$ 99.36
| Main Information | |
| Part Number | XY2CD111 |
| Product Series | Telemecanique Emergency stop rope pull switches XY2C |
| product type | Simple Pull Rope Switch |
| product short name | XY2CD |
| shell color | Orchid |
| Type of overvoltage | Class I conforming to EN/IEC 61140 |
| Class I conforming to NF C 20-030 | |
| Additional information | |
| cable length | 6 meters |
| body material | Zamak |
| head material | Plastic |
| Rated supply voltage [Us] | 240V |
| contact type | 1 NC + 1 NO |
| contact action | Momentary |
| Resistance to wrenching | 237 daN operating head |
| 36 daN operating ring | |
| Number of cable entry holes | 3 3 holed entry for Pg 13.5 cable glands for Pg 13.5 |
| Mechanical life | 1500000 times |
| Rated operating current [Ie] | 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A |
| 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A | |
| Conventional enclosed heating current [Ithe] | 10A |
| Rated insulation voltage [Ui] | 400 V (pollution degree 3) conforming to EN/IEC 60947-1 |
| 300 V conforming to UL 508 | |
| 300 V conforming to CSA C22.2 No 14 | |
| model | XY2CD |
| environment | |
| certified product | CCC |
| CE | |
| operating temperature | -20…70°C |
| IP protection class | IP66 Compliant with screwed |
| packaging unit | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.200 cm |
| Package 1 Width | 6.500 cm |
| Package 1 Length | 14.600 cm |
| Package 1 Weight | 285.000g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.745 kg |
| contract warranty | |
| Warranty | 18 months |
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to EN/IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
| 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | |
| 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
| 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
| 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 | |
| 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | |
| Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
| 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
| 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
| 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
| 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
| Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 |
| Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | |
| Signalling type | Steady |
| Current consumption | 18 mA |
| Service life | 100000 h at rated voltage and 25 °C |
| Surge withstand | 1 kV conforming to IEC 61000-4-5 |
| Supply voltage limits | 19.2…30 V DC |
| 21.6…26.4 V AC | |
| Device presentation | Complete product |
| Environment | |
| Protective treatment | TH |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -40…70 °C |
| Electrical shock protection class | Class I conforming to IEC 60536 |
| IP degree of protection | IP66 conforming to IEC 60529 |
| IP67 | |
| IP69 | |
| IP69K | |
| NEMA degree of protection | NEMA 13 |
| NEMA 4X | |
| IK degree of protection | IK06 conforming to IEC 50102 |
| Standards | EN/IEC 60947-5-1 |
| JIS C8201-5-1 | |
| EN/IEC 60947-5-5 | |
| CSA C22.2 No 14 | |
| EN/IEC 60947-5-4 | |
| EN/IEC 60947-1 | |
| UL 508 | |
| JIS C8201-1 | |
| Product certifications | LROS (Lloyds register of shipping) |
| DNV | |
| BV | |
| GL | |
| UL listed | |
| CSA | |
| Vibration resistance | 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 |
| 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | |
| Resistance to fast transients | 2 kV conforming to IEC 61000-4-4 |
| Resistance to electromagnetic fields | 10 V/m conforming to IEC 61000-4-3 |
| Resistance to electrostatic discharge | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 |
| 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | |
| Electromagnetic emission | Class B conforming to IEC 55011 |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.500 cm |
| Package 1 Width | 5.500 cm |
| Package 1 Length | 8.500 cm |