Sale!

Festo 8086607 PROFINET Interface, CPX-AP-I, 100 Mbit/s

Original price was: USD 499.46.Current price is: USD 429.00.

CPX-AP-I interface with dual D-coded M12 PROFINET ports, two AP system outputs, 80-module capacity, 24 V DC power and IP65/IP67 protection.

Festo Remote I/O and Network Interface Components

Festo CPX-AP-I-PN-M12 PROFINET Interface

BrandFesto
Model IdentifierCPX-AP-I-PN-M12
Official Part Number8086607

Technical Overview

The Festo CPX-AP-I-PN-M12 connects an AP automation system to PROFINET IRT or RT through two four-pin D-coded M12 sockets at 100 Mbit/s. Two four-pin D-coded M8 sockets provide AP system communication outputs, with support for up to 80 modules and address volumes of 1024 bytes each for inputs and outputs. GSDML-file configuration and bus diagnostics support controller integration and fault reporting. Nominal 24 V DC electronics/sensor and load circuits use separate M8 power input and forwarding connections, with up to 2 × 4 A requiring external fusing. The 186 g interface has IP65/IP67 protection when unused connections are sealed, and operates over −20 to 60 °C.

100 Mbit/s PROFINET interface for CPX-AP-I with dual M12 network ports, two M8 AP outputs, 80-module capacity and IP65/IP67 protection.

Key Features

  • PROFINET IRT and RT at 100 Mbit/s with electrical isolation
  • Two four-pin D-coded M12x1 fieldbus sockets
  • Two four-pin D-coded M8x1 AP system communication outputs
  • Maximum 80 modules; 1024-byte input and 1024-byte output address volumes
  • GSDML-file configuration support
  • Network, module, system and power diagnostics via LEDs and bus
  • Nominal 24 V DC electronics/sensor and load supplies with ±25% tolerance
  • M8 power input and forwarding; maximum 2 × 4 A with external fusing
  • IP65/IP67 protection with unused connections sealed; −20 to 60 °C ambient range
  • 186 g product weight; 170 × 45 × 35 mm length × width × height

Link up to 80 AP modules to PROFINET through an IP65/IP67 interface with network and module diagnostics.

Technical Specification Matrix

ParameterValue
Type of mountingOn DIN rail via accessories; With through-hole
Max. number of modules80
Physical Weight (kg)0.186
Ambient temperature-20 °C...60 °C
Storage temperature-40 °C...70 °C
Relative air humidity5 - 95%; Non-condensing
Degree of protectionIP65; IP67
Note on degree of protectionUnused connections sealed
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Pollution degree2
Max. cable length50 m system communication
Note on max. cable lengthPower supply according to nominal voltage
LABS (PWIS) conformityVDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14Element installed statically, no meaningful evaluation possible according; to ISO 14644-1
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
KC markKC-EMV
ApprovalRCM; c UL us - Listed (Oil)
Certificate issuing authorityUL E239998
Note on materialsRoHS compliant
Material housingPA; Makrolon®; Nickel-plated die-cast zinc
Material o-ringFluoro rubber
Diagnostics via LEDDiagnostics per module; Network error; Power supply, electronics/sensors; Load power supply; System diagnostics; Maintenance required
Diagnostics via busAPDD invalid; Switch-off load supply; Communication with AP module interrupted; Electronics/sensors overvoltage; Load overvoltage; Electronics/sensors undervoltage; Load undervoltage
Diagnostics per internal communicationModule error; Output short circuit/overload; Short circuit/overload in sensor supply; Load supply undervoltage
Fieldbus interfaceEthernet
Field bus, protocolPROFINET IRT; PROFINET RT
Field bus, connection type2x socket
Field bus, connection systemM12x1, D-coded to EN 61076-2-101
Field bus, connection pattern4
Field bus interface, electrical isolationYes
Field bus interface, transmission rate100 Mbit/s
Max. address volume, inputs1024 Byte
Max. address volume, outputs1024 Byte
Configuration supportGSDML file
Communication interface, functionSystem communication XF20 OUT / XF21 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, protocolAP
Communication interface, screenedYes
Power supply, functionIncoming electronics/sensors and load
Power supply, connection typePlug
power supply, connection systemM8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires4
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Note regarding operating voltageSELV/PELV fixed power supplies required; Note the voltage drop
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load±25%
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors±25%
Max. power supply2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 80 mA
Intrinsic current consumption at nominal operating voltage loadTypically 5 mA
Power failure bridging10 ms
Reverse polarity protectionYes
Dimensions L x W x H (cm)17 x 4.5 x 3.5

Industrial Applications

1. PROFINET Connection for a Modular Machine Station

A machine controller using PROFINET needs to exchange process data with a CPX-AP-I station. The interface provides 100 Mbit/s communication through two D-coded M12 sockets and supports GSDML-file configuration. Its maximum input and output address volumes of 1024 bytes each define the documented process-data capacity for integrating the selected AP modules into the controller project.

Problem Solved

The interface bridges the controller's PROFINET connection to the AP system, providing a documented network connector arrangement, configuration method and process-data address capacity for the station.

PROFINET 100 Mbit/s GSDML configuration

2. Distributed AP Module Connections near the Process

A modular machine needs AP communication connections close to its process equipment while maintaining a PROFINET link to the controller. Two M8 AP system outputs provide the local communication interfaces, with support for up to 80 modules. Through-hole or accessory DIN-rail mounting and IP65/IP67 protection support the installation, provided unused connections are sealed as the manufacturer specifies.

Problem Solved

AP communication outputs provide a documented connection point for the distributed module arrangement, while sealed connectors and mounting options support locating the interface at the machine.

Two AP outputs Up to 80 modules IP65/IP67 with sealed connections

3. Diagnosing Communication and Power Faults

Maintenance staff need to distinguish a module-communication interruption from an electronics or load-power problem. The interface reports bus diagnostics for interrupted AP communication and overvoltage or undervoltage conditions. LED indications cover network, module, system and power conditions, while internal communication diagnostics include module errors and sensor/output short circuits or overloads for a more specific fault investigation.

Problem Solved

Separate communication and power diagnostics expose the type of fault affecting the AP station, helping maintenance target the relevant module, connection or supply circuit during troubleshooting.

Bus diagnostics Power monitoring Module fault information
Select your currency