Sale!

Festo 527460 Vacuum Pressure Sensor, 0 to −1 bar, PNP NO

Original price was: USD 93.08.Current price is: USD 80.60.

Piezoresistive threshold sensor with teach-in, QS-4 connection, three-pin M8 plug, ±0.5% FS accuracy and 2 ms switching times on a 15–30 V DC supply.

SKU Festo-527460 Category
Festo Pressure Sensors And Vacuum Sensors

Festo SDE5-V1-O-Q4E-P-M8 Vacuum Pressure Sensor

BrandFesto
Model IdentifierSDE5-V1-O-Q4E-P-M8
Official Part Number527460

Technical Overview

The Festo SDE5-V1-O-Q4E-P-M8 measures relative pressure from 0 to −1 bar using a piezoresistive sensing element. Its PNP normally open output implements a teach-in threshold with fixed 2% FS hysteresis and specified 2 ms switch-on and switch-off times. Accuracy is ±0.5% FS, with ±0.3% FS repetition accuracy under the manufacturer's conditions. A QS-4 pneumatic connection links the sensing line, while a three-pin A-coded M8 plug supplies 15–30 V DC power and the switching output. The 19 g sensor has a yellow switching LED, IP40 protection and Class 4 cleanroom suitability, with 0 to +50 °C ambient and media operation.

0 to −1 bar relative-pressure sensor with PNP normally open threshold output, teach-in, QS-4 pneumatic connection and three-pin M8 plug.

Key Features

  • Piezoresistive measurement of relative pressure from 0 to −1 bar
  • PNP normally open switching output
  • Threshold function with fixed 2% FS hysteresis
  • Teach-in adjustment across 0–100% threshold setting range
  • ±0.5% FS accuracy and ±0.3% FS repetition accuracy
  • 2 ms switch-on and 2 ms switch-off times
  • QS-4 pneumatic connection and three-pin A-coded M8 plug
  • 15–30 V DC supply and 100 mA maximum output current
  • 19 g product weight with yellow switching LED
  • IP40 protection, Class 4 cleanroom suitability and 0 to +50 °C ambient/media range

Provide a taught vacuum-threshold signal through a PNP output with 2 ms switching times and a direct QS-4 sensing-line connection.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 MPa; 0 bar; 0 psi
End value for pressure measuring range-0.1 MPa; -1 bar; -14.5 psi
Overload pressure0.5 MPa; 5 bar; 72.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C...50 °C
Ambient temperature0 °C...50 °C
Accuracy in ± % FS0.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching outputPNP
Switching functionThreshold value with fixed hysteresis
Switching element functionN/O contact
Hysteresis in ± %FS2 %FS
Switch-on time2 ms
Switch-off time2 ms
Max. output current100 mA
Voltage drop1.8 V
Short circuit current ratingYes
Overload protectionYes
Operational voltage range DC15 V...30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM8x1, A-coded, to EN 61076-2-104
Electrical connection 1, number of connections/cores3
Electrical connection 1, type of mountingSnap-locking; Screw-type lock; Not rotatable
Electrical connection 1, compatible type of mountingCompatible with latching lock; Compatible with rotatable screw-type lock
Material connector housingBrass, nickel-plated
Max. cable length30 M
Type of mountingWith accessories
Mounting positionAny
Pneumatic connectionQS-4
Physical Weight (kg)0.019
Material housingReinforced PA; Reinforced POM
Material sealing ringFluoro rubber; NBR
Switching status indicationYellow LED
Setting optionsTeach-in
Setting range threshold value0 %...100 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1

Industrial Applications

1. Vacuum Pickup Confirmation Before Transfer

A vacuum-handling station needs a pressure-based signal before proceeding with a transfer command. The sensor measures the local vacuum line through QS-4 and changes its PNP threshold output at the taught setting within the 0 to −1 bar range. The fixed hysteresis and 2 ms component switching times characterize the signal behavior, while cup sealing and load security remain properties of the complete handling system.

Problem Solved

The taught threshold converts local vacuum pressure into a discrete controller signal, supporting a pickup-confirmation step before the handling sequence advances to the transfer command.

0 to −1 bar PNP threshold QS-4

2. Monitoring Vacuum Decay During a Release Sequence

After a vacuum tool receives a release command, the controller needs to observe whether the sensing-line vacuum crosses the selected threshold toward atmospheric pressure. This relative-pressure sensor provides that discrete switching result over its 0 to −1 bar range. Its 2 ms switch-off time characterizes the sensor component, rather than establishing when the workpiece has mechanically separated from the suction cup.

Problem Solved

Threshold switching supplies pressure-state feedback during the release sequence, helping the controller distinguish a vacuum line that remains beyond the setting from one that has crossed it.

Relative vacuum pressure 2 ms switch-off Threshold feedback

3. Vacuum Branch Loss Indication

A machine needs a discrete indication when a monitored vacuum branch no longer remains on the expected side of a pressure threshold during a commanded hold period. The SDE5 supplies a PNP normally open output, fixed hysteresis and a local yellow switching LED. The controller can use that signal as a pressure-state input for its branch-monitoring logic without treating the sensor as a quantitative leak-rate instrument.

Problem Solved

A local threshold signal makes a changed vacuum condition available to the control system, while the LED provides visible switching information for investigation of the affected branch.

PNP normally open Fixed hysteresis Yellow LED
Select your currency