1. Transfer Cylinder with a Vented Neutral Circuit State
A machine moves a suitable double-acting cylinder in two directions and requires a valve neutral state that connects the working circuit to exhaust. The 5/3 exhausted-centre function supplies those three routing states, while mechanical spring reset returns the valve to its centre. The 200 l/min nominal flow and flange interface characterize the selected valve within its manifold arrangement.
Problem Solved
The exhausted centre supplies a distinct vented routing state between directional commands, supporting a cylinder circuit that requires working-line exhaust rather than closed valve paths in neutral.
5/3 exhausted centre
200 l/min
Spring reset
2. Gripper Control with Separate Pilot Pressure
A handling machine uses a suitable double-acting gripper circuit whose working pressure differs from the valve actuation supply. External pilot air at 3–8 bar operates this valve independently of its −0.9 to 10 bar working range. The two directional states command the gripper circuit, and the exhausted centre provides a third routing state when working-line exhaust is required by the mechanism's pneumatic sequence.
Problem Solved
Separate pilot air supports valve actuation at a defined positive pressure while the gripper working circuit uses its own pressure condition and the specified three-state routing function.
External pilot
3–8 bar pilot
Exhausted neutral
3. Reversible Pneumatic Motor Routing
A machine uses a suitable reversible pneumatic motor and needs forward, reverse and vented neutral air-routing commands. This valve supplies a 5/3 exhausted-centre function through its flange interface, with an E-box electrical connection for the commands. The specified 16 ms reversal time and 3 Hz maximum switching frequency characterize the valve component; the motor's mechanical run-down remains a property of the complete drive and load.
Problem Solved
One electrically commanded valve provides forward, reverse and vented neutral routing states, with documented timing limits for evaluating its place in the pneumatic motor command sequence.
Forward/reverse/vented neutral
16 ms reversal
3 Hz maximum