SICK 1048811 miniTwin4 120 mm 14 mm Safety Light Curtain

USD 1,404.52

C4MT-01214ABB03BE0 offers a 120 mm protective field, 14 mm resolution, Type 4/SIL 3/PL e ratings, optical synchronization and standalone or end-guest use.

SKU SICK-1048811 Category
SICK Safety Light Curtains

SICK C4MT-01214ABB03BE0 miniTwin4 Safety Light Curtain

BrandSICK
Model IdentifierC4MT-01214ABB03BE0
Official Part Number1048811

Technical Overview

The SICK C4MT-01214ABB03BE0 is a miniTwin4 safety light curtain with 120 mm protective field height and 14 mm resolution. It is specified for standalone use or as the last guest in a two- or three-device cascade, with 0–4 m minimum scanning range and 0–5 m typical range. Optical synchronization avoids a separate synchronization connection. Type 4, SIL 3, category 4 and PL e ratings apply to the device; standalone response is no more than 14 ms, while cascade timing is determined separately. Restart interlock and external device monitoring are available but deactivated on delivery. The aluminum-alloy construction uses IP65 protection and M12 five-pin system connection on a 160 mm cable.

miniTwin4 safety light curtain with 120 mm field, 14 mm resolution, optical synchronization and standalone or final-guest cascade use.

Key Features

  • 120 mm protective field height; 14 mm resolution
  • 0–4 m minimum scanning-range specification; 0–5 m typical range
  • miniTwin4 standalone use or last guest in a two- or three-device cascade
  • Type 4, IEC 61496-1; SIL 3, IEC 61508; category 4 and PL e, EN ISO 13849
  • Standalone response ≤14 ms; cascade response determined separately
  • Optical synchronization; automatic beam coding; hard-wired configuration
  • Restart interlock and EDM supported, both deactivated on delivery
  • PNP semiconductor OSSDs, short-circuit protected and cross-circuit monitored; ≤300 mA per OSSD
  • 24 V DC nominal; M12 five-pin plug; 160 mm connection cable
  • Aluminum-alloy housing; IP65; C-Fix or L-Fix mounting; −20 to +55 °C operation

Monitor a compact protective field with 14 mm resolution and optical synchronization, using standalone operation or the documented final-guest cascade arrangement.

Technical Specification Matrix

ParameterValue
Product familyminiTwin4 safety light curtain
Protective field height120 mm
Resolution14 mm
Minimum scanning-range specification0–4 m
Typical scanning range0–5 m
System usageStandalone device or last guest in a two- or three-device cascade
Response time≤14 ms for standalone device only; consult operating instructions for cascade timing
SynchronizationOptical, without separate synchronization connection
MountingC-Fix or L-Fix brackets
TypeType 4, IEC 61496-1
SILSIL 3, IEC 61508
CategoryCategory 4, EN ISO 13849
Performance levelPL e, EN ISO 13849
PFHDStandalone system: 4.3 × 10⁻⁹ per hour, EN ISO 13849
Mission time20 years, EN ISO 13849
Fault stateAt least one OSSD is OFF
Restart interlockSupported; deactivated on delivery
External device monitoringSupported; deactivated on delivery
Beam codingAutomatic
Configuration methodHard wired
System connectionM12 five-pin plug on 160 mm cable
Conductor cross-section0.34 mm²
Permitted cable length≤20 m depending on load, power supply and conductor cross-section; observe technical limits
System pin assignmentConnection example: 1=+24 V DC; 2=Mtfkp; 3=0 V; 4=OSSD; 5=FE
Power supply24 V DC nominal; 19.2–28.8 V DC
Ripple≤10% within supply-voltage limits
Protection classIII, EN 61140
OSSD typePNP semiconductors, short-circuit protected and cross-circuit monitored over −30 to +30 V
OSSD HIGH voltageNominal 24 V DC; supply voltage −2.25 V to supply voltage
OSSD LOW voltage≤2 V DC
OSSD current capacity≤300 mA per OSSD
Housing materialAluminum alloy AlMgSi 0.5
Housing cross-section15 × 32 mm including system connection; cross-section only
IP ratingIP65, EN 60529
Operating temperature−20 to +55 °C
Storage temperature−25 to +70 °C
Humidity15–95%, non-condensing
Vibration resistance5–150 Hz, 3.5 mm / 1 g; EN 60068-2-6
Shock resistance15 g / 6 ms, EN 60068-2-27; class 3M4, IEC TR 60721-4-3
Wavelength850 nm
DisplayLEDs
Included itemsTwin stick; system plug; two C-Fix and two L-Fix brackets; test rod matched to resolution; safety and mounting instructions; operating instructions available for download

Industrial Applications

1. Monitoring a small opening at a hand-fed station

A hand-fed station can position the 120 mm protective field across a defined small access opening, using the 14 mm resolution to monitor interruptions. Compatible safety-related control evaluates the OSSDs and brings the hazardous motion to the required state. Machine design checks access around the field, stopping time and protective distance, then validates the complete safeguard for the actual feeding task.

Problem Solved

An optical protective-field input supports safety-related control at a compact access point, while the machine’s validated geometry and stopping behavior determine the safeguarding arrangement.

Compact access 14 mm resolution OSSD evaluation

2. Monitoring the final opening of a cascade arrangement

A machine with several access points can use this configuration as the last guest in a compatible two- or three-device miniTwin4 cascade. Its 120 mm field monitors the selected final opening and optical synchronization supports the sensing arrangement. Design uses the cascade response time from the operating instructions, rather than the standalone ≤14 ms value, before calculating and validating the required protective distances.

Problem Solved

A documented final-guest configuration helps integrate a compact protective field into a multi-device arrangement, with cascade-specific timing used to validate the complete machine safeguard.

Final guest Cascade timing Multiple access points

3. Configuring restart and contactor monitoring for a station

A compact machine station can integrate the curtain with compatible safety-related logic and controlled output devices. Restart interlock and external device monitoring are supported, but both are deactivated on delivery, so commissioning establishes the intended configuration. Functional checks verify the protective-field interruption, required reset behavior and monitored output-device response before the machine’s safeguarding function is released for use.

Problem Solved

Available restart and EDM functions support the selected control arrangement when configured and validated, helping align reset behavior and output-device feedback with the station’s safeguarding requirements.

Restart configuration EDM Commissioning checks