Festo 556839 Dual 3/2 Normally Open Valve, 10 mm, 24 V DC

Original price was: USD 107.64.Current price is: USD 93.08.

Two normally open monostable functions with mechanical spring reset, 300 l/min nominal flow, reversible flow, vacuum suitability and IP65 protection.

SKU Festo-556839 Category
Festo Solenoid Valves

Festo VMPA1-M1H-NS-PI Dual Normally Open Solenoid Valve

BrandFesto
Model IdentifierVMPA1-M1H-NS-PI
Official Part Number556839

Technical Overview

The Festo VMPA1-M1H-NS-PI combines two normally open, monostable 3/2-way functions in a 10 mm solenoid valve with mechanical spring reset. It operates at 24 V DC across a −0.9 to 8 bar working range, with reversible flow and documented vacuum suitability. Standard nominal flow is 300 l/min, and the exact datasheet also states 300 l/min for a QS-6 arrangement. Pilot pressure is 3–8 bar, with 14 ms switch-on and 16 ms switch-off times. The 56 g die-cast aluminium valve has NBR seals, IP65 protection, signal indication and manual override, with through-hole mounting and a 0.25 Nm maximum valve-mounting torque.

10 mm dual normally open 3/2-way solenoid valve with 24 V DC actuation, mechanical spring reset, reversible flow and vacuum suitability.

Key Features

  • Two normally open, monostable 3/2-way functions
  • 10 mm valve size with mechanical spring reset
  • 24 V DC operation; permissible voltage variation ±25%
  • −0.9 to 8 bar working pressure; 3–8 bar pilot pressure
  • Reversible flow direction and documented vacuum suitability
  • 300 l/min standard nominal flow, also specified with QS-6 arrangement
  • 14 ms switch-on and 16 ms switch-off times
  • Detenting/non-detenting manual override and signal-status indication
  • IP65 protection; 56 g product weight
  • Through-hole mounting; 0.25 Nm maximum valve-mounting torque

Provide two normally open 3/2-way pneumatic functions with reversible flow and vacuum suitability in a 10 mm MPA valve.

Technical Specification Matrix

ParameterValue
Valve function2x3/2 open monostable
Type of actuationElectrical
Valve size10 mm
Standard nominal flow rate (standardised to DIN 1343)300 l/min
Operating voltage24 V DC
Operating pressure-0.09 MPa...0.8 MPa; -0.9 bar...8 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; To IEC 60529
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Flow directionReversible
lapOverlap
Signal status displayYes
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Suitability for vacuumYes
Standard nominal flow rate with QS-6300 l/min
Switching time off16 ms
Switching time on14 ms
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal200 µs
Permissible voltage fluctuations+/-25%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...40 °C
Media temperature-5 °C...50 °C
Relative air humidityMax. 90% at 40 °C
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting0.25 Nm
Physical Weight (kg)0.056
Type of mountingWith through-hole
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Normally Open Air-Purge Circuit Control

A machine circuit needs two air-purge lines whose specified normal valve state is open, with electrical commands changing the respective switching states. The dual normally open 3/2-way functions provide that arrangement in one 10 mm body. Mechanical spring reset returns the valve functions to their normal states, while the surrounding pneumatic circuit determines how each purge line is supplied and exhausted.

Problem Solved

Two normally open functions support purge circuits designed around an open normal state, consolidating their electrical switching and spring return in a single compact valve body.

2 × 3/2-way NO Mechanical spring reset 10 mm

2. Normally Open Vacuum-Line Switching

A vacuum-handling circuit needs an electrically switched path with a normally open valve state. This model is explicitly suitable for vacuum, with a working-pressure limit of −0.9 bar and reversible flow direction. Its separate 3–8 bar pilot-pressure requirement defines the positive-pressure actuation conditions while the working circuit handles vacuum, supporting the chosen vacuum and venting arrangement.

Problem Solved

Documented vacuum suitability and a normally open switching function provide a defined vacuum-circuit valve state, while the pilot-pressure specification separates actuation requirements from sub-atmospheric working pressure.

Vacuum suitability −0.9 bar Reversible flow

3. Compact Dual-Function Valve-Station Integration

A machine builder selects two normally open pneumatic functions at one compact valve position. This 10 mm unit supports through-hole mounting, with a maximum valve-mounting torque of 0.25 Nm and 56 g product weight. The manufacturer specifies 300 l/min standard nominal flow, also listed for a QS-6 arrangement, providing exact flow and installation data without assigning the ratings of a different MPA valve size.

Problem Solved

Dual normally open functions consolidate pneumatic branch control in one compact valve position, while the published mounting and flow data characterize the selected component for station integration.

10 mm valve 300 l/min nominal 0.25 Nm mounting limit
Select your currency