Sale!

Festo 534540 Solenoid Valve, 5/3 Exhausted, ISO 26 mm, 24 V DC

Original price was: USD 151.06.Current price is: USD 130.26.

Internally piloted valve with 1000 l/min nominal flow, four-pin M8 central plug, holding-current reduction, spring reset and IP65/NEMA 4 protection.

SKU Festo-534540 Category
Festo Solenoid Valves

Festo VSVA-B-P53E-H-A1-1R2L Solenoid Valve

BrandFesto
Model IdentifierVSVA-B-P53E-H-A1-1R2L
Official Part Number534540

Technical Overview

The Festo VSVA-B-P53E-H-A1-1R2L is a 26 mm-wide 5/3-way solenoid valve with an exhausted centre and mechanical spring reset. Its ISO 15407-1 sub-base interface provides 1000 l/min standard nominal flow for an interlinked arrangement, with 1400 l/min valve-only and 1100 l/min individual-sub-base ratings stated separately. Internal piloting requires a 3–8 bar working range, and flow is non-reversible. The 24 V DC valve uses a four-pin M8 central plug with holding-current reduction from 110 mA pickup to 30 mA after 20 ms per coil. The 270 g unit has IP65/NEMA 4 protection, LED indication and 20 ms on/52 ms off switching times.

26 mm ISO 15407-1 5/3-way exhausted-centre valve with internal piloting, 1000 l/min nominal flow and four-pin M8 electrical connection.

Key Features

  • 5/3-way exhausted-centre function with mechanical spring reset
  • 26 mm construction width and ISO 15407-1 sub-base interface
  • 1000 l/min standard nominal interlinked flow
  • 1400 l/min valve-only and 1100 l/min individual-sub-base flow
  • Internal pilot supply and 3–8 bar operating pressure
  • 24 V DC operation via four-pin M8 central plug
  • Holding-current reduction: 110 mA pickup, 30 mA after 20 ms per coil
  • 20 ms switch-on and 52 ms switch-off times; 100% duty cycle
  • LED indication, non-detenting manual override and reverse-polarity protection
  • 270 g product weight with IP65/NEMA 4 protection

Provide two directional commands and an exhausted-centre state on a 26 mm ISO sub-base, with 1000 l/min nominal flow and holding-current reduction.

Technical Specification Matrix

ParameterValue
Valve function5/3 exhausted
Type of actuationElectrical
Construction width26 mm
Standard nominal flow rate (standardised to DIN 1343)1000 l/min
pneumatic working portSub-base size 26 mm to ISO 15407-1
Operating voltage24 V DC
Operating pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
DesignPiston gate valve
Type of resetMechanical spring
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Degree of protectionIP65; NEMA 4
Nominal size9 mm
Mounting grid pitch27 mm
Exhaust-air functionCan be throttled; Via throttle plate; Via individual sub-base
Sealing principleSoft
Mounting positionAny
Conforms to standardISO 15407-1
Manual overrideNon-detenting
Type of pilotingPiloted
Pilot air supplyInternal
Flow directionNon-reversible
lapOverlap
Reverse polarity protectionFor all electrical connections
Additional functionsHolding current reduction; Safety shut-off
Signal status displayLED
b value0.3
C value2.9 l/sbar
Flow rate of valve1400 l/min
Flow rate of valve on individual sub-base1100 l/min
Flow rate of pneumatically interlinked valve1000 l/min
Switching time off52 ms
Switching time on20 ms
Duty cycle100%
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal100 µs
Nominal pick-up current per solenoid coil110 mA to 20 ms
Nominal current with current reduction30 mA after 20 ms
Characteristic coil data24 V DC: low-current phase 1.0 W, high-current phase 2.4 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-5 °C...50 °C
Relative air humidity0 - 90%
Protection against direct and indirect contactPELV
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting1.8 Nm...2.2 Nm
Physical Weight (kg)0.27
Electrical connection4-pin; M8x1; Central plug; Round design
Type of mountingOn sub-base; Via through-hole and screw
Note on materialsRoHS compliant
Material sealsFluoro rubber; HNBR; NBR
Material housingDie-cast aluminium

Industrial Applications

1. Transfer Cylinder with a Vented Neutral Circuit State

A machine moves a suitable double-acting cylinder in two directions and requires a valve neutral state that connects the working circuit to exhaust. The 5/3 exhausted-centre function supplies those three routing states, with mechanical spring reset to centre. Its ISO 15407-1 sub-base interface and 1000 l/min interlinked nominal flow characterize the valve within the documented 26 mm station arrangement.

Problem Solved

The exhausted centre supplies a distinct vented routing state between directional commands, supporting a cylinder circuit that requires working-line exhaust rather than closed valve paths in neutral.

5/3 exhausted centre ISO 15407-1 1000 l/min

2. Gripper Circuit with a Vented Neutral State

A handling machine needs open, close and vented neutral valve commands for a suitable double-acting pneumatic gripper circuit. The exhausted-centre function provides the third routing state, while internal piloting operates within the 3–8 bar working range. A four-pin M8 central plug supplies electrical commands, and holding-current reduction characterizes the coil drive when a working command remains applied.

Problem Solved

Three directional routing states support the gripper sequence, while the central electrical connection and holding-current reduction define the valve interface for maintaining a commanded working state.

Vented neutral Internal pilot Holding-current reduction

3. Reversible Pneumatic Motor Routing

A machine uses a suitable reversible pneumatic motor and needs forward, reverse and vented neutral routing commands. This valve supplies those states through its ISO 15407-1 interface, with a four-pin M8 central electrical plug. Specified 20 ms on and 52 ms off times characterize the valve component, while motor run-down and stopping behavior remain properties of the complete drive and load.

Problem Solved

One electrically commanded valve provides forward, reverse and vented neutral air routing, with documented component switching times for evaluating its place in the pneumatic motor command sequence.

Forward/reverse/vented neutral 20 ms on 52 ms off
Select your currency