18 mm ISO sub-base valve with 24 V DC coil, mechanical spring reset, inductive PNP normal-position sensing and a 0.5 m M12 sensor connection.

SKU Festo-573201 Category
Festo Solenoid Valves

Festo VSVA-B-M52-MZD-A2-1T1L-APX-0.5 Monitored Solenoid Valve

BrandFesto
Model IdentifierVSVA-B-M52-MZD-A2-1T1L-APX-0.5
Official Part Number573201

Technical Overview

The Festo VSVA-B-M52-MZD-A2-1T1L-APX-0.5 is an 18 mm-wide 5/2-way single-solenoid valve with mechanical spring reset and inductive sensing of its normal position. The valve operates at 24 V DC through an ISO 15407-2 electrical connection, while the PNP sensor uses a separate 10–30 V DC range and a 0.5 m connection with four-pin M12 interface. Standard nominal flow is 550 l/min for the pneumatically interlinked arrangement. Internal or external pilot arrangements operate at 3–10 bar, with a −0.9 to 10 bar working range. Valve and sensor LEDs provide local indication, and IP65/NEMA 4 protection supports machine integration.

18 mm 5/2-way single-solenoid ISO valve with mechanical spring reset, inductive PNP normal-position sensor and 0.5 m M12 sensor connection.

Key Features

  • 5/2-way single-solenoid function with mechanical spring reset
  • Inductive sensor monitors the normal valve position
  • PNP sensor output with N/C contact switching function
  • 18 mm ISO 15407-2 sub-base interface
  • 24 V DC, 1.6 W valve coil with 100% duty cycle
  • 10–30 V DC sensor supply; 200 mA maximum sensor output current
  • 0.5 m sensor connection with four-pin M12x1 interface
  • 550 l/min standard nominal flow; valve-only flow 750 l/min
  • 12 ms valve switch-on and 38 ms switch-off times
  • IP65/NEMA 4 protection with valve and sensor LED indication

Combine ISO-format 5/2-way pneumatic switching with an inductive signal for the valve's normal position through a 0.5 m M12 sensor connection.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, single solenoid
Type of actuationElectrical
Construction width18 mm
Standard nominal flow rate (standardised to DIN 1343)550 l/min
pneumatic working portSub-base size 18 mm to ISO 15407-2; G1/8
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Type of resetMechanical spring
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
Degree of protectionIP65; NEMA 4
Nominal size5 mm
Exhaust-air functionCan be throttled; Via throttle plate; Via individual sub-base
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting; Concealed
Type of pilotingPiloted
Pilot air supplyExternal; Internal
Flow directionNon-reversible
Measuring principleInductive
lapOverlap
Reverse polarity protection sensorFor all electrical connections
Signal status displayLED
Switching position sensingNormal position with sensor
Switching status display sensorLED
Pilot pressure0.3 MPa...1 MPa; 3 bar...10 bar
Flow rate of valve750 l/min
Flow rate of valve on individual sub-base600 l/min
Valve flow rate, pneumatically linked, flow optimized700 l/min
Flow rate of pneumatically interlinked valve550 l/min
Switching time off38 ms
Switching time on12 ms
Valve - sensor switching time on32 ms
Valve - sensor switching time off9 ms
Duty cycle100%
Max. positive test pulse with 0 signal1500 µs
Max. negative test pulse with 1 signal800 µs
Nominal operating voltage DC24 V
Switching outputPNP
Characteristic coil data24 V DC: 1.6 W
Immunity to surge2.5 kV
Pollution degree3
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-5 °C...50 °C
Relative air humidity0 - 90%
Sound pressure level85 dB(A)
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting0.8 Nm...1.2 Nm
Physical Weight (kg)0.157
Operating voltage range, DC sensor10 V...30 V
Short-circuit strength sensorPulsed
Idle current sensor10 mA
Max. output current sensor200 mA
Max. switching frequency sensor5000 Hz
Residual ripple sensor±10%
Voltage drop sensor2 V
Electrical connection4-pin; Plug; To ISO 15407-2
Sensor connectionPlug; Cable; 4-pin; M12x1; 0.5 m
Type of mountingOn sub-base
Pilot air port 12/14Sub-base size 18 mm to ISO 15407-2
Pilot exhaust port 82/84Ducted; Not ducted; Either:
Pneumatic connection, port 1Sub-base size 18 mm to ISO 15407-2
Pneumatic connection, port 2Sub-base size 18 mm to ISO 15407-2
Pneumatic connection, port 3Sub-base size 18 mm to ISO 15407-2
Pneumatic connection, port 4Sub-base size 18 mm to ISO 15407-2
Pneumatic connection, port 5Sub-base size 18 mm to ISO 15407-2
Note on materialsRoHS compliant
Material sealsFluoro rubber; NBR
Material housingDie-cast aluminium; PA
Material screwsGalvanised steel
Switching element functionN/C contact

Industrial Applications

1. Normal-Position Feedback in a Cylinder Sequence

An assembly controller needs a valve-position input in addition to the electrical command used to operate a double-acting cylinder. The 5/2-way valve provides directional switching and mechanical spring reset, while its inductive sensor reports the normal valve position. The PNP output connects that condition to an appropriate control input rather than treating coil de-energization alone as position feedback.

Problem Solved

Independent normal-position sensing provides a measured valve condition alongside the command signal, supporting sequence diagnostics without assuming that an electrical output alone describes the valve's position.

Normal-position sensing PNP output Mechanical spring reset

2. Gripper Control with Separate Pilot-Air Arrangement

A handling unit operates a double-acting gripper from a working circuit whose pressure is arranged separately from valve piloting. This model supports external pilot air at 3–10 bar and a working range extending down to −0.9 bar. Its single-solenoid 5/2-way function provides directional control, while the normal-position sensor adds a feedback condition for the machine sequence.

Problem Solved

A separate pilot arrangement permits independent actuation pressure, while normal-position feedback adds information about the directional valve to the gripper sequence beyond its electrical command.

External pilot arrangement 3–10 bar pilot 5/2-way

3. Commissioning of Valve Commands and Feedback Wiring

During valve-station commissioning, a technician needs to relate the output command, local indication and controller feedback to the same valve. This model provides valve signal LEDs, a sensor switching LED and an M12 sensor connection with 0.5 m cable. These interfaces let the technician observe the command indication and normal-position feedback while testing the configured pneumatic sequence.

Problem Solved

Separate local indication and sensor feedback make command and position information observable during commissioning, helping locate a mismatch between the intended sequence and connected feedback input.

Valve LED Sensor LED 0.5 m M12 connection