1. Monitoring opening of an access guard
An access guard can carry a separately selected compatible actuator that engages the switch when the guard is closed. Opening the guard withdraws the actuator and changes the positive-action N/C and N/O contact states. Connected safety-related logic evaluates the individually wired contacts and performs fault detection, with the complete interlocking design and machine stop behavior validated for the actual installation.
Problem Solved
A guard-position input helps connected safety-related logic recognize an opened access guard and enforce the machine response defined for the interlock, using external diagnostics.
Access guard
Positive-action contact
External safety logic
2. Checking a removable cover before machine restart
A removable cover can use a compatible separately selected actuator to present the intended contact pattern when refitted. Connected safety-related logic checks the switch state before accepting the restart condition. Setup verifies actuator engagement, approach direction and speed, low coding and the machine’s complete interlocking arrangement, with no reliance on internal fault detection by the switch.
Problem Solved
A cover-position reference helps the connected safety-related logic assess the refitted condition before restart, with the actuator and external diagnostics selected for the validated installation.
Cover position
Restart condition
Actuator engagement
3. Planning a repeatedly operated guard interlock
A frequently opened guard can use the switch within its stated actuation-frequency, approach-speed and retaining-force limits. The designer checks the actual duty against the mechanical-life and small-load B10d data while selecting the external safety logic and circuit loading. Commissioning verifies the complete interlock behavior, and maintenance planning considers actual cycling and environmental conditions.
Problem Solved
Documented mechanical and contact-life data help the designer assess a repeatedly operated interlock, with actual duty and external safety diagnostics included in the complete application evaluation.
Guard cycling
Mechanical duty
Maintenance planning