Sale!

Festo 530502 Microfilter, G1/2, 0.01 µm, Automatic Drain

Original price was: USD 104.52.Current price is: USD 90.48.

MS6 fibre filter with ISO 8573-1 [3:4:2] output class, 135–900 l/min rated clean-air flow, 0.01 mg/m³ residual oil and 2–12 bar operation.

SKU Festo-530502 Category
Festo Compressed Air Filters

Festo MS6-LFM-1/2-ARV Microfilter

BrandFesto
Model IdentifierMS6-LFM-1/2-ARV
Official Part Number530502

Technical Overview

The Festo MS6-LFM-1/2-ARV is an MS size 6 microfilter with a 0.01 µm filtration grade and G1/2 inlet and outlet connections. Its borosilicate fibre element is specified for compressed air or inert gas, with ISO 8573-1 [3:4:2] output air purity and a 135–900 l/min standard-flow range for that clean-air class. The manufacturer lists 0.01 mg/m³ residual oil content and 99% oil-aerosol efficiency separately from the fine-particle and MPPS ratings. Fully automatic and non-detenting manual condensate-drain functions serve a 38 cm³ maximum condensate volume. The 600 g assembly uses a die-cast aluminium housing, Makrolon bowl and plastic bowl guard, with 2–12 bar operation.

G1/2 MS6 microfilter with 0.01 µm filtration grade, ISO [3:4:2] output purity, 135–900 l/min rated clean-air flow and automatic condensate drainage.

Key Features

  • MS series size 6 fibre-filter design
  • 0.01 µm filtration grade with borosilicate fibre element
  • G1/2 connections at inlet and outlet
  • ISO 8573-1 [3:4:2] output air-purity class
  • 135–900 l/min standard-flow range for the specified clean-air class
  • 0.01 mg/m³ residual oil content and 99% oil-aerosol efficiency
  • Fully automatic and non-detenting manual condensate drainage
  • 38 cm³ maximum condensate volume with plastic bowl guard
  • 2–12 bar operation and vertical mounting within ±5°
  • 600 g product weight and −10 to +60 °C ambient/media range

Prepare a G1/2 compressed-air branch to the specified ISO [3:4:2] output class using a 0.01 µm fibre filter with automatic condensate drainage.

Technical Specification Matrix

ParameterValue
SeriesMS
Size6
DesignFibre filter
Grade of filtration0.01 µm
Condensate drainFully automatic; Manual, non-detenting
Operating pressure0.2 MPa...1.2 MPa; 2 bar...12 bar
Operating mediumCompressed air to ISO 8573-1:2010 [6:4:4]; Inert gas
Air purity class at outputCompressed air to ISO 8573-1:2010 [3:4:2]
Max. standard flow rate for clean air class900 l/min
Min. standard flow rate for clean air class135 l/min
Filter efficiency99.9999 %
Max. condensate volume38 cm³
Bowl guardPlastic bowl guard
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Suitable for use with foodSee supplementary material information
Media temperature-10 °C...60 °C
Ambient temperature-10 °C...60 °C
Storage temperature-10 °C...60 °C
Filter efficiency, fine particles99.995 %
MPPS0.05 µm
Filter efficiency MPPS99.95 %
Residual oil content0.01 mg/m³
Filter efficiency, oil aerosol99 %
Type of mountingEither:; Inline installation; With accessories
Mounting positionVertical +/-5°
Pneumatic connection, port 1G1/2
Pneumatic connection, port 2G1/2
Material housingDie-cast aluminium
Material filterBorosilicate fibre
Material bowlMakrolon®
Material sealsNBR
Note on materialsRoHS compliant
Physical Weight (kg)0.6

Industrial Applications

1. Fine-Particle Filtration for a Machine Air Branch

A machine air branch requires a documented filtration stage before supplying downstream pneumatic equipment. This microfilter uses a borosilicate fibre element with a 0.01 µm grade and an ISO 8573-1 [3:4:2] output class under its stated conditions. The 135–900 l/min clean-air-class flow range and G1/2 connections characterize the selected filter's capacity and interface for that branch.

Problem Solved

The specified fibre filtration stage provides a manufacturer-defined air-purity characteristic for the branch, with its clean-air flow limits kept attached to the output-class requirement.

0.01 µm grade ISO [3:4:2] output G1/2 ports

2. Oil-Aerosol Reduction Ahead of a Process Air Line

A process air line needs a filter with explicit oil-aerosol characteristics rather than only a nominal particle grade. Festo specifies 0.01 mg/m³ residual oil content and 99% oil-aerosol efficiency for this exact unit. Its 2–12 bar operating range and −10 to +60 °C media range define additional conditions for the filter stage, without treating its particle and oil ratings as interchangeable claims.

Problem Solved

Separate residual-oil and oil-aerosol ratings characterize the filtration stage for an oil-sensitive air branch, providing relevant manufacturer data beyond the particle filtration grade alone.

0.01 mg/m³ residual oil 99% oil-aerosol efficiency 2–12 bar

3. Condensate Management in a Local Air-Preparation Station

A local air-preparation station needs collected condensate to leave the filter bowl during normal operation. The ARV configuration includes fully automatic drainage and a non-detenting manual function, with 38 cm³ maximum condensate volume. Vertical installation within ±5° is the documented mounting requirement, while the plastic guard surrounds the Makrolon bowl in the 600 g filter assembly.

Problem Solved

Automatic condensate drainage provides a defined outlet function for collected liquid, reducing dependence on manual bowl draining during normal operation while retaining the specified installation orientation.

Automatic drain 38 cm³ condensate volume Vertical ±5°
Select your currency