1. Fibre-Optic Position Sensing at a Tooling Point
An assembly fixture needs an optical position event at a tooling point where the sensing arrangement is implemented with fibre optics. The unit supplies red-light optoelectronic sensing and a PNP output for the machine input. Teach-in supports establishing the sensing condition, while the 2 m four-core cable connects the electronics to the control wiring away from the optical interface.
Problem Solved
The fibre-optic unit converts the configured optical sensing condition into a PNP control signal, giving the machine a position event without placing a complete electrical sensor body at the optical point.
Fibre-optic sensing
Red light
PNP output
2. Optical Event Timing for a Machine Sequence
A packaging station needs optical event signals arranged for its electrical sequence timing. The unit combines a maximum 1500 Hz switching frequency with a documented 1–2000 ms timer function and a switchable output function. These capabilities give the integrator sensing and timing parameters to coordinate with the controller, while electrical teach-in permits adjustment through the installed wiring.
Problem Solved
Integrated sensing and timer functions provide configurable event handling at the sensor unit, supporting coordination of optical switching with the machine's input and sequence requirements.
1500 Hz maximum
1–2000 ms timer
Electrical teach-in
3. Grouped Optical Sensing Electronics on a DIN Rail
A machine cabinet groups several fibre-optic sensing channels close together to serve adjacent process points. The manufacturer permits up to four units mounted directly next to one another with mutual-influence protection. DIN-rail mounting organizes the electronics, and separate switching and function-reserve LEDs give local information for commissioning each configured sensing channel.
Problem Solved
Documented adjacent-unit interference protection supports a compact group of optical sensing electronics, while individual LEDs make each channel's switching and function-reserve conditions visible during setup.
Up to 4 adjacent units
DIN rail
Function-reserve LED