Sale!

Festo 8099359 Pressure Regulator, G1/4, 0.3–7 bar, MPa Gauge

Original price was: USD 252.72.Current price is: USD 217.36.

MS4 piston regulator with 1800 l/min nominal flow, secondary exhausting, return-flow function, detent knob, 1–10 bar inlet range and 165 g weight.

SKU Festo-8099359 Category
Festo Pressure Regulator

Festo MS4-LR-1/4-D6-AG-MPA-B Pressure Regulator

BrandFesto
Model IdentifierMS4-LR-1/4-D6-AG-MPA-B
Official Part Number8099359

Technical Overview

The Festo MS4-LR-1/4-D6-AG-MPA-B is an MS size 4 pressure regulator with an included MPa pressure gauge and G1/4 connections. Its directly actuated piston mechanism provides a constant-output-pressure function over a 0.3–7 bar regulation range, with secondary exhausting and return flow. The specified operating supply range is 1–10 bar, and standard nominal flow is 1800 l/min. A detented rotary knob sets the regulator, with front-panel, inline or accessory mounting available. The 165 g assembly uses a reinforced PA housing, POM knob and NBR seals, and has documented Class 7 cleanroom suitability within a −5 to +50 °C ambient and media range.

G1/4 MS4 pressure regulator with 0.3–7 bar adjustment, MPa gauge, secondary exhausting, return flow and 1800 l/min nominal flow.

Key Features

  • MS series size 4 directly actuated piston regulator
  • 0.3–7 bar pressure-regulation range
  • 1–10 bar specified operating supply range
  • 1800 l/min standard nominal flow to DIN 1343
  • Constant output pressure with secondary exhausting
  • Integrated return-flow function
  • Included pressure gauge with MPa display units
  • G1/4 inlet/outlet ports and rotary knob with detent
  • 165 g product weight with reinforced PA housing and NBR seals
  • Front-panel/inline mounting and Class 7 cleanroom suitability

Set a G1/4 branch pressure from 0.3 to 7 bar with a local MPa gauge, secondary exhausting and return-flow capability.

Technical Specification Matrix

ParameterValue
Size4
SeriesMS
Actuator lockRotary knob with detent
Mounting positionAny
DesignPressure regulator with pressure gauge; Directly actuated piston regulator
Controller functionOutput pressure constant; With secondary exhausting; With return flow function
Displayable unitsMPa
Pressure gauge (ANALOG) or Pressure display (DIGITAL)With pressure gauge
Operating pressure0.1 MPa...1 MPa; 1 bar...10 bar
Pressure regulation range0.3 bar...7 bar
Max. pressure hysteresis0.05 MPa; 0.5 bar; 7.25 psi
Standard nominal flow rate (standardised to DIN 1343)1800 l/min
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]; Inert gas
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 7 according to ISO 14644-1
Storage temperature-5 °C...50 °C
Media temperature-5 °C...50 °C
Ambient temperature-5 °C...50 °C
Physical Weight (kg)0.165
Type of mountingEither:; Front panel mounting; Inline installation; With accessories
Pneumatic connection, port 1G1/4
Pneumatic connection, port 2G1/4
Note on materialsRoHS compliant
Material underneath coverPA
Material sealsNBR
Material rotary knobPOM
Material springHigh-alloy steel; Galvanised steel
Material housingReinforced PA
Material valve stemPOM

Industrial Applications

1. Reduced Working Pressure for a Pneumatic Fixture

A machine supplies a fixture branch from a main air line and needs a locally selected working pressure. This regulator provides 0.3–7 bar adjustment with a constant-output-pressure function, G1/4 connections and 1800 l/min nominal flow. The detented knob sets the local pressure, while the included MPa gauge gives the operator a direct indication at the regulator assembly.

Problem Solved

Local pressure regulation gives the fixture branch its selected pneumatic operating condition, with the knob and gauge combining adjustment and pressure observation at the same component.

0.3–7 bar regulation MPa gauge G1/4 ports

2. Downstream Pressure Reduction During Changeover

A fixture changeover requires lowering the downstream set pressure from the previous product setting. The MS4-LR includes secondary exhausting as part of its controller function, providing a relief path at the regulated side during pressure adjustment. The detented rotary knob and local pressure gauge support the setup operation within the 0.3–7 bar range, rather than relying only on downstream air consumption to reduce pressure.

Problem Solved

Secondary exhausting supports pressure reduction at the regulated branch during adjustment, while the local gauge displays the pressure condition as the operator changes the setting.

Secondary exhausting Detent knob Local gauge

3. Regulated Branch Requiring a Return-Flow Path

A pneumatic circuit includes a regulated branch whose pressure can exceed the upstream pressure during a supply change or exhaust sequence. The manufacturer lists a return-flow function for this exact regulator, providing the relevant reverse-flow capability in the pressure-control assembly. Its G1/4 ports and inline mounting support integrating that function into the branch, while the complete circuit determines the actual pressure decay and exhaust route.

Problem Solved

The documented return-flow function supports a reverse path through the regulator when the circuit pressure relationship drives return flow, keeping that behavior within the selected regulation assembly.

Return-flow function Inline mounting G1/4
Select your currency