Sale!

Festo 8049054 Vacuum Generator with Pressure Sensor

Original price was: USD 174.20.Current price is: USD 150.28.

Compact vacuum ejector with 21 l/min atmospheric suction flow, 92% maximum vacuum, electric ejector pulse and programmable PNP/NPN pressure sensing.

SKU Festo-8049054 Category
Festo Vacuum Generators

Festo OVEL-10-H-15-PQ-VQ6-UA-C-A-V1PNLK-H3 Vacuum Generator

BrandFesto
Model IdentifierOVEL-10-H-15-PQ-VQ6-UA-C-A-V1PNLK-H3
Official Part Number8049054

Technical Overview

The Festo OVEL-10-H-15-PQ-VQ6-UA-C-A-V1PNLK-H3 combines compressed-air vacuum generation, electric on/off control and an electrical ejector pulse in a 92 g T-shaped unit. Its 0.95 mm Laval nozzle provides up to 21 l/min suction flow against atmosphere and a maximum vacuum of 92%, with separate supply-pressure conditions specified for those maxima. An integrated piezoresistive sensor measures −1 to 0 bar and provides switchable PNP/NPN output, a two-digit LED indication and settings through IO-Link, teach-in or buttons. QS-6 supply and vacuum connections, an open silencer and a 2.5 m sensor cable define the interfaces for a compact handling circuit.

High-vacuum QS-6 ejector with electrical vacuum and pulse control, 21 l/min atmospheric suction flow and programmable pressure sensing.

Key Features

  • 0.95 mm Laval nozzle; high-vacuum ejector characteristic
  • 21 l/min maximum suction flow against atmosphere at 4 bar supply
  • 92% maximum vacuum at 3.8 bar supply
  • Integrated electrical ejector pulse, flow control and electric on/off valve
  • Piezoresistive pressure sensing over −1 to 0 bar
  • Switchable PNP/NPN output and NC/NO switching element function
  • Two-digit LED indication; IO-Link, teach-in and button settings
  • QS-6 compressed-air and vacuum connections; integrated open silencer
  • 24 V DC coil rated 1.0 W; 21.6–26.4 V DC valve operating range
  • 92 g product weight, IP40 protection and 0–50 °C ambient range

Combine vacuum generation, an electrical release pulse and programmable vacuum feedback in one 92 g QS-6 handling unit.

Technical Specification Matrix

ParameterValue
Nominal size, Laval nozzle0.95 mm
Mounting grid pitch15 mm
Silencer designOpen
Mounting positionAny
Ejector characteristicHigh vacuum; Standard
Grade of filtration40 µm
Manual overrideNon-detenting
Integrated functionEjector pulse, electrical; Flow control; Pressure sensor; On/off valve, electric; Filter; Open silencer
DesignT-shape
Switching element functionNC or NO, switchable
Switching functionFreely programmable
Valve functionClosed
Measurement methodPiezoresistive pressure sensor with display
Display typeLED indicator; 2 digits
Setting optionsIO-Link®; Teach-in; Via display and buttons
Operating pressure for max. suction flow rate0.4 MPa; 4 bar; 58 psi
Operating pressure0.2 MPa...0.7 MPa; 2 bar...7 bar; 29 psi...101.5 psi
Operating pressure for max. vacuum0.38 MPa; 3.8 bar; 55.1 psi
Max. vacuum92 %
Nominal operating pressure0.4 MPa; 4 bar; 58 psi
Max. suction flow rate against atmosphere21 l/min
Air supply time at nominal operating pressure with ejector pulse1 s
Operational voltage range DC21.6 V...26.4 V
Duty cycle100%
Switching outputPNP/NPN, switchable
Characteristic coil data24 V DC: 1.0 W
Approvalc UL us - Listed (Oil)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature0 °C...50 °C
Sound pressure level at nominal operating pressure68 dB(A)
Degree of protectionIP40
Ambient temperature0 °C...50 °C
Physical Weight (kg)0.092
Operating voltage range, DC sensor18 V...30 V
Pressure measuring range-0.1 MPa...0 MPa; -1 bar...0 bar; -14.5 psi...0 psi
Electrical connection input, functionEjector pulse; Vacuum generation
Electrical connection input, connection type2x plugs
Electrical connection input, connector systemPlug pattern H
Electrical connection input, number of connections/cores2
Input electrical connection, mounting typeSnap-locking
Electrical connection output, functionSensor
Electrical connection output, connection typeCable
Electrical connection output, connector systemOpen end
Electrical connection output, number of connections/cores3
Cable characteristicSuitable for energy chains
Cable diameter2.9 mm
Cable diameter tolerance± 0.1 mm
Cable length2.5 m
Nominal cross section conductor0.14 mm²
Type of mountingWith through-hole
Pneumatic connection, port 1For tubing outside diameter of 6 mm
Pneumatic connection, port 3Open silencer
Vacuum connectionFor tubing O.D. 6 mm
Cable sheath colourGrey
Material connecting threadPOM
Note on materialsRoHS compliant
Material sealsNBR
Material receiver nozzlePOM
Material filterPOM
Material housingReinforced PA
Material cable sheathPVC
Material adjusting screwSteel
Material screwsSteel
Material transmitter nozzleWrought aluminium alloy

Industrial Applications

1. Local Vacuum Supply for a Handling Head

A pick-and-place head needs a vacuum source close to its suction circuit. This unit converts compressed air through a 0.95 mm Laval nozzle and connects to the head through a QS-6 vacuum port. Its documented 21 l/min maximum atmospheric suction flow and 92% maximum vacuum describe the available ejector characteristics under their respective supply-pressure conditions.

Problem Solved

The integrated ejector provides a compact local vacuum source, allowing the handling circuit to use a defined pneumatic interface and documented flow and vacuum characteristics.

21 l/min atmospheric suction 92% maximum vacuum QS-6

2. Controlled Part Release at a Placement Station

A placement station must end vacuum generation and command a release pulse after depositing a component. The integrated electric on/off valve and electrical ejector-pulse function provide these two circuit actions at the generator. Built-in flow control provides an adjustment within the same assembly, while the separate electrical input functions identify vacuum generation and ejector pulse for the machine sequence.

Problem Solved

Electrical control of generation and ejector pulse supplies distinct handling and release actions from the same unit, supporting a defined transition from holding to placement.

Electrical ejector pulse Electric on/off valve Flow control

3. Vacuum-Level Feedback for Sequence Control

A handling machine needs vacuum-level feedback to coordinate its pneumatic sequence with measured conditions at the generator. The integrated piezoresistive sensor covers −1 to 0 bar and offers programmable switching with PNP/NPN selection. Operators can view the two-digit LED indication and configure settings through IO-Link, teach-in or the display buttons rather than relying only on an open-loop vacuum command.

Problem Solved

Integrated pressure measurement and programmable switching provide vacuum-condition feedback to the control sequence, while local indication makes the measured condition accessible at the machine.

−1 to 0 bar sensing PNP/NPN IO-Link settings