Sale!

Festo 8074906 Pressure Sensor, 0–10 bar, IO-Link

Original price was: USD 194.74.Current price is: USD 167.70.

Piezoresistive relative-pressure sensing with two selectable PNP/NPN outputs, configurable analogue signals, an illuminated LCD and MS6 flange mounting.

SKU Festo-8074906 Category
Festo Pressure Sensors And Vacuum Sensors

Festo SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D Pressure Sensor

BrandFesto
Model IdentifierSPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D
Official Part Number8074906

Technical Overview

The Festo SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D measures relative pressure from 0 to 10 bar using a piezoresistive sensing element and mounts on a service unit through a flange connection. Two selectable PNP or NPN switching outputs and configurable 0–10 V, 1–5 V or 4–20 mA analogue signalling connect pressure conditions to machine controls. IO-Link V1.1 provides digital pressure data, parameter setting and diagnostics, while an illuminated LCD supports local readings and adjustment. The sensor operates from 20–30 V DC through a four-contact A-coded M12 connector, with IP65 protection and a 3 ms minimum IO-Link cycle time for pressure monitoring.

0–10 bar relative-pressure sensor with IO-Link V1.1, two switchable PNP/NPN outputs, configurable analogue output and MS6 flange mounting.

Key Features

  • Piezoresistive relative-pressure measurement from 0 to 10 bar
  • ±1.5% FS accuracy and ±0.3% FS repetition accuracy
  • Two PNP or two NPN switching outputs, selectable as NC or NO
  • Configurable analogue output: 0–10 V, 1–5 V or 4–20 mA
  • IO-Link V1.1, COM2 at 38.4 kBaud, class A port
  • 3 ms minimum IO-Link cycle time; 14-bit pressure process value
  • Illuminated LCD, teach-in and button-based adjustment
  • 20–30 V DC supply through a four-contact A-coded M12 connector
  • Service-unit flange mounting in any position
  • IP65 enclosure protection and CRC 2 corrosion resistance

Monitor service-unit pressure locally and through IO-Link while providing configurable switching and analogue signals to machine controls.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Listed (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
KC markKC-EMV
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 MPa; 0 bar; 0 psi
End value for pressure measuring range1 MPa; 10 bar; 145 psi
Overload pressure1.5 MPa; 15 bar; 217.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]; Inert gas
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C...50 °C
Ambient temperature0 °C...50 °C
Resolution ADC12 bit
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching output2 x PNP or 2 x NPN, switchable
Switching functionFreely programmable
Switching element functionNC or NO, switchable
Max. output current100 mA
Analogue output0 - 10 V; 4 - 20 mA; 1 - 5 V
Rise time3 ms
Max. load resistance current output500 Ohm
Min. load resistance voltage output10 kOhm
Short circuit current ratingYes
Overload protectionYes
ProtocolIO-Link®
IO-Link, Protocol versionDevice V 1.1
IO-Link, ProfileSmart sensor profile
IO-Link, Function classesBinary data channel (BDC); Process data variable (PDV); Identification; Diagnostics; Teach channel
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, Port classA
IO-Link, Process data length OUT0 bytes
IO-Link, Process data length IN2 bytes
IO-Link, Process data content IN14 bit PDV (pressure measurement value); 2 bit BDC (pressure monitoring)
IO-Link, Min. cycle time3 ms
IO-Link, Data storage required0.5 KB
Operational voltage range DC20 V...30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores4
Electrical connection 1, type of mountingNot rotatable
Electrical connection 1, compatible type of mountingCompatible with rotatable screw-type lock
Type of mountingOn service unit
Mounting positionAny
Pneumatic connectionFlange
Physical Weight (kg)0.08
Material in contact with the mediumFluoro rubber; Reinforced PA
Display typeIlluminated LCD
Displayable unitsMPa; bar; inH2O; inHg; kPa; kgf/cm²; mmHg; psi
Setting optionsIO-Link®; Teach-in; Via display and buttons
Protection against tamperingIO-Link®; PIN code
Setting range threshold value0 %...100 %
Setting range hysteresis0 %...90 %
Degree of protectionIP65
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L

Industrial Applications

1. Pneumatic Supply Readiness at Assembly Stations

An automated assembly station needs a usable air supply before it starts a pneumatic sequence. Mounted on the service unit, this sensor measures the incoming relative pressure and supplies programmable switching signals to the controller. Its illuminated LCD also lets maintenance staff see the same supply condition beside the machine during setup.

Problem Solved

Programmable pressure thresholds turn an inadequate supply condition into a controller input, supporting a start permissive based on measured pressure rather than a manual gauge reading.

0–10 bar 2 switching outputs Illuminated LCD

2. Pressure Trend Recording During Machine Cycles

A packaging machine can experience pressure dips when several pneumatic consumers operate together. The sensor sends a digital pressure value through IO-Link, allowing a control system to record supply trends alongside the machine sequence. Its 3 ms minimum communication cycle and two-byte input data provide a documented interface for collecting these measurements.

Problem Solved

Digital pressure values reveal supply behaviour during operation, helping maintenance correlate pressure reductions with machine events instead of relying only on occasional local readings.

IO-Link V1.1 3 ms minimum cycle 14-bit pressure value

3. Regulated-Air Adjustment with Analogue Feedback

During fixture changeover, a technician adjusts the regulated air supply for the next production task. The illuminated LCD provides a local pressure reading, while a selectable voltage or current output carries the measurement to an existing analogue input. This combination supports recording the adjusted pressure without requiring the controller to use IO-Link communication.

Problem Solved

Selectable analogue signalling connects measured pressure to established input hardware, while the local display gives the technician immediate feedback during regulated-air adjustment at the service unit.

4–20 mA 0–10 V / 1–5 V Local LCD
Select your currency