Technical Overview

The SICK DFS60B-S1PL10000 is a programmable incremental encoder providing 10,000 pulses per revolution through six TTL/HTL channels, with TTL set at the factory. It uses a 6 mm solid shaft with flat and servo flange and a 3 m eight-wire universal cable. A single reference signal is stated at 90° electrical, gated with A and B, while electrical zero-pulse widths of 90°, 180° or 270° and mechanical widths from 1° to 359° are configurable. The encoder operates from 4.5–32 V with output frequency up to 600 kHz and consumption no more than 0.7 W without load. The housing/cable side is rated IP67; the shaft side is IP65, with temperature and speed limits considered together.

10,000 PPR incremental encoder with six TTL/HTL channels, 6 mm solid shaft with flat and servo flange and 3 m eight-wire universal cable.

Key Features

  • 10,000 pulses per revolution; incremental TTL/HTL interface
  • Six channels: A, B, Z and complementary A, B, Z
  • Programmable/configurable; factory output level TTL; ≤600 kHz output frequency
  • Electrical zero width 90°/180°/270°; mechanical zero width 1°–359° configurable
  • 6 mm solid shaft with flat and servo flange
  • 3 m eight-wire universal cable
  • 4.5–32 V supply; ≤0.7 W without load; ≤30 mA load current
  • Stainless-steel shaft; aluminum flange; die-cast aluminum housing
  • ≤9,000 rpm mechanical speed; allow 3.3 K self-heating per 1,000 rpm
  • IP67 housing/cable side; IP65 shaft side; operating temperature depends on cable movement

Provide incremental rotation and reference pulses to compatible machine control, with configurable TTL/HTL output and zero-pulse width.

Technical Specification Matrix

ParameterValue
Encoder typeIncremental
Pulses per revolution10,000; observe manufacturer resolution/speed diagram
InterfaceTTL/HTL
Signal channelsSix: A, B, Z and their complements
Measuring step90° electrical divided by pulses per revolution
Measuring-step deviation±0.01° for non-binary line counts
Error limits±0.05°
Initialization time32 ms; 30 ms with mechanical zero-pulse width
Output frequency≤600 kHz
Load current≤30 mA
Power consumption≤0.7 W without load
Power supply4.5–32 V
Reference signalOne; 90° electrical, logically gated with A and B
Connection3 m eight-wire universal cable
Reverse-polarity protectionProvided
Short-circuit protectionTTL at supply ≥5.5 V: to another channel or GND, maximum 30 s; HTL or TTL at supply <5.5 V: to another channel, supply or GND, maximum 30 s
Mechanical design6 mm solid shaft with flat and servo flange
Shaft materialStainless steel
Flange materialAluminum
Housing materialDie-cast aluminum
Start-up torque0.5 Ncm at +20 °C
Operating torque0.3 Ncm at +20 °C
Operating speed≤9,000 min⁻¹, mechanical limit
Resolution and speed limitObserve manufacturer resolution/speed diagram and output-frequency limit; mechanical speed is not an unconditional maximum at every programmed resolution
Speed-related self-heatingAllow 3.3 K per 1,000 rpm in operating-temperature design
Rotor inertia6.2 gcm²
Bearing lifetime3.6 × 10¹⁰ revolutions
Angular acceleration≤500,000 rad/s²
EMCEN 61000-6-2 and EN 61000-6-3
IP ratingIP67 housing side and cable connection; IP65 shaft side
Relative humidity90%; condensation not permitted
Operating temperature−40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable; account for speed-related self-heating
Storage temperature−40 to +100 °C, without packaging
Shock resistance70 g, 6 ms; EN 60068-2-27
Vibration resistance30 g, 10–2,000 Hz; EN 60068-2-6
MTTFD300 years, EN ISO 13849-1; nominal component load, average ambient 40 °C, 8,760 h/year; electronic failures counted hazardous; standard product, not a safety component
Shaft diameter and length6 mm diameter with flat; 10 mm length
Permissible shaft load80 N radial; 40 N axial
Programmable/configurableYes; factory output level TTL
Electrical zero-pulse width90° gated with A and B; 180° gated with A or with B; 270° gated with A or B
Mechanical zero-pulse width1°–359° relative to one mechanical revolution
Wire assignmentBN=A complement; WH=A; BK=B complement; PK=B; YE=Z complement; VT=Z; BU=GND; RD=+US
Shield connectionScreen connected to encoder housing; connect to ground at control side
Cable drawingØ5.6 mm ±0.2 mm; 30 mm bend radius
Cable routingUniversal outlet permits radial or axial routing without a bend at the outlet

Industrial Applications

1. Measuring the speed of a conveyor drive

A conveyor drive can mechanically couple the encoder to a rotating member and feed its six TTL/HTL channels to compatible control hardware. External logic calculates speed from 10,000 pulses per revolution and its sampling interval. Commissioning verifies the actual shaft arrangement, input bandwidth and thermal conditions, including the specified speed-related self-heating allowance.

Problem Solved

Incremental rotation pulses help the controller measure actual drive speed and compare it with the intended conveyor condition, using the known mechanical coupling ratio.

Drive speed Incremental pulses TTL/HTL

2. Tracking relative travel on a screw-driven axis

A screw-driven axis can mechanically couple the encoder to its rotating drive train and use A/B quadrature counts to track movement. External motion logic converts counts into travel through the actual screw pitch and transmission ratio. The once-per-revolution reference pulse can support the machine’s referencing sequence; establishing a unique machine position remains part of the external control design.

Problem Solved

Relative rotation feedback helps motion logic track successive movements through the known transmission ratio, with a reference pulse available for coordinating the machine’s referencing sequence.

Relative travel Quadrature counts Reference pulse

3. Coordinating events on a rotary mechanism

A rotary mechanism can use incremental counts and the reference signal to place repeated process events within a turn. External control establishes the initial machine reference, then evaluates A/B direction and pulse count against the intended event positions. Setup checks initialization time, output frequency and mechanical limits before applying the selected reference-pulse configuration to the actual mechanism.

Problem Solved

A counted angular reference helps machine logic schedule repeated events within a rotation, using direction information and a reference pulse after the initial position has been established.

Rotary events Reference phase External sequencing