Sale!

Festo 8035537 Pressure Sensor, −1 to 1 bar, IO-Link, R1/8

Original price was: USD 81.64.Current price is: USD 70.98.

Pressure sensor with R1/8 male/M5 female port, −1 to 1 bar range, configurable PNP/NPN and analogue outputs, IO-Link V1.1 and illuminated LCD.

SKU Festo-8035537 Category
Festo Pressure Sensors And Vacuum Sensors

Festo SPAN-B2R-R18M-PNLK-PNVBA-L1 Pressure Sensor

BrandFesto
Model IdentifierSPAN-B2R-R18M-PNLK-PNVBA-L1
Official Part Number8035537

Technical Overview

The Festo SPAN-B2R-R18M-PNLK-PNVBA-L1 measures relative pressure from −1 to 1 bar with a piezoresistive element. It offers two configurable PNP/NPN switching outputs, selectable 0–10 V, 1–5 V or 4–20 mA analogue output and IO-Link V1.1 communication. COM2 transfers a 14-bit pressure value and two binary monitoring bits with a 3 ms minimum cycle time. The illuminated LCD, teach-in, buttons and IO-Link support configuration, with PIN-code and IO-Link protection against tampering. The 46 g unit has an R1/8 male/M5 female pneumatic connection, four-contact L1J plug, 15–30 V DC operation and IP40 protection.

−1 to 1 bar pressure sensor with R1/8 male/M5 female connection, IO-Link V1.1, configurable switching/analogue outputs and illuminated LCD.

Key Features

  • Piezoresistive relative-pressure measurement from −1 to 1 bar
  • ±1.5% FS accuracy and ±0.3% FS repetition accuracy
  • Two PNP or two NPN switching outputs with selectable NC/NO function
  • Threshold, window-comparator and auto-difference monitoring
  • Configurable analogue output: 0–10 V, 1–5 V or 4–20 mA
  • IO-Link V1.1, COM2 at 38.4 kBaud and minimum 3 ms cycle time
  • 14-bit pressure measurement and 2-bit binary monitoring in two input-data bytes
  • Illuminated LCD with IO-Link, teach-in and button setting options
  • R1/8 male/M5 female pneumatic connection, four-contact L1J plug and 15–30 V DC supply
  • 46 g product weight with IP40 protection and 0–50 °C ambient/media range

Send pressure measurements through IO-Link while configuring threshold, window or pressure-change monitoring for a −1 to 1 bar pneumatic circuit.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Listed (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Certificate issuing authorityUL E322346
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range-0.1 MPa; -1 bar; -14.5 psi
End value for pressure measuring range0.1 MPa; 1 bar; 14.5 psi
Max. overload pressure5 bar
Overload pressure0.5 MPa; 5 bar; 72.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]; Inert gas
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C...50 °C
Ambient temperature0 °C...50 °C
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator; Threshold value comparator; Auto difference monitoring
Switching element functionNC or NO, switchable
Max. output current100 mA
Analogue output0 - 10 V; 4 - 20 mA; 1 - 5 V
Max. load resistance current output500 Ohm
Min. load resistance voltage output20 kOhm
Short circuit current ratingYes
ProtocolIO-Link®
IO-Link, Protocol versionDevice V 1.1
IO-Link, ProfileSmart sensor profile
IO-Link, Function classesBinary data channel (BDC); Process data variable (PDV); Identification; Diagnostics; Teach channel
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, Port classA
IO-Link, Process data length OUT0 bytes
IO-Link, Process data length IN2 bytes
IO-Link, Process data content IN14 bit PDV (pressure measurement value); 2 bit BDC (pressure monitoring)
IO-Link, Min. cycle time3 ms
IO-Link, Data storage required0.5 KB
Operational voltage range DC15 V...30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemPlug pattern L1J
Electrical connection 1, number of connections/cores4
Type of mountingFront panel mounting; With thread; Via wall/surface bracket
Mounting positionAny
Pneumatic connectionMale thread R1/8; Female thread M5
Physical Weight (kg)0.046
Material housingReinforced PA
Material in contact with the mediumFluoro rubber; High-alloy stainless steel
Display typeIlluminated LCD
Displayable unitsMPa; bar; inH2O; inHg; kPa; kgf/cm²; mbar; mmHg; psi
Setting optionsIO-Link®; Teach-in; Via display and buttons
Protection against tamperingIO-Link®; PIN code
Setting range threshold value0 %...100 %
Setting range hysteresis0 %...90 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Suitability for the production of Li-ion batteriesSuitable for battery production with reduced Cu/Zn/Ni values (F1a)
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1

Industrial Applications

1. Vacuum Pickup Readiness Signal

A suction handling station needs an electrical indication that the measured vacuum has reached the configured pickup threshold. This sensor's −1 to 1 bar relative range includes the vacuum operating region, and its PNP/NPN selection matches different controller input types. The local LCD and teach-in function assist setting the switching level at the handling station.

Problem Solved

A configurable vacuum threshold turns the measured pressure condition into a controller input, supporting pickup-sequence decisions without depending on a technician's local gauge reading.

Vacuum range to −1 bar PNP/NPN Teach-in

2. Regulated-Air Pressure Window Monitoring

An assembly fixture requires its regulated air supply to remain inside a defined operating band. The sensor's window-comparator function evaluates the measured pressure against a configured window rather than a single limit. Its illuminated display provides a local reading during regulator adjustment, while selectable output polarity connects the resulting condition to the machine's input circuit.

Problem Solved

Window comparison identifies when pressure leaves the selected band, giving the controller a useful process-condition signal while the technician retains a local pressure display.

Window comparator Illuminated LCD Up to 1 bar

3. Pressure-Change Monitoring in an Isolated Circuit

A pneumatic test fixture isolates a charged volume and monitors whether its pressure changes during a defined machine sequence. The sensor provides an auto-difference monitoring mode and ±0.3% FS repetition accuracy, allowing the controller to use a pressure-change signal. Isolation, timing and acceptance criteria remain functions of the surrounding test equipment rather than an assumed feature of the sensor.

Problem Solved

Auto-difference monitoring converts a pressure change into a switching condition, supporting detection of an unwanted change in a controlled isolated-volume sequence without manual observation.

Auto-difference monitoring ±0.3% FS repeatability 2 outputs
Select your currency