Technical Overview

The SICK UE410-XU4T5 is a Flexi Classic safety I/O expansion module configured by rotary switches. It provides four safety inputs, four switching inputs, four safety outputs and two test outputs, with an output delay of 0–5 s for Q3/Q4. Available functions include configurable manual or automatic restart interlock, external device monitoring, AND/OR operation, bypass and muting with zero or two muting sensors. The module’s stated ratings are SIL 3, category 4 and PL e, with complete machine performance determined by the validated system design. Plug-in spring terminals connect the module, which uses a 24 V DC PELV/SELV supply within 19.2–30 V and requires supply current limited to 4 A maximum.

Rotary-configured Flexi Classic safety I/O expansion module with four safety inputs, four safety outputs, two test outputs and 0–5 s Q3/Q4 delay.

Key Features

  • Flexi Classic safety I/O expansion module; rotary-switch configuration
  • Four safety inputs and four switching inputs
  • Four safety outputs and two test outputs
  • Q3/Q4 output delay adjustable from 0–5 s
  • SIL 3, category 4 and PL e component ratings; PFHD 2.5 × 10⁻⁹ per hour
  • Manual/automatic restart interlock; external device monitoring
  • AND/OR, bypass and muting functions; zero or two muting sensors
  • Plug-in spring terminals and LED indication
  • 24 V DC nominal, 19.2–30 V PELV/SELV; supply current limited to maximum 4 A
  • Housing IP40; terminals IP20; −25 to +55 °C operation

Expand a compatible Flexi Classic system with configurable safety I/O, external device monitoring and delayed Q3/Q4 outputs, using a validated machine-specific configuration.

Technical Specification Matrix

ParameterValue
Module typeFlexi Classic safety I/O expansion module
ConfigurationRotary switches
Safety inputs4
Switching inputs4
Safety outputs4
Test outputs2
Output delayQ3/Q4: 0–5 s
Restart interlockManual / automatic, configurable
External device monitoringEDM provided
Logic functionsAND and OR
Additional functionsBypass and muting
Muting sensors0 or 2
Safety integrity levelSIL 3, IEC 61508
Category4, EN ISO 13849
Performance levelPL e, EN ISO 13849
PFHD2.5 × 10⁻⁹ per hour, EN ISO 13849
Mission time20 years, EN ISO 13849
System integrationI/O expansion module within a compatible Flexi Classic system; required main module and configuration selected for the complete application
ConnectionPlug-in spring terminals
DisplayLEDs
Protection classIII, EN 61140
Supply terminalsA1 and A2
Supply typePELV or SELV; power supply current limited to maximum 4 A by the supply or a fuse
Power supply24 V DC nominal; 19.2–30 V DC
Residual ripple≤10%
Power consumption≤3 W DC
Internal power consumption≤3 W DC
Housing IP ratingIP40, EN 60529
Terminal IP ratingIP20, EN 60529
Operating temperature−25 to +55 °C
Storage temperature−25 to +70 °C
Air humidity≤95%, non-condensing
Climate conditionsEN 61131-2; +55 °C operating ambient and 95% relative humidity
EMCClass A; EN 61000-6-2 and EN 55011
Vibration resistance5 g RMS, 5–500 Hz; EN 60068-2-64
Physical Weight (kg)0.18

Industrial Applications

1. Adding safety I/O to a configured machine system

A compatible Flexi Classic system can use the expansion module to connect additional safety inputs and provide the corresponding configured safety outputs. Rotary switches establish the intended function, while the complete system design selects compatible devices, wiring and required main-module arrangement. Commissioning validates input behavior, output response and fault handling against the machine risk assessment and required safety performance.

Problem Solved

Additional safety I/O helps the machine designer incorporate more monitored devices into a compatible control arrangement, with achieved safety performance established through the complete validated system.

Safety I/O expansion Rotary configuration System validation

2. Coordinating delayed outputs in a stopping sequence

A machine stopping sequence can assign the Q3/Q4 outputs a delay within the specified 0–5 s range when that behavior is required by the validated safety design. The configured Flexi Classic system evaluates its inputs and controls the connected output devices. Commissioning checks the actual delay, external device monitoring, stopping behavior and restart conditions with the installed equipment.

Problem Solved

Configurable delayed outputs help implement an engineered stopping sequence, while the selected timing and external device behavior are verified against the complete machine safety requirement.

Delayed outputs Stopping sequence External device monitoring

3. Evaluating a material-transfer muting configuration

A material-transfer application can use the module’s muting function within a compatible configured Flexi Classic system, with the documented zero-or-two muting-sensor arrangement selected for the design. The system designer establishes sensor placement, signal evaluation and the permitted transfer condition. Commissioning validates the resulting behavior, including foreseeable access conditions and restoration of the protective function, for the complete machine installation.

Problem Solved

Available muting functionality gives the designer a basis for controlled material-transfer logic, with sensor arrangement and protective behavior established by the validated application rather than the module alone.

Muting configuration Material transfer Application validation
Select your currency