1. Local Air Enable at a Workstation
An operator needs to open or close the air feed to a pneumatic workstation at the point of use. The directly operated 2/2 valve provides maintained open and closed states without a pilot-air or electrical command. The R1/8 and QS-6 ports link the component to 6 mm tubing, while threaded or through-hole mounting places that manual control near the workstation.
Problem Solved
A maintained manual state supplies a local air-feed command, allowing the operator to control the selected workstation branch through a simple two-port pneumatic connection.
Manual actuation
2/2 bistable
R1/8 to QS-6
2. Manual Disconnection of a Test-volume Feed
A pneumatic test fixture first charges a volume, then needs the operator to close its feed path for the next process step. The valve's two-port shut-off function interrupts that path without selecting an exhaust connection. Its bistable mechanism maintains the chosen position, and the documented 279.9 l/min nominal flow characterizes the component during the open charging condition.
Problem Solved
Two-port shut-off interrupts the charging path while avoiding an intentional exhaust route through the valve, providing a maintained connection state for the fixture's controlled sequence.
Two-port shut-off
Maintained state
279.9 l/min nominal
3. Manual Switching of a Vacuum Branch
A vacuum fixture requires a local open/close control in its tubing connection. This valve's −0.95 to 10 bar operating range includes negative pressure, and reversible flow permits either direction through the open passage. Direct manual actuation changes the connection state independently of pilot pressure, while the NBR seals and reinforced-PBT housing form the documented valve construction.
Problem Solved
Direct manual switching provides a local control point in the vacuum branch, with documented negative-pressure operation and reversible flow defining the supported connection conditions.
−0.95 bar range limit
Reversible flow
Direct operation