluates counts and direction against the intended event positions while respecting output-frequency, initialization and mechanical limits.

Problem Solved

A counted angular reference helps machine logic place repeated events within a rotation, using quadrature information and a defined reference pulse after the machine establishes its starting reference.

Rotary events Reference phase Incremental angle
Select your currency