Festo 8069572 Vacuum Generator, 21 l/min, Sensor and Ejector Pulse

Original price was: USD 194.74.Current price is: USD 167.70.

High-vacuum ejector with 92% maximum vacuum, 21 l/min maximum suction flow, electric ejector pulse, pressure display, PNP/NPN output and 6 mm ports.

SKU Festo-8069572 Category
Festo Vacuum Generators

Festo OVEL-10-H-15-PQ-VQ6-UA-C-A-B2PNLK-H3 Vacuum Generator

BrandFesto
Model IdentifierOVEL-10-H-15-PQ-VQ6-UA-C-A-B2PNLK-H3
Official Part Number8069572

Technical Overview

The Festo OVEL-10-H-15-PQ-VQ6-UA-C-A-B2PNLK-H3 combines a high-vacuum ejector with an electric on/off valve, electrical ejector pulse, pressure sensor, flow control, filter and open silencer. Its 0.95 mm Laval nozzle provides up to 21 l/min suction flow against atmosphere and 92% maximum vacuum, with those maxima specified at 4 bar and 3.8 bar respectively. The piezoresistive sensor includes a two-digit display, switchable PNP/NPN output and IO-Link setting access. This 92 g T-shaped unit uses 6 mm supply and vacuum connections, separate electrical valve inputs and a three-core sensor cable, with a 2–7 bar operating range and IP40 protection.

High-vacuum generator with 21 l/min maximum suction flow, 92% maximum vacuum, electric release pulse, pressure sensor and 6 mm connections.

Key Features

  • 0.95 mm Laval nozzle with high-vacuum ejector characteristic
  • 21 l/min maximum suction flow against atmosphere at 4 bar operating pressure
  • 92% maximum vacuum at 3.8 bar operating pressure
  • Integrated electric on/off valve, electrical ejector pulse and flow control
  • Piezoresistive pressure sensor with two-digit LED display and −1 to 1 bar measuring range
  • Switchable PNP/NPN output and freely programmable switching function
  • Settings through IO-Link, teach-in or display and buttons
  • 6 mm supply and vacuum connections; integrated filter and open silencer
  • 24 V DC, 1.0 W coil data; 21.6–26.4 V valve operating range and 18–30 V sensor range
  • 92 g product weight, through-hole mounting and IP40 protection

Combine vacuum generation, electrical release pulse and local pressure feedback in one 92 g ejector with 6 mm pneumatic connections.

Technical Specification Matrix

ParameterValue
Nominal size, Laval nozzle0.95 mm
Mounting grid pitch15 mm
Silencer designOpen
Mounting positionAny
Ejector characteristicHigh vacuum; Standard
Grade of filtration40 µm
Manual overrideNon-detenting
Integrated functionEjector pulse, electrical; Flow control; Pressure sensor; On/off valve, electric; Filter; Open silencer
DesignT-shape
Switching element functionNC or NO, switchable
Switching functionFreely programmable
Valve functionClosed
Measurement methodPiezoresistive pressure sensor with display
Display typeLED indicator; 2 digits
Setting optionsIO-Link®; Teach-in; Via display and buttons
Operating pressure for max. suction flow rate0.4 MPa; 4 bar; 58 psi
Operating pressure0.2 MPa...0.7 MPa; 2 bar...7 bar; 29 psi...101.5 psi
Operating pressure for max. vacuum0.38 MPa; 3.8 bar; 55.1 psi
Max. vacuum92 %
Nominal operating pressure0.4 MPa; 4 bar; 58 psi
Max. suction flow rate against atmosphere21 l/min
Air supply time at nominal operating pressure with ejector pulse1 s
Operational voltage range DC21.6 V...26.4 V
Duty cycle100%
Switching outputPNP/NPN, switchable
Characteristic coil data24 V DC: 1.0 W
Approvalc UL us - Listed (Oil)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature0 °C...50 °C
Sound pressure level at nominal operating pressure68 dB(A)
Degree of protectionIP40
Ambient temperature0 °C...50 °C
Physical Weight (kg)0.092
Operating voltage range, DC sensor18 V...30 V
Pressure measuring range-0.1 MPa...0.1 MPa; -1 bar...1 bar; -14.5 psi...14.5 psi
Electrical connection input, functionEjector pulse; Vacuum generation
Electrical connection input, connection type2x plugs
Electrical connection input, connector systemPlug pattern H
Electrical connection input, number of connections/cores2
Input electrical connection, mounting typeSnap-locking
Electrical connection output, functionSensor
Electrical connection output, connection typeCable
Electrical connection output, connector systemOpen end
Electrical connection output, number of connections/cores3
Cable characteristicSuitable for energy chains
Cable diameter2.9 mm
Cable diameter tolerance± 0.1 mm
Cable length2.5 m
Nominal cross section conductor0.14 mm²
Type of mountingWith through-hole
Pneumatic connection, port 1For tubing outside diameter of 6 mm
Pneumatic connection, port 3Open silencer
Vacuum connectionFor tubing O.D. 6 mm
Cable sheath colourGrey
Material connecting threadPOM
Note on materialsRoHS compliant
Material sealsNBR
Material receiver nozzlePOM
Material filterPOM
Material housingReinforced PA
Material cable sheathPVC
Material adjusting screwSteel
Material screwsSteel
Material transmitter nozzleWrought aluminium alloy

Industrial Applications

1. Vacuum Pickup in an Assembly Transfer

An assembly transfer uses a suction gripper to pick up a workpiece with a suitable sealing surface. The generator produces vacuum from compressed air through its 0.95 mm Laval nozzle, while the integrated electric on/off valve controls generation. Its 21 l/min maximum suction flow against atmosphere and 92% maximum vacuum describe separate operating characteristics for the selected pneumatic pickup arrangement.

Problem Solved

The integrated ejector and electrical valve provide a controllable vacuum source at the handling circuit, combining generation and switching without requiring a separate electrically driven vacuum pump.

21 l/min maximum suction 92% maximum vacuum Electric on/off valve

2. Commanded Release at a Placement Station

A vacuum handling station needs to release a workpiece after placing it into a fixture. The generator incorporates an electrically commanded ejector pulse and flow-control function alongside vacuum generation. Separate electrical input functions for the release pulse and vacuum generation allow the machine control sequence to request pickup and release through the documented valve interfaces.

Problem Solved

An integrated electrical ejector pulse provides a commanded release action at the vacuum circuit, while separate control functions distinguish release from ordinary vacuum generation in the placement sequence.

Electrical ejector pulse Integrated flow control Separate valve inputs

3. Vacuum-Level Feedback for a Handling Sequence

A machine needs an electrical indication of the vacuum condition before proceeding with the next handling step. The integrated piezoresistive pressure sensor measures from −1 to 1 bar and provides switchable PNP/NPN output. The two-digit local display shows pressure information, while teach-in, display buttons and IO-Link setting access support configuring the sensing function at the generator.

Problem Solved

Pressure sensing converts the vacuum condition into a switching signal for the machine sequence, with local indication and configurable settings supplied within the same ejector assembly.

−1 to 1 bar sensing PNP/NPN output Two-digit display