SICK 6041803 VTF180-2P42412 PNP Focused-optics Sensor

USD 73.84

VTF180-2P42412 offers focused 645 nm red-light sensing, 1–100 mm reference-white range, PNP output, 270° adjustment and an M12 four-pin connector.

SKU SICK-6041803 Category
SICK V180-2

SICK VTF180-2P42412 PNP Focused-optics Energetic Sensor

BrandSICK
Model IdentifierVTF180-2P42412
Official Part Number6041803

Technical Overview

The SICK VTF180-2P42412 is an axial energetic photoelectric proximity sensor with focused optics and a PNP output. Reference-white sensing spans 1–100 mm, with a 1–140 mm maximum range; the specified gray target has a shorter range. Its 645 nm red LED produces an 8 mm spot at 100 mm. A 270° potentiometer adjusts detection, while an L/D control input selects light/dark behavior; an open control wire gives dark switching. Response is no more than 0.5 ms with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The IP67 nickel-plated brass/PC housing has PMMA optics, an M18 × 1 thread and an M12 four-pin connector. Two metal fastening nuts are supplied.

Focused-optics energetic sensor with 1–100 mm reference-white sensing, PNP output, L/D control input, M12 four-pin connector and metal M18 housing.

Key Features

  • Axial energetic photoelectric proximity sensing with focused optics
  • 1–100 mm sensing; 1–140 mm maximum range on reference white
  • 645 nm red LED; Ø8 mm spot at 100 mm
  • 270° detection potentiometer
  • PNP output; ≤100 mA; L/D control input, open wire gives dark switching
  • ≤0.5 ms response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 30 mA without load; M12 four-pin male connector
  • M18 × 1 nickel-plated brass/PC housing; PMMA optics; IP67
  • Two metal fastening nuts supplied, 24 mm across flats
  • −25 to +55 °C operation; −40 to +70 °C storage

Adjust focused reflected-light detection for a close presented target and select PNP light/dark behavior through the L/D control input for external process logic.

Technical Specification Matrix

ParameterValue
Functional principleEnergetic photoelectric proximity sensor
Optical designAxial focused optics
Sensing range1–100 mm on 90% remission reference white (DIN 5033)
Maximum sensing range1–140 mm on 90% remission reference white (DIN 5033)
Light sourceVisible red LED
Wavelength645 nm
Light spot sizeØ8 mm at 100 mm
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentPotentiometer, 270°, for detection adjustment
Switching outputPNP
Switching modeLight/dark switching via L/D control input; open control wire gives dark switching (D.ON)
Signal voltage HIGH/LOWApproximately supply voltage −1.8 V / 0 V
Output current≤100 mA
Response time≤0.5 ms with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A
Ripple±10%; remain within supply tolerances
Current consumption30 mA without load
ConnectionM12 four-pin male connector
Pin assignmentCD-087: 1 BN=L+; 2 WH=L/D; 3 BU=M; 4 BK=Q
Circuit protectionA: supply reverse-polarity protection; B: inputs and output reverse-polarity protection; D: outputs overcurrent and short-circuit protection
Protection classIII
Housing materialNickel-plated brass and PC
Optics materialPMMA plastic
Mounting threadM18 × 1
IP ratingIP67
Items suppliedTwo metal fastening nuts, 24 mm across flats
IndicatorsOrange: switching output active; green: strength indicator
Operating temperature−25 to +55 °C
Storage temperature−40 to +70 °C
UL filesNRKH2.E300503 and NRKH8.E300503
MTTFD1,884 years
DCavg0%
Reference-target rangesSensing / maximum: white 90% 1–100 / 1–140 mm; gray 18% 30–75 / 30–95 mm
Physical Weight (kg)0.047

Industrial Applications

1. Confirming a component in an assembly fixture

An assembly fixture can present a component surface at a repeatable gap facing the axial optical head. Sensitivity is adjusted using representative parts, and external inspection logic reads a PNP output after the component settles. Setup checks actual reflectance, placement tolerance and the empty-fixture response because energetic sensing depends on returned light from the presented target.

Problem Solved

A component-present reference helps external inspection logic distinguish an occupied fixture from an empty location, using sensitivity and geometry checked for the actual part surface.

Fixture inspection Energetic sensing PNP signals

2. Counting separated parts on a guide

A parts guide can move separated components through the sensor’s adjusted working gap and feed switching transitions to external counting electronics. Commissioning checks the darkest expected surface, part coverage and guide reflections with representative material. The feed speed and gaps are then checked against the documented response time and switching-frequency conditions before accepting passage events.

Problem Solved

A defined optical passage signal helps external counting electronics register separated parts, using an adjusted sensing point and timing checks for the actual parts feed.

Parts counting Reflectance checks Timing checks

3. Checking opaque strip continuity at a feed point

A material feed can keep a repeatable opaque strip surface within the adjusted energetic sensing gap while external process logic monitors its presence. Installation checks returned light from the actual strip, the empty path and nearby machine surfaces. Commissioning also verifies strip movement, gap tolerance and output loading so a missing strip produces a distinguishable process signal.

Problem Solved

A strip-presence reference helps external process logic recognize loss of feed at the checked location, using sensitivity and returned-light conditions established for the actual material path.

Strip continuity Material presence External process logic