Sale!

Festo 526780 Pressure Gauge, 0–0.25 MPa, R1/4, Size 50

Original price was: USD 40.82.Current price is: USD 35.88.

Single-MPa-scale Bourdon gauge with accuracy class 2.5, centred rear R1/4 connection, 75 g weight and IP43 protection for inert gas or neutral fluids.

SKU Festo-526780 Category
Festo Pressure Gauge

Festo MA-50-0,25-R1/4-MPA-E-RG Pressure Gauge

BrandFesto
Model IdentifierMA-50-0,25-R1/4-MPA-E-RG
Official Part Number526780

Technical Overview

The Festo MA-50-0,25-R1/4-MPA-E-RG is a size 50 Bourdon-tube pressure gauge with a single outer MPa scale covering 0–0.25 MPa. It conforms to EN 837-1 and measurement accuracy class 2.5, with a centred rear R1/4 connection for inline installation. The 75 g instrument uses brass wetted components, a black ABS housing and a PLEXIGLAS screen. It is specified for inert gases and neutral fluids, excluding oxygen and acetylene, within −20 to 60 °C media and ambient limits. IP43 protection and a 0.66 alternating load factor characterize the enclosure and fluctuating-pressure service conditions.

Size 50 Bourdon-tube pressure gauge with 0–0.25 MPa single scale, accuracy class 2.5 and centred rear R1/4 connection.

Key Features

  • 0–0.25 MPa indicating range on a single outer MPa scale
  • Size 50 Bourdon-tube pressure gauge
  • EN 837-1 conformity and measurement accuracy class 2.5
  • Centred rear R1/4 connection for inline installation
  • 0–2.5 bar equivalent operating-pressure range
  • Inert gas and neutral-fluid media; excludes oxygen and acetylene
  • Brass wetted components and screwed plug
  • Black ABS housing and PLEXIGLAS screen
  • IP43 protection and −20 to 60 °C ambient/media range
  • 75 g product weight and 0.66 alternating load factor

Read 0–0.25 MPa directly at an inert-gas or neutral-fluid circuit through a size 50 mechanical gauge with rear R1/4 connection.

Technical Specification Matrix

ParameterValue
Indicating range0 MPa...0.25 MPa
Conforms to standardEN 837-1
Nominal size of pressure gauge50
Explosion protectionThe information in the certificate must be observed!; Zone 1 (ATEX); Zone 2 (ATEX); Zone 21 (ATEX); Zone 22 (ATEX)
DesignBourdon tube pressure gauge
Type of mountingInline installation
Operating mediumInert gas; Neutral fluids
Note on operating and pilot mediumNo acetylene; No oxygen
Operating pressure0 MPa...0.25 MPa; 0 bar...2.5 bar; 0 psi...36.25 psi
Alternating load factor0.66
Measurement accuracy class2.5
Degree of protectionIP43
Media temperature-20 °C...60 °C
Ambient temperature-20 °C...60 °C
LABS (PWIS) conformityVDMA24364-B1/B2-L
Note on materialsRoHS compliant
Position of connectionCentred, rear
Pneumatic connectionR1/4
Material in contact with the mediumBrass
Material screwed plugBrass
Material housingABS
Material screenPLEXIGLAS®
Housing colourBlack
Physical Weight (kg)0.075
ScaleSingle scale; MPa (outer scale)

Industrial Applications

1. Local Inert-Gas Regulator Adjustment

A workstation sets an inert-gas regulator before beginning a process run. The centred rear R1/4 connection places this gauge at the regulated branch, where its 0–0.25 MPa dial shows pressure as the operator changes the setting. The Bourdon-tube mechanism supplies local indication, with accuracy class 2.5 defining the instrument class for that adjustment task.

Problem Solved

Direct local indication gives the operator pressure feedback while adjusting an inert-gas regulator, avoiding reliance on an unobserved regulator position as the process setting.

0–0.25 MPa Inert gas R1/4 rear connection

2. Neutral-Fluid Transfer-Line Pressure Indication

A machine transferring a neutral fluid needs an accessible indication of discharge pressure during startup. The gauge is specified for neutral fluids and uses brass wetted components, with a 0–0.25 MPa indicating range. Inline installation and the rear R1/4 connection place the measurement at the line, while the −20 to 60 °C media limit defines the allowable fluid-temperature range.

Problem Solved

An inline mechanical gauge makes fluid-line pressure visible at the machine, helping operators observe startup conditions within the instrument's documented media, pressure and temperature limits.

Neutral fluids Brass wetted parts −20 to +60 °C media

3. Observing Pressure Retention in an Isolated Branch

During maintenance, a technician observes pressure in an isolated inert-gas branch after charging it within the gauge range. The mechanical dial provides a local pressure indication without an electrical measurement connection. Its single MPa scale and accuracy class 2.5 define how the observed pressure can be recorded and compared over time; small leakage rates are not quantified by this indication alone.

Problem Solved

Local mechanical indication makes the isolated branch pressure visible during a maintenance observation, giving technicians a consistent MPa reading to record as the condition changes.

Single MPa scale Bourdon-tube indication Class 2.5