SICK 1058276 WL4SLG-3P5232H Hygienic Laser Sensor

USD 390.26

WL4SLG-3P5232H offers Class 1 laser retro-reflective sensing, transparent-object detection, complementary PNP outputs, teach-in and an M8 four-pin connector.

SKU SICK-1058276 Category
SICK W4SLG-3H

SICK WL4SLG-3P5232H Hygienic Laser Retro-reflective Sensor

BrandSICK
Model IdentifierWL4SLG-3P5232H
Official Part Number1058276

Technical Overview

The SICK WL4SLG-3P5232H is a hygienic photoelectric retro-reflective sensor for transparent and small objects. Polarized coaxial optics operate without a minimum reflector distance, with 0–2 m sensing and 0–4.5 m maximum range on REF-AC1000 tape. Its Class 1 red laser produces a 1 mm spot at 500 mm, and a single teach-in button establishes the detection setting. Complementary PNP outputs provide light/dark switching, with Q assigned to light switching. The slim V4A stainless-steel housing has a D12 adapter shaft, PMMA front screen and M8 four-pin connection. Standard operation is −10 to +50 °C; extended temperatures require the specified startup, supply and output-current conditions.

Hygienic Class 1 laser retro-reflective sensor with coaxial optics, teach-in, complementary PNP outputs, D12 adapter shaft and M8 four-pin connection.

Key Features

  • Polarized retro-reflective sensing with coaxial optics and no minimum reflector distance
  • REF-AC1000: 0–2 m sensing; 0–4.5 m maximum range
  • 650 nm visible red Class 1 laser; Ø1 mm spot at 500 mm
  • Single teach-in button; received-light and supply indicators
  • Complementary PNP outputs; Q is light switching
  • Response ≤0.5 ms with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • Hygienic slim V4A 1.4404/316L stainless-steel housing and PMMA front screen
  • D12 adapter shaft; M8 four-pin male connector; maximum connector tightening torque 0.6 Nm
  • IP66/IP67/IP68/IP69K; IP69K requires correctly mounted IP69K connecting cable
  • −10 to +50 °C standard operation; extended −30 to +55 °C subject to specified conditions

Teach a returned-beam condition for transparent or small targets using coaxial laser optics and complementary PNP signals for external process logic.

Technical Specification Matrix

ParameterValue
Functional principlePolarized photoelectric retro-reflective sensor
Optical arrangementAutocollimation/coaxial optics; no minimum reflector distance
Sensing range0–2 m on REF-AC1000 reflective tape
Maximum sensing range0–4.5 m on REF-AC1000 reflective tape
Reflector-specific rangesPLV14-A / PLH25-M12 / PLH25-D12: 0–1.8 m sensing, 0–4 m maximum; P41F / REF-AC1000: 0–2 m sensing, 0–4.5 m maximum
Reflector selectionUse REF-AC1000 or reflectors based on it, such as P41F, PLV14-A, PLH25-M12 or PLH25-D12; large-scale triple-structure reflectors require application suitability checks
Light sourceVisible red laser; average service life 50,000 h at +25 °C
Wavelength650 nm
Laser class1; EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 and 1040.11
Light spot sizeØ1 mm at 500 mm
AdjustmentSingle teach-in button
Application areasHygienic and washdown zones; transparent-object detection; small-object detection
Switching outputPNP, complementary Q and Q complement
Switching modeLight/dark switching; Q is light switching
Output current≤100 mA; at ambient ≥+50 °C, maximum 50 mA and supply ≤24 V
Response time≤0.5 ms signal transit time with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC, limit values in short-circuit protected network maximum 8 A; at ambient ≥+50 °C, maximum 24 V
Ripple<5 Vpp; remain within supply-voltage limits
Current consumption30 mA without load
Protection classIII
Circuit protectionSupply and input/output reverse-polarity protection; interference suppression
ConnectionM8 four-pin male connector; maximum tightening torque 0.6 Nm
Pin assignmentCD-083: 1 BN=L+; 2 WH=Q complement; 3 BU=M; 4 BK=Q
Mounting featureD12 adapter shaft
HousingSlim rectangular hygienic design; V4A stainless steel 1.4404 / 316L
Front screen materialPMMA plastic
IP ratingIP66 / IP67 / IP68 / IP69K; IP69K only with correctly mounted IP69K connecting cable
Operating temperature−10 to +50 °C standard range
Extended operation−30 to +55 °C; at ambient ≥+50 °C, supply ≤24 V and load ≤50 mA. Below −10 °C, sensor must already be on above −10 °C, cool down while continuously powered and remain powered; switching on below −10 °C is not permitted
Storage temperature−30 to +70 °C
IndicatorsYellow: received beam status; green: supply active
MTTFD655 years, EN ISO 13849-1; parts-count calculation
Diagnostic coverageDCavg 0%
Physical Weight (kg)0.14

Industrial Applications

1. Counting transparent containers in a washdown area

A washdown conveyor can present separated transparent containers between the sensor and a suitable reflector. Teaching establishes the received-light condition for the actual material, wall thickness and separation. The compatible controller reads a complementary PNP state as containers pass, while commissioning checks contrast margin, transit timing, connector protection and cleaning compatibility for the hygienic installation.

Problem Solved

A transparent-container passage reference helps external counting logic recognize separated loads, using taught detection, suitable reflection and checked environmental conditions at the installed location.

Transparent containers Washdown installation Complementary PNP

2. Detecting a small component at a defined nest

A machine nest can position a small component through the returned laser path, using the specified 1 mm spot at 500 mm as an optical setup reference. Coaxial optics support arrangements without a minimum reflector distance. Setup checks actual component geometry and reflectivity, teaches the detection condition and verifies the complementary output transitions before external sequencing uses the presence signal.

Problem Solved

A small-component presence reference helps external sequencing logic check loading at a repeatable nest, with actual target geometry and laser-path alignment verified during setup.

Small component Coaxial optics Presence check

3. Confirming a transparent web across a feed path

A transparent web feed can pass between the sensor and a suitable reflective target so missing material changes the taught optical condition. External monitoring evaluates a complementary PNP state after commissioning verifies the actual film, reflector, alignment and web motion. The specified response and switching rate guide checks of the smallest interruption that the installed arrangement must recognize.

Problem Solved

A changed web-presence signal helps external feed monitoring recognize missing material at the sensing point, using taught optical contrast and verified timing for the actual film.

Transparent web Feed monitoring Output timing
Select your currency