1. Pneumatic Actuator Flow Adjustment
A compact pneumatic mechanism needs local adjustment of the air flow feeding its actuator circuit. The valve's slotted-head screw changes the throttling setting at the M5-to-QS-3 connection. The 40 l/min standard nominal-flow rating characterises the valve, while actual actuator speed depends on the available pressure, load and surrounding pneumatic connections.
Problem Solved
Adjustable throttling supplies a local means of changing the actuator circuit's air flow, supporting motion tuning through a mechanically set valve at the connection.
Slotted-screw adjustment
40 l/min nominal
M5 / QS-3
2. Process Air-Blast Flow Trimming
A tooling station uses a compressed-air jet for a release or clearing step and needs an adjustable flow setting at the branch connection. The throttle valve provides manual flow control through its slotted-head screw over a 0–10 bar operating range. Its 9 g screw-in assembly places that adjustment at the local M5-to-QS-3 interface.
Problem Solved
A local throttling adjustment changes the air delivered to the jet branch, allowing the process flow setting to be tuned without changing the machine's upstream regulated pressure.
0–10 bar
Manual flow control
9 g
3. Small Pneumatic Volume Charging
A test fixture charges a small pneumatic volume and needs a restriction that adjusts the rate of incoming air. The flow-control function provides a mechanically adjustable restriction using the slotted screw. The specified 40 l/min nominal flow and 0–10 bar operating range define component limits; the volume and changing pressure difference determine the resulting charging time.
Problem Solved
The adjustable restriction changes the incoming air flow during charging, giving the fixture a local tuning element for pressure-rise behaviour as the volume approaches the available supply pressure.
Adjustable restriction
40 l/min nominal
0–10 bar