Sale!

Festo 542025 Precision Flow Control Valve, G1/8, Scaled Knob

Original price was: USD 135.20.Current price is: USD 116.74.

Manual valve for unlubricated compressed air or inert gas, with 75.8 l/min nominal controlled flow, aluminium sub-base and 110 g weight.

SKU Festo-542025 Category
Festo Flow Control Valves

Festo GRPO-160-1/8-AL Precision Flow Control Valve

BrandFesto
Model IdentifierGRPO-160-1/8-AL
Official Part Number542025

Technical Overview

The Festo GRPO-160-1/8-AL is a manually adjusted precision flow control valve with G1/8 connections and a rotary knob with scale. Its standard nominal controlled-direction flow is 75.8 l/min, with separate ratings of 38 l/min at 1-to-0 bar and 129 l/min at 6-to-0 bar. The general operating range is 0–8 bar, but flow from port 2 to port 1 is restricted to 0–0.5 bar. Suitable media are unlubricated compressed air to ISO 8573-1 [5:4:3] and inert gas. The 110 g assembly uses a reinforced PA housing and wrought aluminium sub-base, with any-position mounting and a −10 to +50 °C ambient range.

Manual G1/8 precision flow control valve with scaled rotary knob, 75.8 l/min nominal controlled flow and compatibility with unlubricated air or inert gas.

Key Features

  • Flow control function with manual actuation
  • Rotary adjustment knob with scale
  • G1/8 connections at ports 1 and 2
  • 75.8 l/min standard nominal flow in the controlled direction
  • 38 l/min throttled flow at 1-to-0 bar; 129 l/min at 6-to-0 bar
  • 0–8 bar general operating range
  • Port 2-to-1 pressure range limited to 0–0.5 bar
  • Unlubricated ISO 8573-1 [5:4:3] compressed air or inert gas
  • 110 g product weight with reinforced PA housing and aluminium sub-base
  • Any mounting position with −10 to +50 °C ambient and media range

Set unlubricated air or inert-gas flow through G1/8 connections using a scaled rotary adjustment with documented pressure-specific flow ratings.

Technical Specification Matrix

ParameterValue
Valve functionFlow control function
Pneumatic connection, port 1G1/8
Pneumatic connection, port 2G1/8
Type of actuationManual
Adjustment componentRotary knob with scale
Type of mountingOn sub-base
Standard nominal flow rate in flow control direction75.8 l/min
Operating pressure0 bar...8 bar
Ambient temperature-10 °C...50 °C
Material housingReinforced PA
Mounting positionAny
Operating pressure from 2 to 10 bar...0.5 bar
Standard nominal flow rate in throttle direction for 0.1->0 MPa (1->038 l/min
Standard flow rate in flow control direction 0.6->0 MPa (6->0 bar, 87->0129 l/min
Operating mediumCompressed air to ISO 8573-1:2010 [5:4:3]; Inert gas
Note on operating and pilot mediumLubricated operation not possible
LABS (PWIS) conformityVDMA24364 zone III
Media temperature-10 °C...50 °C
Physical Weight (kg)0.11
Note on materialsRoHS compliant
Material sub-baseWrought aluminium alloy
Material sealsNBR; PVC
Material screwsSteel

Industrial Applications

1. Inert-Gas Purge Adjustment

A process enclosure needs a manually set inert-gas purge through a suitable pneumatic line. The GRPO explicitly permits inert gas and provides a scaled rotary knob for adjusting restriction. G1/8 connections and the published controlled-direction flow ratings characterize the selected valve, while its −10 to +50 °C media range defines the documented thermal condition for the gas passing through it.

Problem Solved

Manual restriction provides a local means of setting the purge flow path, with a scaled adjustment reference and manufacturer-documented compatibility with inert gas as the operating medium.

Inert gas Scaled rotary knob G1/8 ports

2. Adjustable Air Supply for a Pneumatic Test Fixture

A test fixture needs to vary the restriction in an unlubricated compressed-air branch between test setups. This manual valve provides a rotary scale as a reference for the selected setting, with 75.8 l/min standard nominal controlled flow and a separate 38 l/min rating at 1-to-0 bar. The published ratings characterize the valve; the scale does not independently measure actual branch flow.

Problem Solved

The scaled manual adjustment gives the test fixture a defined local restriction setting reference, while pressure-specific flow ratings support evaluation of the selected pneumatic branch.

75.8 l/min nominal 38 l/min at 1-to-0 bar Unlubricated air

3. Metering a Low-Pressure Reverse-Flow Branch

A pneumatic circuit needs manual flow restriction in a branch whose routing passes from port 2 toward port 1. Festo specifies a distinct 0–0.5 bar operating range for that direction, rather than the general 0–8 bar rating. The G1/8 interfaces and any-position mounting support the physical arrangement, while the directional pressure limit defines the supported reverse-flow condition of this exact valve.

Problem Solved

The documented reverse-direction range provides a supported basis for low-pressure branch metering, keeping the actual flow direction tied to its own pressure limit during circuit design.

Port 2 → port 1 0–0.5 bar Manual metering
Select your currency