Technical Overview

The SICK i12-SA113 is an electro-mechanical safety switch with one positive-action normally closed contact and one normally open contact. Its slow-action switching element supports five actuation directions, with approach speed no more than 10 m/min, actuation frequency up to 7,200 per hour and retaining force no more than 6 N. The type 2 device has low actuator coding to EN ISO 14119; its actuator is ordered separately. It requires individual wiring and fault detection by connected safety-related logic because the switch has no internal fault detection. An M16 cable entry accepts conductors up to 1.5 mm², while the glass-fiber reinforced thermoplastic housing provides IP67 protection and −20 to +80 °C operation.

Type 2 safety switch with one positive-action N/C and one N/O contact, M16 cable entry and five actuation directions; actuator not supplied.

Key Features

  • Electro-mechanical safety switch; actuator not supplied
  • One positive-action N/C contact and one N/O contact
  • Slow-action switching element; five actuation directions
  • Approach speed ≤10 m/min; actuation frequency ≤7,200 per hour
  • Retaining force ≤6 N; mechanical life 1 × 10⁶ cycles
  • Type 2 and low coding level to EN ISO 14119
  • B10d 2 × 10⁶ switching cycles at small load
  • No internal fault detection; individual wiring and external safety-related diagnostics
  • One M16 cable entry; conductor cross-section ≤1.5 mm²
  • IP67 glass-fiber reinforced thermoplastic housing; −20 to +80 °C operation and storage

Monitor a separately selected actuator through positive-action N/C and N/O contacts, with individual wiring and fault diagnostics performed by connected safety-related logic.

Technical Specification Matrix

ParameterValue
Sensor principleElectro-mechanical safety switch
Safety contactsOne positive-action N/C contact and one N/O contact
Switching principleSlow-action switching element
Actuation directions5
Approach speed≤10 m/min
Actuation frequency≤7,200 per hour
Retaining force≤6 N
Device typeType 2, EN ISO 14119
Coding levelLow coding, EN ISO 14119
B10d2 × 10⁶ switching cycles at small load
Fault detectionNo internal fault detection; switch cannot assume a safe state on a fault by itself; fault detection performed by connected safety-related logic
Wiring arrangementIndividual wiring with diagnostics; no safe series connection
ConnectionOne M16 cable gland / entry
Conductor cross-section≤1.5 mm²
Usage categoryAC-15 / DC-13, IEC 60947-5-1
Rated operating current3 A at 240 V AC; 2 A at 24 V DC
Rated insulation voltage240 V
Rated impulse withstand voltage2,500 V AC
Short-circuit protectionT10/10A, as specified by manufacturer
Minimum switching voltage≥5 V DC
Switching current at stated voltage5 mA at 5 V DC
Housing materialGlass-fiber reinforced thermoplastic
Mechanical life1 × 10⁶ switching cycles
IP ratingIP67, IEC 60529
Operating temperature−20 to +80 °C
Storage temperature−20 to +80 °C
DeliveryActuator not supplied; select compatible actuator separately
Physical Weight (kg)0.08

Industrial Applications

1. Monitoring opening of an access guard

An access guard can carry a separately selected compatible actuator that engages the switch when the guard is closed. Opening the guard withdraws the actuator and changes the positive-action N/C and N/O contact states. Connected safety-related logic evaluates the individually wired contacts and performs fault detection, with the complete interlocking design and machine stop behavior validated for the actual installation.

Problem Solved

A guard-position input helps connected safety-related logic recognize an opened access guard and enforce the machine response defined for the interlock, using external diagnostics.

Access guard Positive-action contact External safety logic

2. Checking a removable cover before machine restart

A removable cover can use a compatible separately selected actuator to present the intended contact pattern when refitted. Connected safety-related logic checks the switch state before accepting the restart condition. Setup verifies actuator engagement, approach direction and speed, low coding and the machine’s complete interlocking arrangement, with no reliance on internal fault detection by the switch.

Problem Solved

A cover-position reference helps the connected safety-related logic assess the refitted condition before restart, with the actuator and external diagnostics selected for the validated installation.

Cover position Restart condition Actuator engagement

3. Planning a repeatedly operated guard interlock

A frequently opened guard can use the switch within its stated actuation-frequency, approach-speed and retaining-force limits. The designer checks the actual duty against the mechanical-life and small-load B10d data while selecting the external safety logic and circuit loading. Commissioning verifies the complete interlock behavior, and maintenance planning considers actual cycling and environmental conditions.

Problem Solved

Documented mechanical and contact-life data help the designer assess a repeatedly operated interlock, with actual duty and external safety diagnostics included in the complete application evaluation.

Guard cycling Mechanical duty Maintenance planning